High Temperature Limit Switch with Top Plunger

$148.15
There are two types of high temperature top plunger limit switch, one has a sealed top ball plunger and the other has a sealed top plunger without ball. The top plunger can reset automatically. High temperature limit switch can be used in the environment temperature 350℃ (622℉). The rated current and voltage are customizable, such as 10A/120VAC, 2A/48VDC, etc. The default value is 5A/220VAC. It also has fully enclosed 1NO + 1NC contact switches, which is casting from high temperature resistant material.
SKU: ATO-HTLS-TP
*
Free Shipping
Delivery date: 6-12 days

High temperature limit switch has two types of top plunger, with contact type 1NO + 1NC and rated current/voltage 5A/220VAC. It operates reliably in high-humidity environments with a humidity tolerance of <95%RH.

Specification

ModelATO-HTLS-XWKEATO-HTLS-XWKF
Weight258g
Shape of top plunger *Top plunger without ballTop ball plunger
Rated voltage220VAC (Customizable rated voltage is shown in the reference table below.)
Rated current5A (Customizable rated current is shown in the reference table below.)
Contact type1NO+1NC (NC pin: 1 & 2, NO pin: 3 & 4)
Operating speed1mm/s~2m/s
Operating frequencyMachinery: 120 times/minute
Electric: 30 times/minute
Contact resistance<15MΩ, initial stage
Insulation resistance>100MΩ (<500VDC)
Withstand voltageBetween no-connection terminals: 1000VAC, 50/60Hz lasts 1 minute
Between the terminal and the contact: 2000VAC, 50/60Hz lasts 1 minute
Between terminal and no-load current metal: 2200VAC, 50/60Hz lasts 1 minute
VibrationMisoperation endurance: 10~55Hz, 1.5mm, double-amplitude
ImpactMechanical endurance: >1000m/s2 (>100G)
Misoperation endurance: >300m/s2 (>30G)
Shell materialCast aluminum alloy
Temperature-10~+350℃ (14~622℉)
Humidity<95%RH
Working lifeMachinery: >15million times
Electric: >0.5million times
Protection classIP66


Reference table for customizable rated voltage and rated current

Rated voltageRated current (A)
Non-inductive loadInductive load
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125VAC1031.51052
250VAC521531.0
480VAC31.50.831.50.8
600VAC110.51.510.5
8VDC1063106
14VDC1063106
30VDC64364
125VDC0.80.20.20.80.2
250VDC0.40.10.10.40.1

Note:

  1. Power factor of inductive load is above 0.4 (AC). The time constant is below 7ms (DC).
  2. The inrush current of lamp load is 10 times that of steady state current, and the inrush current of motor load is 6 times that of steady state current.

Dimension (unit: mm)

High temperature limit switch with top plunger dimension
Note: In the diagram, OP means operation position, at which the external force is applied to the drive lever to make the movable contact just operating from the state of the free position. PT means pretravel, the distance the drive rod moves from the free position to the operation position. The total travel position TTP is approx 5.8mm.

Tips: 6 mechanical considerations for limit switches

  1. To ensure a high degree of reliability, limit switch must be used within a suitable contact force range.
  2. When using normally closed circuit (NC), the setting of the operating object must ensure that the actuator can return to the free position. In addition, when using normally open circuit (NO), the actuator must be pressed to 70~100% of the specified value of the over travel (OT) (60~80% of the total travel (TT)) in order to absorb minute oscillations and errors.
  3. If the stroke is set near the operating position (OP) and return position (RP), it may cause contact instability. In addition, if it is setting at the total travel position (TTP), the actuator and built-in switch may be damaged due to the inertia of the operating object, so adjust the stroke using the mounting plate and the operating object.
  4. If the actuator is often in pressed condition, it will cause initial failure and poor reset. Please maintain and replace it regularly.
  5. About the mechanical conditions at the time of limit switch selection - The actuator must be selected according to the operation mode. Please confirm the operating speed and operating frequency.
    1. When the operation speed is extremely slow, the switching of the contacts will be unstable, which may cause problems such as poor contact or welding.
    2. When the operation speed is extremely fast, and the impact force of the action may destroy the switch. If the frequency is too high, the contacts may not be able to switch in time, so please do not use it beyond the specified frequency.
  6. Please do not apply excessive force to the drive rod. Damage or poor activity may result. Set the stroke within the appropriate range for each model. Use beyond the range, may break the limit switch.

VFD Emergency Stop with Limit Switches

In this video, you will learn about the setup and operation of emergency stopping a motor by using limit switches and a variable frequency drive (VFD). By combining the limit switches of the emergency stop function with the VFD GK3000, a strong safety measure can be established that can quickly stop the motor operation in an emergency.

Automatic Material Trolley Control with Limit Switch

In this video, the method of applying limit switches to automatic material trolley control is demonstrated.

Roller Limit Switch NO NC Contact Wiring and Detection

In this video, the roller limit switch NO NC contact wiring and detection operation are shown.

Product reviews
High temperature limit switch with meticulous packaging
5
Turbodelta
Avatar
8/12/2021 11:53 PM
This high temperature limit switch was delivered at the specified time, packed carefully, and the item was not damaged at all. I am very satisfied with it and will continue to buy it in the future.
Was this review helpful? Yes No (0/0)
Component Purchase
5
Selby
Avatar
11/10/2025 12:16 AM
We purchased 2 ATO-HTLS-XWKE units and now need an ATO-HTLS-RL. Can we just purchase the "header" of the RL and install it into our existing device?
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, the 2 ATO-HTLS-XWKE units you purchased have a different structure than the ATO-HTLS-RL. You cannot directly purchase the "header" of the RL and install it into your existing device. We recommend purchasing the ATO-HTLS-RL separately.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High temperature limit switch has two types of top plunger, with contact type 1NO + 1NC and rated current/voltage 5A/220VAC. It operates reliably in high-humidity environments with a humidity tolerance of <95%RH.

Specification

ModelATO-HTLS-XWKEATO-HTLS-XWKF
Weight258g
Shape of top plunger *Top plunger without ballTop ball plunger
Rated voltage220VAC (Customizable rated voltage is shown in the reference table below.)
Rated current5A (Customizable rated current is shown in the reference table below.)
Contact type1NO+1NC (NC pin: 1 & 2, NO pin: 3 & 4)
Operating speed1mm/s~2m/s
Operating frequencyMachinery: 120 times/minute
Electric: 30 times/minute
Contact resistance<15MΩ, initial stage
Insulation resistance>100MΩ (<500VDC)
Withstand voltageBetween no-connection terminals: 1000VAC, 50/60Hz lasts 1 minute
Between the terminal and the contact: 2000VAC, 50/60Hz lasts 1 minute
Between terminal and no-load current metal: 2200VAC, 50/60Hz lasts 1 minute
VibrationMisoperation endurance: 10~55Hz, 1.5mm, double-amplitude
ImpactMechanical endurance: >1000m/s2 (>100G)
Misoperation endurance: >300m/s2 (>30G)
Shell materialCast aluminum alloy
Temperature-10~+350℃ (14~622℉)
Humidity<95%RH
Working lifeMachinery: >15million times
Electric: >0.5million times
Protection classIP66


Reference table for customizable rated voltage and rated current

Rated voltageRated current (A)
Non-inductive loadInductive load
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125VAC1031.51052
250VAC521531.0
480VAC31.50.831.50.8
600VAC110.51.510.5
8VDC1063106
14VDC1063106
30VDC64364
125VDC0.80.20.20.80.2
250VDC0.40.10.10.40.1

Note:

  1. Power factor of inductive load is above 0.4 (AC). The time constant is below 7ms (DC).
  2. The inrush current of lamp load is 10 times that of steady state current, and the inrush current of motor load is 6 times that of steady state current.

Dimension (unit: mm)

High temperature limit switch with top plunger dimension
Note: In the diagram, OP means operation position, at which the external force is applied to the drive lever to make the movable contact just operating from the state of the free position. PT means pretravel, the distance the drive rod moves from the free position to the operation position. The total travel position TTP is approx 5.8mm.

Tips: 6 mechanical considerations for limit switches

  1. To ensure a high degree of reliability, limit switch must be used within a suitable contact force range.
  2. When using normally closed circuit (NC), the setting of the operating object must ensure that the actuator can return to the free position. In addition, when using normally open circuit (NO), the actuator must be pressed to 70~100% of the specified value of the over travel (OT) (60~80% of the total travel (TT)) in order to absorb minute oscillations and errors.
  3. If the stroke is set near the operating position (OP) and return position (RP), it may cause contact instability. In addition, if it is setting at the total travel position (TTP), the actuator and built-in switch may be damaged due to the inertia of the operating object, so adjust the stroke using the mounting plate and the operating object.
  4. If the actuator is often in pressed condition, it will cause initial failure and poor reset. Please maintain and replace it regularly.
  5. About the mechanical conditions at the time of limit switch selection - The actuator must be selected according to the operation mode. Please confirm the operating speed and operating frequency.
    1. When the operation speed is extremely slow, the switching of the contacts will be unstable, which may cause problems such as poor contact or welding.
    2. When the operation speed is extremely fast, and the impact force of the action may destroy the switch. If the frequency is too high, the contacts may not be able to switch in time, so please do not use it beyond the specified frequency.
  6. Please do not apply excessive force to the drive rod. Damage or poor activity may result. Set the stroke within the appropriate range for each model. Use beyond the range, may break the limit switch.
Product reviews
High temperature limit switch with meticulous packaging
5
Turbodelta
Avatar
8/12/2021 11:53 PM
This high temperature limit switch was delivered at the specified time, packed carefully, and the item was not damaged at all. I am very satisfied with it and will continue to buy it in the future.
Was this review helpful? Yes No (0/0)
Component Purchase
5
Selby
Avatar
11/10/2025 12:16 AM
We purchased 2 ATO-HTLS-XWKE units and now need an ATO-HTLS-RL. Can we just purchase the "header" of the RL and install it into our existing device?
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, the 2 ATO-HTLS-XWKE units you purchased have a different structure than the ATO-HTLS-RL. You cannot directly purchase the "header" of the RL and install it into your existing device. We recommend purchasing the ATO-HTLS-RL separately.
Only registered users can write reviews
Customers who bought this item also bought

High Temperature Limit Switch with Roller Plunger

ATO-HTLS-RP
$148.15
There are two types of roller plunger limit switch, the roller direction of the one is parallel to the mounting surface, and the other is perpendicular to the mounting surface. Roller plunger has automatic reset function. It is also high temperature limit switch with the fully enclosed 1NO + 1NC contact switches casting from high temperature resistant material. It can be used in the environment temperature 350℃ (622℉) and without being damaged by oxidation or pollution. The default rated current and voltage is 5A/220VAC. Other values are customizable, such as 3A/480VAC, 0.8A/120VDC, etc.

High Temperature Limit Switch with Adjustable Roller Lever

ATO-HTLS-ARL
$148.15
High temperature limit switch adopts fully enclosed 1NO + 1NC contact switches, can be used in the environment temperature 350℃ (622℉). Its roller lever has the adjustable radius of 25-89mm to meet the needs of more occasions. Adjustable roller lever limit switch also has automatic reset function. The default rated current and voltage is 5A/220VAC, and other values (AC 120V/380V, DC 12V/24V/48V)can be customizable.