High temperature limit switch has adjustable roller lever with radius of 25-89mm, contact type 1NO + 1NC and rated current/voltage 5A/220VAC. It has an IP66 protection rating, is highly dust and water resistant, and can operate reliably in harsh environments such as high-temperature industrial processes and outdoor installations.
Specification
| Model | ATO-HTLS-XWKB |
| Weight | 258g |
| Adjustable radius of roller lever | 25-89mm |
| Rated voltage | 220VAC (other voltage is shown in the reference table below.) |
| Rated current | 5A (other rated current is shown in the reference table below.) |
| Contact type | 1NO+1NC (NC pin: 1 & 2, NO pin: 3 & 4) |
| Operating speed | 1mm/s~2m/s |
| Operating frequency | Machinery: 120 times/minute Electric: 30 times/minute |
| Contact resistance | <15MΩ, initial stage |
| Insulation resistance | >100MΩ (<500VDC) |
| Withstand voltage | Between no-connection terminals: 1000VAC, 50/60Hz lasts 1 minute Between the terminal and the contact: 2000VAC, 50/60Hz lasts 1 minute Between terminal and no-load current metal: 2200VAC, 50/60Hz lasts 1 minute |
| Vibration | Misoperation endurance: 10~55Hz, 1.5mm, double-amplitude |
| Bottom terminal thread size | M20*1.5mm |
| Impact | Mechanical endurance: >1000m/s2 (>100G) Misoperation endurance: >300m/s2 (>30G) |
| Shell material | Cast aluminum alloy |
| Temperature | -10~+350℃ (14~622℉) |
| Humidity | <95%RH |
| Working life | Machinery: >15million times Electric: >0.5million times |
| Protection class | IP66 |
Reference table for rated voltage and rated current
| Rated voltage | Rated current (A) | |||||||
| Non-inductive load | Inductive load | |||||||
| Resistive load | Lamp load | Inductive load | Motor load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
| 125VAC | 10 | 3 | 1.5 | 10 | 5 | 2 | ||
| 250VAC | 5 | 2 | 1 | 5 | 3 | 1.0 | ||
| 480VAC | 3 | 1.5 | 0.8 | 3 | 1.5 | 0.8 | ||
| 600VAC | 1 | 1 | 0.5 | 1.5 | 1 | 0.5 | ||
| 8VDC | 10 | 6 | 3 | 10 | 6 | |||
| 14VDC | 10 | 6 | 3 | 10 | 6 | |||
| 30VDC | 6 | 4 | 3 | 6 | 4 | |||
| 125VDC | 0.8 | 0.2 | 0.2 | 0.8 | 0.2 | |||
| 250VDC | 0.4 | 0.1 | 0.1 | 0.4 | 0.1 | |||
Note:
- Power factor of inductive load is above 0.4 (AC). The time constant is below 7ms (DC).
- The inrush current of lamp load is 10 times that of steady state current, and the inrush current of motor load is 6 times that of steady state current.
Dimension (unit: mm)

Tips: Regular inspection and regular replacement of limit switches
- If the switching frequency is low (less than 1 time/day) in the state of being pressed all the time, there is a possibility that the reset may fail due to the deterioration of the parts. Please confirm in advance and check regularly.
- In addition to the mechanical life and electrical life described in the performance column, the high temperature limit switch life is also related to the deterioration of each part due to the usage environment (especially the deterioration of rubbers & resins, the corrosion of metal parts, etc). Therefore, please check and replace regularly to prevent accidents.
- When ON/OFF is not set for a long time, the contact reliability may be reduced due to oxidation or other reasons. Poor connection will cause accident hazard.
- Install the limit switch securely and in a clean place that is easy to inspect and can be replaced.
- Install an action indicator light in the places where inspection and maintenance are difficult and in dark places.
Product reviews
High temperature limit switch can be delivered on time
Coulson
8/15/2021 8:50 PM
This high temperature limit switch with adjustable roller lever can be delivered on time. I ordered it and delivered it within a day. If you are in a hurry to use it, I strongly recommend buying it from ATO.com.
Was this review helpful? (0/0)
Can the operating head for the limit switch be bought separately from the body as a spare part?
Jakko
8/2/2022 2:23 AM
Can the operating head for the limit switch be bought separately from the body as a spare part? My client wanted to know this. In the future if the operating head breaks and the body is functional, they would just change the operating head. The limit switch is situated in very tight and inaccessible place that the easier repair method is to change the operating head itself.
Was this review helpful? (0/0)
Voltage usage
Charlene
7/24/2026 12:56 AM
Do I need to order an ATO-HTLS-ARL with a different voltage? What is its applicable voltage?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
High Temperature Limit Switch with Roller Lever
ATO-HTLS-RL
$148.15
High temperature limit switch adopts one roller lever with a radius of 38mm and fully enclosed 1NO + 1NC contact switches casting from high temperature resistant material, can be used in the environment temperature 350℃ (622℉) and without being damaged by oxidation or pollution. The default rated current and voltage is 5A/220VAC. Customizable voltage is DC 0-220V and AC 0-480V. Roller lever limit switch has automatic reset function. It is usually used for the machinery operating at a low speed.
High Temperature Limit Switch with Roller Plunger
ATO-HTLS-RP
$148.15
There are two types of roller plunger limit switch, the roller direction of the one is parallel to the mounting surface, and the other is perpendicular to the mounting surface. Roller plunger has automatic reset function. It is also high temperature limit switch with the fully enclosed 1NO + 1NC contact switches casting from high temperature resistant material. It can be used in the environment temperature 350℃ (622℉) and without being damaged by oxidation or pollution. The default rated current and voltage is 5A/220VAC. Other values are customizable, such as 3A/480VAC, 0.8A/120VDC, etc.
High Temperature Limit Switch with Adjustable Rod Lever
ATO-HTLS-ARDL
$148.15
High temperature limit switch has a rod lever with adjustable length from 25mm to 140mm. The internal contact switches 1NO + 1NC are casting from high temperature resistant material. So limit switch can be used in the 350℃ (622℉) high temperature occasion, such as coal mine machinery, vertical pit furnace, etc. Adjustable rod lever limit switch has automatic reset function. The default rated current and voltage is 5A/220VAC, other AC/DC voltage can be designed according to customer's requirement.
High Temperature Limit Switch with Top Plunger
ATO-HTLS-TP
$148.15
There are two types of high temperature top plunger limit switch, one has a sealed top ball plunger and the other has a sealed top plunger without ball. The top plunger can reset automatically. High temperature limit switch can be used in the environment temperature 350℃ (622℉). The rated current and voltage are customizable, such as 10A/120VAC, 2A/48VDC, etc. The default value is 5A/220VAC. It also has fully enclosed 1NO + 1NC contact switches, which is casting from high temperature resistant material.