High temperature limit switch has rod lever with adjustable length of 25-140mm, contact type 1NO + 1NC and rated current/voltage 5A/220VAC. Its mechanical life is more than 15 million times and its electrical life is more than 500,000 times, which can be used for a long time.
Specification
| Model | ATO-HTLS-XWKI |
| Weight | 258g |
| Adjustable length of rod lever | 25-140mm |
| Rated voltage | 220VAC (Customizable rated voltage is shown in the reference table below.) |
| Rated current | 5A (Customizable rated current is shown in the reference table below.) |
| Contact type | 1NO+1NC (NC pin: 1 & 2, NO pin: 3 & 4) |
| Operating speed | 1mm/s~2m/s |
| Operating frequency | Machinery: 120 times/minute Electric: 30 times/minute |
| Contact resistance | <15MΩ, initial stage |
| Insulation resistance | >100MΩ (<500VDC) |
| Withstand voltage | Between no-connection terminals: 1000VAC, 50/60Hz lasts 1 minute Between the terminal and the contact: 2000VAC, 50/60Hz lasts 1 minute Between terminal and no-load current metal: 2200VAC, 50/60Hz lasts 1 minute |
| Vibration | Misoperation endurance: 10~55Hz, 1.5mm, double-amplitude |
| Impact | Mechanical endurance: >1000m/s2 (>100G) Misoperation endurance: >300m/s2 (>30G) |
| Shell material | Cast aluminum alloy |
| Temperature | -10~+350℃ (14~622℉) |
| Humidity | <95%RH |
| Working life | Machinery: >15million times Electric: >0.5million times |
| Protection class | IP66 |
Reference table for customizable rated voltage and rated current
| Rated voltage | Rated current (A) | |||||||
| Non-inductive load | Inductive load | |||||||
| Resistive load | Lamp load | Inductive load | Motor load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
| 125VAC | 10 | 3 | 1.5 | 10 | 5 | 2 | ||
| 250VAC | 5 | 2 | 1 | 5 | 3 | 1.0 | ||
| 480VAC | 3 | 1.5 | 0.8 | 3 | 1.5 | 0.8 | ||
| 600VAC | 1 | 1 | 0.5 | 1.5 | 1 | 0.5 | ||
| 8VDC | 10 | 6 | 3 | 10 | 6 | |||
| 14VDC | 10 | 6 | 3 | 10 | 6 | |||
| 30VDC | 6 | 4 | 3 | 6 | 4 | |||
| 125VDC | 0.8 | 0.2 | 0.2 | 0.8 | 0.2 | |||
| 250VDC | 0.4 | 0.1 | 0.1 | 0.4 | 0.1 | |||
Note:
- Power factor of inductive load is above 0.4 (AC). The time constant is below 7ms (DC).
- The inrush current of lamp load is 10 times that of steady state current, and the inrush current of motor load is 6 times that of steady state current.
Dimension (unit: mm)

Tips: 4 considerations of limit switches
- Please do not connect a power source of different polarity or different type to the contact of one limit switch.
- Please do not apply voltage between contacts during circuit design (may cause contact melting).
- Even in the event of an abnormal situation, there should be no short circuit (may lead to fusing of conductive parts).
- Limit switches used in electronic circuits (low voltage and low current).
- If the vibration and tremor of the contacts cause problems, please take the following measures.
- Insert the integrating circuit.
- The pulse caused by vibration and chatter shall be controlled below the disturbance tolerance of the load.
- In the fields with particularly high contact reliability requirements, the original silver contacts are not suitable. The performance of limit switches for small voltages and currents with gold contacts is better.
- In consideration of safety, Use b for the limit switch for emergency stop.
To prevent damage to the limit switch caused by a short circuit, connect a momentary fuse with a breaking current value equivalent to 1.5 to 2 times the rated current in series with the switch. When using EN certified ratings, use a 10A fuse gT or gG suitable for IEC60269.
- If the vibration and tremor of the contacts cause problems, please take the following measures.
Customers who bought this item also bought
High Temperature Limit Switch with Adjustable Roller Lever
ATO-HTLS-ARL
$148.15
High temperature limit switch adopts fully enclosed 1NO + 1NC contact switches, can be used in the environment temperature 350℃ (622℉). Its roller lever has the adjustable radius of 25-89mm to meet the needs of more occasions. Adjustable roller lever limit switch also has automatic reset function. The default rated current and voltage is 5A/220VAC, and other values (AC 120V/380V, DC 12V/24V/48V)can be customizable.
High Temperature Limit Switch with Roller Plunger
ATO-HTLS-RP
$148.15
There are two types of roller plunger limit switch, the roller direction of the one is parallel to the mounting surface, and the other is perpendicular to the mounting surface. Roller plunger has automatic reset function. It is also high temperature limit switch with the fully enclosed 1NO + 1NC contact switches casting from high temperature resistant material. It can be used in the environment temperature 350℃ (622℉) and without being damaged by oxidation or pollution. The default rated current and voltage is 5A/220VAC. Other values are customizable, such as 3A/480VAC, 0.8A/120VDC, etc.
High Temperature Limit Switch with Coil Spring
ATO-HTLS-CS
$148.15
High temperature coil spring limit switch has spring top diameter 6.5mm or 1.2mm, can be used for micromotion detecting. The coil spring also has automatic reset function. The default rated current and voltage is 5A/220VAC. Other values can be customizable like AC 120 volt, AC 380 volt, DC 12 volt, DC 48 volt, etc. High temperature limit switch with coil spring has fully enclosed 1NO + 1NC contact switches can be used in the environment temperature 350℃ (622℉).