High Temperature Limit Switch with Roller Plunger

$148.15
There are two types of roller plunger limit switch, the roller direction of the one is parallel to the mounting surface, and the other is perpendicular to the mounting surface. Roller plunger has automatic reset function. It is also high temperature limit switch with the fully enclosed 1NO + 1NC contact switches casting from high temperature resistant material. It can be used in the environment temperature 350℃ (622℉) and without being damaged by oxidation or pollution. The default rated current and voltage is 5A/220VAC. Other values are customizable, such as 3A/480VAC, 0.8A/120VDC, etc.
SKU: ATO-HTLS-RP
*
Free Shipping
Delivery date: 6-12 days

High temperature limit switch has two types of roller plunger, with contact type 1NO + 1NC and rated current/voltage 5A/220VAC. It has an IP66 protection rating, has strong dust and water resistance, and can operate reliably in harsh environments.

Specification

ModelATO-HTLS-XWKCATO-HTLS-XWKD
Weight258g
Roller direction *Parallel to the mounting surfacePerpendicular to the mounting surface
Rated voltage220VAC (Customizable rated voltage is shown in the reference table below.)
Rated current5A (Customizable rated current is shown in the reference table below.)
Contact type1NO+1NC (NC pin: 1 & 2, NO pin: 3 & 4)
Operating speed1mm/s~2m/s
Operating frequencyMachinery: 120 times/minute
Electric: 30 times/minute
Contact resistance<15MΩ, initial stage
Insulation resistance>100MΩ (<500VDC)
Withstand voltageBetween no-connection terminals: 1000VAC, 50/60Hz lasts 1 minute
Between the terminal and the contact: 2000VAC, 50/60Hz lasts 1 minute
Between terminal and no-load current metal: 2200VAC, 50/60Hz lasts 1 minute
VibrationMisoperation endurance: 10~55Hz, 1.5mm, double-amplitude
ImpactMechanical endurance: >1000m/s2 (>100G)
Misoperation endurance: >300m/s2 (>30G)
Shell materialCast aluminum alloy
Temperature-10~+350℃ (14~622℉)
Humidity<95%RH
Working lifeMachinery: >15million times
Electric: >0.5million times
Protection classIP66


Reference table for customizable rated voltage and rated current

Rated voltageRated current (A)
Non-inductive loadInductive load
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125VAC1031.51052
250VAC521531.0
480VAC31.50.831.50.8
600VAC110.51.510.5
8VDC1063106
14VDC1063106
30VDC64364
125VDC0.80.20.20.80.2
250VDC0.40.10.10.40.1

Note:

  1. Power factor of inductive load is above 0.4 (AC). The time constant is below 7ms (DC).
  2. The inrush current of lamp load is 10 times that of steady state current, and the inrush current of motor load is 6 times that of steady state current.

Operating Characteristics

ModelATO-HTLS-XWKCATO-HTLS-XWKD
OF (Max.)2720g2720g
RF (Min.)910g910g
PT (Max.)1.7mm1.7mm
OT (Min.)5.6mm5.6mm
MD (Max.)1mm1mm
OP44±0.8mm44±0.8mm


Dimension (unit: mm)

High temperature limit switch with roller plunger dimension
Note: In the diagram, OP means operation position, at which the external force is applied to the drive lever to make the movable contact just operating from the state of the free position. PT means pretravel, the distance the drive rod moves from the free position to the operation position.

Tips: Testing before installing limit switch

When actually using the limit switch, unexpected problems may occur. Therefore, testing before installation should be done to the extent possible.
In the test, not only the load conditions but also the use environment must be tested under the same conditions as the actual use state.
Each rated performance value described in the catalog is the value under the following conditions unless otherwise specified.

  • Inductive load: power factor above 0.4 (AC).
  • Time constant 7ms or less (DC).
  • Solenoid: Inrush current is 10~20 times of constant current.
  • Lamp load: Inrush current is 10~15 times of constant current.
  • Motor load: Inrush current is 5~10 times of constant current.
  • Relay: Inrush current is 4~5 times of constant current.

The use environment:

  1. Ambient temperature: -10~+350℃
  2. Ambient humidity: 40~ 70%RH

Note that inductive loads are particularly problematic in DC circuits, so it is necessary to fully understand the value of the load's time constant (L/R).

VFD Emergency Stop with Limit Switches

In this video, you will learn about the setup and operation of emergency stopping a motor by using limit switches and a variable frequency drive (VFD). By combining the limit switches of the emergency stop function with the VFD GK3000, a strong safety measure can be established that can quickly stop the motor operation in an emergency.

Automatic Material Trolley Control with Limit Switch

In this video, the method of applying limit switches to automatic material trolley control is demonstrated.

Roller Limit Switch NO NC Contact Wiring and Detection

In this video, the roller limit switch NO NC contact wiring and detection operation are shown.

Product reviews
Related parameters of high temperature limit switch
5
Arturo
Avatar
7/14/2021 9:04 PM
What is tripping travel of your high temperature limit switch?
Was this review helpful? Yes No (0/0)
ATO Responded
Tripping travel: ±5 degrees.
Made Of
5
kaan
Avatar
1/6/2026 11:25 PM
Inside of switch (terminal side) what is it made of? Is it some kind of metal or seramic? Can you give some more details about it?
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, you can contact our sales team for more information at sales@ato.com.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High temperature limit switch has two types of roller plunger, with contact type 1NO + 1NC and rated current/voltage 5A/220VAC. It has an IP66 protection rating, has strong dust and water resistance, and can operate reliably in harsh environments.

Specification

ModelATO-HTLS-XWKCATO-HTLS-XWKD
Weight258g
Roller direction *Parallel to the mounting surfacePerpendicular to the mounting surface
Rated voltage220VAC (Customizable rated voltage is shown in the reference table below.)
Rated current5A (Customizable rated current is shown in the reference table below.)
Contact type1NO+1NC (NC pin: 1 & 2, NO pin: 3 & 4)
Operating speed1mm/s~2m/s
Operating frequencyMachinery: 120 times/minute
Electric: 30 times/minute
Contact resistance<15MΩ, initial stage
Insulation resistance>100MΩ (<500VDC)
Withstand voltageBetween no-connection terminals: 1000VAC, 50/60Hz lasts 1 minute
Between the terminal and the contact: 2000VAC, 50/60Hz lasts 1 minute
Between terminal and no-load current metal: 2200VAC, 50/60Hz lasts 1 minute
VibrationMisoperation endurance: 10~55Hz, 1.5mm, double-amplitude
ImpactMechanical endurance: >1000m/s2 (>100G)
Misoperation endurance: >300m/s2 (>30G)
Shell materialCast aluminum alloy
Temperature-10~+350℃ (14~622℉)
Humidity<95%RH
Working lifeMachinery: >15million times
Electric: >0.5million times
Protection classIP66


Reference table for customizable rated voltage and rated current

Rated voltageRated current (A)
Non-inductive loadInductive load
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125VAC1031.51052
250VAC521531.0
480VAC31.50.831.50.8
600VAC110.51.510.5
8VDC1063106
14VDC1063106
30VDC64364
125VDC0.80.20.20.80.2
250VDC0.40.10.10.40.1

Note:

  1. Power factor of inductive load is above 0.4 (AC). The time constant is below 7ms (DC).
  2. The inrush current of lamp load is 10 times that of steady state current, and the inrush current of motor load is 6 times that of steady state current.

Operating Characteristics

ModelATO-HTLS-XWKCATO-HTLS-XWKD
OF (Max.)2720g2720g
RF (Min.)910g910g
PT (Max.)1.7mm1.7mm
OT (Min.)5.6mm5.6mm
MD (Max.)1mm1mm
OP44±0.8mm44±0.8mm


Dimension (unit: mm)

High temperature limit switch with roller plunger dimension
Note: In the diagram, OP means operation position, at which the external force is applied to the drive lever to make the movable contact just operating from the state of the free position. PT means pretravel, the distance the drive rod moves from the free position to the operation position.

Tips: Testing before installing limit switch

When actually using the limit switch, unexpected problems may occur. Therefore, testing before installation should be done to the extent possible.
In the test, not only the load conditions but also the use environment must be tested under the same conditions as the actual use state.
Each rated performance value described in the catalog is the value under the following conditions unless otherwise specified.

  • Inductive load: power factor above 0.4 (AC).
  • Time constant 7ms or less (DC).
  • Solenoid: Inrush current is 10~20 times of constant current.
  • Lamp load: Inrush current is 10~15 times of constant current.
  • Motor load: Inrush current is 5~10 times of constant current.
  • Relay: Inrush current is 4~5 times of constant current.

The use environment:

  1. Ambient temperature: -10~+350℃
  2. Ambient humidity: 40~ 70%RH

Note that inductive loads are particularly problematic in DC circuits, so it is necessary to fully understand the value of the load's time constant (L/R).

Product reviews
Related parameters of high temperature limit switch
5
Arturo
Avatar
7/14/2021 9:04 PM
What is tripping travel of your high temperature limit switch?
Was this review helpful? Yes No (0/0)
ATO Responded
Tripping travel: ±5 degrees.
Made Of
5
kaan
Avatar
1/6/2026 11:25 PM
Inside of switch (terminal side) what is it made of? Is it some kind of metal or seramic? Can you give some more details about it?
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, you can contact our sales team for more information at sales@ato.com.
Only registered users can write reviews
Customers who bought this item also bought

High Temperature Limit Switch with Adjustable Roller Lever

ATO-HTLS-ARL
$148.15
High temperature limit switch adopts fully enclosed 1NO + 1NC contact switches, can be used in the environment temperature 350℃ (622℉). Its roller lever has the adjustable radius of 25-89mm to meet the needs of more occasions. Adjustable roller lever limit switch also has automatic reset function. The default rated current and voltage is 5A/220VAC, and other values (AC 120V/380V, DC 12V/24V/48V)can be customizable.

Custom Order

ATO-CUSTOM
Pay for custom orders, or extra amount of existing orders.
Indicate the item specification you pay for, and specify PI / PO number if you have.

High Temperature Limit Switch with Roller Lever

ATO-HTLS-RL
$148.15
High temperature limit switch adopts one roller lever with a radius of 38mm and fully enclosed 1NO + 1NC contact switches casting from high temperature resistant material, can be used in the environment temperature 350℃ (622℉) and without being damaged by oxidation or pollution. The default rated current and voltage is 5A/220VAC. Customizable voltage is DC 0-220V and AC 0-480V. Roller lever limit switch has automatic reset function. It is usually used for the machinery operating at a low speed.

High Temperature Limit Switch with Adjustable Rod Lever

ATO-HTLS-ARDL
$148.15
High temperature limit switch has a rod lever with adjustable length from 25mm to 140mm. The internal contact switches 1NO + 1NC are casting from high temperature resistant material. So limit switch can be used in the 350℃ (622℉) high temperature occasion, such as coal mine machinery, vertical pit furnace, etc. Adjustable rod lever limit switch has automatic reset function. The default rated current and voltage is 5A/220VAC, other AC/DC voltage can be designed according to customer's requirement.

High Temperature Limit Switch with Top Plunger

ATO-HTLS-TP
$148.15
There are two types of high temperature top plunger limit switch, one has a sealed top ball plunger and the other has a sealed top plunger without ball. The top plunger can reset automatically. High temperature limit switch can be used in the environment temperature 350℃ (622℉). The rated current and voltage are customizable, such as 10A/120VAC, 2A/48VDC, etc. The default value is 5A/220VAC. It also has fully enclosed 1NO + 1NC contact switches, which is casting from high temperature resistant material.