Fixed Carbon Monoxide (CO) Gas Detector, 0 to 100/500/1000 ppm

$486.77
Fixed CO gas detector monitors the carbon monoxide concentration and sounds the alarm with remote control, selectable measuring range 0-100ppm, 0-500ppm, 0-1000ppm or 0-2000ppm. CO gas detector has signal output 4-20mA and RS485. Compact design, high accuracy, fast response, high reliability and favorable price.
SKU: GD300-CO
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

Carbon monoxide (CO) gas detector is fixed design to monitor the CO gas leak in range of 0 to 100/500/1000/2000 ppm for 24 hours in the confined space or pipeline and gives sound and light alarm.

Features

  • Adopting high precision sensor for accurate gas leak detection.
  • Equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • Compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • With self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • Can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-CO
Detection PrincipleElectrochemistry
GasCarbon Monoxide (CO)
Range (Optional)0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 500ppm, 0 to 1000ppm, 0 to 2000ppm
Resolution0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm), 1ppm (0-500/1000/2000ppm)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12-36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

  1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
  2. Working temperature is -20°C to +50°C.
  3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
  4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
  5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Carbon Monoxide (CO) Gas Detector Details

Tips: Working Principle of Gas Detector Sensors

  1. Electrochemical Sensors
    Due to the active chemical properties, the testing gases generally have reducibility or oxidizability. Electrons are released or absorbed in the chemical reactions and a large number of electrons form a current. The current is proportional to the gas concentration, thus the gas concentration is obtained by measuring the current.
  2. Catalytic Combustion Sensors
    It works based on the principle that the heat is released from the combustion reaction of a surface combustible gas, namely combustion increases the temperature of the platinum wire coil and thus the resistance of the coil increases. The gas concentration is obtained by measuring the resistance value change of platinum wire. It’s suitable for measuring low concentration combustible gas.
  3. PID Photo Ion Sensors
    High energy ultraviolet rays ionize the organic gases, and then amplify the current of charged ions on the plate to measure. The current value reflects the gas concentration.
  4. Infrared Sensors
    Different combustible gas has different absorption ability to infrared ray. The concentration of combustible gas can be measured by detecting the current on the infrared photosensitive component.
  5. Semiconductor Sensor
    Due to the absorbability of semiconducting materials on gas, change the resistance value of the gas sensitive resistance to judge the existence of gas.

Gas Detector 3-Wire System

In the realm of gas detection systems, the 3-wire configuration offers a robust wiring solution, especially for applications requiring analog output. This video will show you the 3-wire gas detector wiring.

Gas Detector 4-Wire System

The wiring of the 4-wire gas detector supports the RS485 interface Modbus RTU communication mode. This video will show you the 4-wire gas detector wiring.

Using Cloud Data and 4G for Fixed Gas Detectors

This video will show you about the applications of cloud data and 4G transmission for fixed gas detectors.

Monitoring Combustible Gas in Pipelines

This video will show you how to monitoring combustible gas in pipelines.

Fixed Gas Detector Remote Integrated Control

In this video, the process of remote integrated control of a fixed gas detector is introduced.

How to Calibrate a Fixed Gas Detector?

This video introduces the zero calibration process of a fixed gas detector. When the air is clean, press the menu first, then press the "+" key to enter F04, then press the OK key, and then press the BACK key. The detected data will become zero. Prepare the standard gas, we use isobutane for calibration.

Step 1: Press the menu, then press the "+" key to enter F07, change the data to the same as the standard gas value, and press OK.
Step 2: Press the menu, then press the "+" key to enter F08, now you will see it shows 0, change it to 1, and then press the OK key to return.
Step 3: Connect the sensor to the standard gas, the gas flow rate is 500mL/min, and press the OK key after the data stabilizes.

Product reviews
Works so good.
5
Marcel
Avatar
12/18/2018 6:56 PM
We bought this carbon monoxide detector as we have to monitor the CO exposure in the well. The detector arrived in time and was easy to install. So far, the detector gave us twice alarming. Works so good.
Was this review helpful? Yes No (0/0)
CO gas detector resolution
5
Jerry
Avatar
3/30/2020 6:54 PM
I’m looking for a fixed CO gas detector for my basement. I need 0-500ppm measuring range and I want to know what the resolution of your detector is in this range.
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, my friend. The resolution of 0-500ppm is 0.1ppm.
Essential Safety Partner
5
Jocob
Avatar
8/30/2023 7:47 PM
The Fixed Carbon Monoxide (CO) Gas Detector has become my ultimate safety companion. With its precise detection range from 0 to 1000 ppm, I feel a sense of security like never before. This device's unwavering vigilance against the silent threat of CO ensures that my surroundings are continuously monitored.
Was this review helpful? Yes No (0/0)
Recommended Gas Detector
5
Ephraim
Avatar
8/21/2025 9:13 PM
We are looking for single- and multi-gas flowmeters with data loggers for analyzing carbon monoxide, carbon dioxide, hydrogen, methane, ethane, and higher concentrations. Please advise on the options. This will be used to analyze battery thermal runaway gases.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Please tell us whether you prefer a portable or fixed gas detector. If you want 24/7 monitoring, a fixed gas detector is required.
2. Please tell us the concentrations of the gases you are measuring: CO, CO2, H2, CH4, C2H4, and C2H2. In particular, CO and H2 can interfere with each other, so we need the concentrations of these gases to recommend a suitable model.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Carbon monoxide (CO) gas detector is fixed design to monitor the CO gas leak in range of 0 to 100/500/1000/2000 ppm for 24 hours in the confined space or pipeline and gives sound and light alarm.

Features

  • Adopting high precision sensor for accurate gas leak detection.
  • Equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • Compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • With self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • Can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-CO
Detection PrincipleElectrochemistry
GasCarbon Monoxide (CO)
Range (Optional)0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 500ppm, 0 to 1000ppm, 0 to 2000ppm
Resolution0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm), 1ppm (0-500/1000/2000ppm)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12-36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

  1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
  2. Working temperature is -20°C to +50°C.
  3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
  4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
  5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Carbon Monoxide (CO) Gas Detector Details

Tips: Working Principle of Gas Detector Sensors

  1. Electrochemical Sensors
    Due to the active chemical properties, the testing gases generally have reducibility or oxidizability. Electrons are released or absorbed in the chemical reactions and a large number of electrons form a current. The current is proportional to the gas concentration, thus the gas concentration is obtained by measuring the current.
  2. Catalytic Combustion Sensors
    It works based on the principle that the heat is released from the combustion reaction of a surface combustible gas, namely combustion increases the temperature of the platinum wire coil and thus the resistance of the coil increases. The gas concentration is obtained by measuring the resistance value change of platinum wire. It’s suitable for measuring low concentration combustible gas.
  3. PID Photo Ion Sensors
    High energy ultraviolet rays ionize the organic gases, and then amplify the current of charged ions on the plate to measure. The current value reflects the gas concentration.
  4. Infrared Sensors
    Different combustible gas has different absorption ability to infrared ray. The concentration of combustible gas can be measured by detecting the current on the infrared photosensitive component.
  5. Semiconductor Sensor
    Due to the absorbability of semiconducting materials on gas, change the resistance value of the gas sensitive resistance to judge the existence of gas.
Product reviews
Works so good.
5
Marcel
Avatar
12/18/2018 6:56 PM
We bought this carbon monoxide detector as we have to monitor the CO exposure in the well. The detector arrived in time and was easy to install. So far, the detector gave us twice alarming. Works so good.
Was this review helpful? Yes No (0/0)
CO gas detector resolution
5
Jerry
Avatar
3/30/2020 6:54 PM
I’m looking for a fixed CO gas detector for my basement. I need 0-500ppm measuring range and I want to know what the resolution of your detector is in this range.
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, my friend. The resolution of 0-500ppm is 0.1ppm.
Essential Safety Partner
5
Jocob
Avatar
8/30/2023 7:47 PM
The Fixed Carbon Monoxide (CO) Gas Detector has become my ultimate safety companion. With its precise detection range from 0 to 1000 ppm, I feel a sense of security like never before. This device's unwavering vigilance against the silent threat of CO ensures that my surroundings are continuously monitored.
Was this review helpful? Yes No (0/0)
Recommended Gas Detector
5
Ephraim
Avatar
8/21/2025 9:13 PM
We are looking for single- and multi-gas flowmeters with data loggers for analyzing carbon monoxide, carbon dioxide, hydrogen, methane, ethane, and higher concentrations. Please advise on the options. This will be used to analyze battery thermal runaway gases.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Please tell us whether you prefer a portable or fixed gas detector. If you want 24/7 monitoring, a fixed gas detector is required.
2. Please tell us the concentrations of the gases you are measuring: CO, CO2, H2, CH4, C2H4, and C2H2. In particular, CO and H2 can interfere with each other, so we need the concentrations of these gases to recommend a suitable model.
Only registered users can write reviews
Customers who bought this item also bought

Fixed Hydrogen (H2) Gas Detector, 0 to 1000/2000/5000 ppm

GD300-H2
$634.77
Affordable price hydrogen gas detector for sale. Optional measuring range 0-1000/2000/5000 ppm, max 10000 ppm, supports remote control with output signal 4-20mA and RS485, high accuracy 3% F.S. H2 gas leak detector for hydrogen concentration detecting with sound & light alarm, fixed design, compact structure.

Fixed Carbon Dioxide (CO2) Gas Detector, 0 to 9999 ppm

GD300-CO2
$757.85
Economical price fixed gas detector from ideal supplier, for carbon dioxide detection. Measuring range 0-1000/2000/5000/9999 ppm for selection, remote control output signal 4-20mA and RS485, monitor CO2 concentration and sound & light alarm, high accuracy 3% F.S, fast response within 10s, 24h work and real-time display.

Fixed Hydrocarbons (HC) Gas Detector, 0 to 100%LEL

GD300-HC
$416.59
Cost-effective fixed Hydrocarbons (HC) gas detector for sale, with sound & light alarm, advanced sensor, measuring range from 0 to 100% LEL. This Hydrocarbons vapor monitor is designed to continuously monitor and detect the presence of HC gases in various industrial settings, such as oil refineries, chemical plants, and offshore drilling platforms.