Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 to 100/500/1000 ppm

$734.87
Fixed nitrogen dioxide (NO2) gas detectors for detecting NO2 concentrations for sale, with optional measuring ranges from 0 to 100/500/1000 ppm. The NO2 leak detector has audible and visual gas alarm and data display functions, a unique infrared control function, which can control the equipment non-contactly, the signal output is optional 4-20mA and RS485, and the explosion-proof design is fast, reliable, and stable.
SKU: GD300-NO2
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

High-quality fixed nitrogen dioxide gas detectors with self-calibration and zero calibration functions, make the detection more accurate and reliable. Measuring ranges of 0-20, 0-50, 0-100, 0-500, 0-1000ppm, with temperature compensation for gas concentration under condensing conditions. The infrared controller can remotely control the gas alarm setting, and the gas leak detector can output one or two switching signals, which can drive the ventilator or solenoid valve and other external devices. Adopting original overseas gas sensors, it is compatible with various controlled alarms, PLC, DCS, and other control systems, and can be remotely monitored.

Features

  • Adopting high precision sensor for accurate gas leak detection.
  • Equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • Compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • With self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • Can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-NO2
Detection PrincipleElectrochemistry
GasNitrogen Dioxide (NO2)
Range (Optional)0 to 1ppm, 0 to 5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 500ppm, 0 to 1000ppm
Resolution0.001ppm(0-1/5ppm), 0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm) 1ppm (0-500/1000ppm)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12-36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Stainless steel
  • Input Range of Pressure Gauge: 0-25MPa
  • Output Range of Pressure Gauge: 0-0.6Mpa
  • Gauge Class: 2.5
  • Input Pressure: ≤15MPa
  • Output Pressure: ≤0.45MPa
  • Rated Flow: 0.6 m3/h
  • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

  1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
  2. Working temperature is -20°C to +50°C.
  3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
  4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
  5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Ammonia (NH3) Gas Detector Details

Tips: Fixed Nitrogen Dioxide (NO2) Gas Detector Working Principle

  1. Chemical or Electrochemical Sensors: Fixed NO2 gas detectors typically use chemical or electrochemical gas sensors as the core component to detect the presence and change in concentration of NO2 gas.
  2. Gas Sampling: Gas leak detectors typically introduce a sample of ambient air into the gas sensor via a gas sampling system. This can be accomplished through a pumping system, pump, or other sampling device.
  3. Potential Measurement: Once NO2 gas enters the sensor, a catalytic reaction at the working electrode causes a change in potential. The electrode circuitry measures this potential change and converts it into an electrical signal.
  4. Signal Processing and Data Output: Gas tester typically include signal processing circuitry to amplify, filter and stabilize the signal obtained from the sensor. Finally, the gas detector outputs the measured NO2 concentration data in digital form, usually presented to the user via a display, data logging system, communications interface, etc.
  5. Calibration: To ensure accurate measurements, fixed NO2 gas detectors usually require periodic calibration. This can be done by using a known concentration of calibration gas.

Gas Detector 3-Wire System

In the realm of gas detection systems, the 3-wire configuration offers a robust wiring solution, especially for applications requiring analog output. This video will show you the 3-wire gas detector wiring.

Gas Detector 4-Wire System

The wiring of the 4-wire gas detector supports the RS485 interface Modbus RTU communication mode. This video will show you the 4-wire gas detector wiring.

Using Cloud Data and 4G for Fixed Gas Detectors

This video will show you about the applications of cloud data and 4G transmission for fixed gas detectors.

Monitoring Combustible Gas in Pipelines

This video will show you how to monitoring combustible gas in pipelines.

Fixed Gas Detector Remote Integrated Control

In this video, the process of remote integrated control of a fixed gas detector is introduced.

How to Calibrate a Fixed Gas Detector?

This video introduces the zero calibration process of a fixed gas detector. When the air is clean, press the menu first, then press the "+" key to enter F04, then press the OK key, and then press the BACK key. The detected data will become zero. Prepare the standard gas, we use isobutane for calibration.

Step 1: Press the menu, then press the "+" key to enter F07, change the data to the same as the standard gas value, and press OK.
Step 2: Press the menu, then press the "+" key to enter F08, now you will see it shows 0, change it to 1, and then press the OK key to return.
Step 3: Connect the sensor to the standard gas, the gas flow rate is 500mL/min, and press the OK key after the data stabilizes.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High-quality fixed nitrogen dioxide gas detectors with self-calibration and zero calibration functions, make the detection more accurate and reliable. Measuring ranges of 0-20, 0-50, 0-100, 0-500, 0-1000ppm, with temperature compensation for gas concentration under condensing conditions. The infrared controller can remotely control the gas alarm setting, and the gas leak detector can output one or two switching signals, which can drive the ventilator or solenoid valve and other external devices. Adopting original overseas gas sensors, it is compatible with various controlled alarms, PLC, DCS, and other control systems, and can be remotely monitored.

Features

  • Adopting high precision sensor for accurate gas leak detection.
  • Equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • Compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • With self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • Can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-NO2
Detection PrincipleElectrochemistry
GasNitrogen Dioxide (NO2)
Range (Optional)0 to 1ppm, 0 to 5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 500ppm, 0 to 1000ppm
Resolution0.001ppm(0-1/5ppm), 0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm) 1ppm (0-500/1000ppm)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12-36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Stainless steel
  • Input Range of Pressure Gauge: 0-25MPa
  • Output Range of Pressure Gauge: 0-0.6Mpa
  • Gauge Class: 2.5
  • Input Pressure: ≤15MPa
  • Output Pressure: ≤0.45MPa
  • Rated Flow: 0.6 m3/h
  • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

  1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
  2. Working temperature is -20°C to +50°C.
  3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
  4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
  5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Ammonia (NH3) Gas Detector Details

Tips: Fixed Nitrogen Dioxide (NO2) Gas Detector Working Principle

  1. Chemical or Electrochemical Sensors: Fixed NO2 gas detectors typically use chemical or electrochemical gas sensors as the core component to detect the presence and change in concentration of NO2 gas.
  2. Gas Sampling: Gas leak detectors typically introduce a sample of ambient air into the gas sensor via a gas sampling system. This can be accomplished through a pumping system, pump, or other sampling device.
  3. Potential Measurement: Once NO2 gas enters the sensor, a catalytic reaction at the working electrode causes a change in potential. The electrode circuitry measures this potential change and converts it into an electrical signal.
  4. Signal Processing and Data Output: Gas tester typically include signal processing circuitry to amplify, filter and stabilize the signal obtained from the sensor. Finally, the gas detector outputs the measured NO2 concentration data in digital form, usually presented to the user via a display, data logging system, communications interface, etc.
  5. Calibration: To ensure accurate measurements, fixed NO2 gas detectors usually require periodic calibration. This can be done by using a known concentration of calibration gas.
Only registered users can write reviews
Customers who bought this item also bought

Fixed Ozone (O3) Gas Detector, 0 to 1/5/10/20/50/100 ppm

GD300-O3
$869.43
Reliable manufacturer Ozone gas detector for sale. Available measuring range 0-1/5/10/20/50/100 ppm, sound and light alarm by remote control, output signal 4-20mA and RS485, high accuracy 3% F.S, fast response within 10s. O3 gas concentration detector is fixed mounting, small size, compact structure, competitive price.

Fixed Phosphine (PH3) Gas Detector, 0 to 100/1000/3000 ppm

GD300-PH3
$779.89
Selling a PH3 phosphine gas detector with an alarm light at a low price. This is a wall-mounted explosion-proof gas detector with a measuring range of 0 to 100/1000/3000 ppm. It can work continuously for 24 hours and is powered by 12-24V DC, the gas detector has a connection distance of 1000m, and the protection level is IP65.

Fixed Nitric Oxide (NO) Gas Detector, 0 to 250/500/1000 ppm

GD300-NO
$689.99
The exclusive discounted nitric oxide gas detector provides highly accurate measurements for sale. The built-in alarm system ensures you know the NO concentration in the environment promptly. The measurement range is 0~250ppm, 0~500ppm, and 0~1000ppm to choose from, which is highly reliable. Characteristic, high stability nitric oxide detector, real-time display, output signal 4-20mA & RS485 optional.

Fixed Benzene (C6H6) Gas Detector, 0 to 10/100/200/1000/10000 ppm

GD300-C6H6
$1,765.79
Buy favorable price fixed Benzene (C6H6) gas detector online, with advanced sensor, measuring ranges of 0-1/10/50/100/200/1000/2000/5000/10000ppm. This C6H6 gas monitor with sound & light alarm is a safey device that monitor and alert individuals to the presence of Benzene gas in industrial, laboratory, or commercial settings.

Portable Benzene (C6H6) Gas Detector, 0 to 500/2000/5000/10000 ppm

GD200-C6H6
$1,589.52
Portable Benzene gas detector is a single gas monitor used in industrial safety, environmental monitoring, and emergency response to detect and measure C6H6 levels in the air. Compact handheld C6H6 detector has high-precision sensor and sound and light alarm and optional 0 to 1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm.