High temperature limit switch has two types of top plunger, with contact type 1NO + 1NC and rated current/voltage 5A/220VAC. It operates reliably in high-humidity environments with a humidity tolerance of <95%RH.
Specification
| Model | ATO-HTLS-XWKE | ATO-HTLS-XWKF | |
| Weight | 258g | ||
| Shape of top plunger * | Top plunger without ball | Top ball plunger | |
| Rated voltage | 220VAC (Customizable rated voltage is shown in the reference table below.) | ||
| Rated current | 5A (Customizable rated current is shown in the reference table below.) | ||
| Contact type | 1NO+1NC (NC pin: 1 & 2, NO pin: 3 & 4) | ||
| Operating speed | 1mm/s~2m/s | ||
| Operating frequency | Machinery: 120 times/minute Electric: 30 times/minute | ||
| Contact resistance | <15MΩ, initial stage | ||
| Insulation resistance | >100MΩ (<500VDC) | ||
| Withstand voltage | Between no-connection terminals: 1000VAC, 50/60Hz lasts 1 minute Between the terminal and the contact: 2000VAC, 50/60Hz lasts 1 minute Between terminal and no-load current metal: 2200VAC, 50/60Hz lasts 1 minute | ||
| Vibration | Misoperation endurance: 10~55Hz, 1.5mm, double-amplitude | ||
| Impact | Mechanical endurance: >1000m/s2 (>100G) Misoperation endurance: >300m/s2 (>30G) | ||
| Shell material | Cast aluminum alloy | ||
| Temperature | -10~+350℃ (14~622℉) | ||
| Humidity | <95%RH | ||
| Working life | Machinery: >15million times Electric: >0.5million times | ||
| Protection class | IP66 | ||
Reference table for customizable rated voltage and rated current
| Rated voltage | Rated current (A) | |||||||
| Non-inductive load | Inductive load | |||||||
| Resistive load | Lamp load | Inductive load | Motor load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
| 125VAC | 10 | 3 | 1.5 | 10 | 5 | 2 | ||
| 250VAC | 5 | 2 | 1 | 5 | 3 | 1.0 | ||
| 480VAC | 3 | 1.5 | 0.8 | 3 | 1.5 | 0.8 | ||
| 600VAC | 1 | 1 | 0.5 | 1.5 | 1 | 0.5 | ||
| 8VDC | 10 | 6 | 3 | 10 | 6 | |||
| 14VDC | 10 | 6 | 3 | 10 | 6 | |||
| 30VDC | 6 | 4 | 3 | 6 | 4 | |||
| 125VDC | 0.8 | 0.2 | 0.2 | 0.8 | 0.2 | |||
| 250VDC | 0.4 | 0.1 | 0.1 | 0.4 | 0.1 | |||
Note:
- Power factor of inductive load is above 0.4 (AC). The time constant is below 7ms (DC).
- The inrush current of lamp load is 10 times that of steady state current, and the inrush current of motor load is 6 times that of steady state current.
Dimension (unit: mm)

Note: In the diagram, OP means operation position, at which the external force is applied to the drive lever to make the movable contact just operating from the state of the free position. PT means pretravel, the distance the drive rod moves from the free position to the operation position. The total travel position TTP is approx 5.8mm.
Tips: 6 mechanical considerations for limit switches
- To ensure a high degree of reliability, limit switch must be used within a suitable contact force range.
- When using normally closed circuit (NC), the setting of the operating object must ensure that the actuator can return to the free position. In addition, when using normally open circuit (NO), the actuator must be pressed to 70~100% of the specified value of the over travel (OT) (60~80% of the total travel (TT)) in order to absorb minute oscillations and errors.
- If the stroke is set near the operating position (OP) and return position (RP), it may cause contact instability. In addition, if it is setting at the total travel position (TTP), the actuator and built-in switch may be damaged due to the inertia of the operating object, so adjust the stroke using the mounting plate and the operating object.
- If the actuator is often in pressed condition, it will cause initial failure and poor reset. Please maintain and replace it regularly.
- About the mechanical conditions at the time of limit switch selection - The actuator must be selected according to the operation mode. Please confirm the operating speed and operating frequency.
- When the operation speed is extremely slow, the switching of the contacts will be unstable, which may cause problems such as poor contact or welding.
- When the operation speed is extremely fast, and the impact force of the action may destroy the switch. If the frequency is too high, the contacts may not be able to switch in time, so please do not use it beyond the specified frequency.
- Please do not apply excessive force to the drive rod. Damage or poor activity may result. Set the stroke within the appropriate range for each model. Use beyond the range, may break the limit switch.
Product reviews
High temperature limit switch with meticulous packaging
Turbodelta
8/12/2021 11:53 PM
This high temperature limit switch was delivered at the specified time, packed carefully, and the item was not damaged at all. I am very satisfied with it and will continue to buy it in the future.
Was this review helpful? (0/0)
Component Purchase
Selby
11/10/2025 12:16 AM
We purchased 2 ATO-HTLS-XWKE units and now need an ATO-HTLS-RL. Can we just purchase the "header" of the RL and install it into our existing device?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
High Temperature Limit Switch with Roller Plunger
ATO-HTLS-RP
$148.15
There are two types of roller plunger limit switch, the roller direction of the one is parallel to the mounting surface, and the other is perpendicular to the mounting surface. Roller plunger has automatic reset function. It is also high temperature limit switch with the fully enclosed 1NO + 1NC contact switches casting from high temperature resistant material. It can be used in the environment temperature 350℃ (622℉) and without being damaged by oxidation or pollution. The default rated current and voltage is 5A/220VAC. Other values are customizable, such as 3A/480VAC, 0.8A/120VDC, etc.
High Temperature Limit Switch with Adjustable Roller Lever
ATO-HTLS-ARL
$148.15
High temperature limit switch adopts fully enclosed 1NO + 1NC contact switches, can be used in the environment temperature 350℃ (622℉). Its roller lever has the adjustable radius of 25-89mm to meet the needs of more occasions. Adjustable roller lever limit switch also has automatic reset function. The default rated current and voltage is 5A/220VAC, and other values (AC 120V/380V, DC 12V/24V/48V)can be customizable.