Portable Chlorine (Cl2) Gas Detector, 0 to 10/50/100 ppm

$846.15
Portable Chlorine (Cl2) gas detector with built-in micro pump has measuring ranges of 0 to 10ppm / 20ppm / 50ppm / 100ppm for your selection, and give alarms with sound, light and vibration. Chlorine gas monitor uses high precision sensor, easy operation, high reliability and low price.
SKU: GD200-Cl2
*
*
*
Free Shipping
Delivery date: 6-12 days

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof

Specification

ModelGD200-Cl2
Sampling MethodPump type, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasChlorine (Cl2)
Range (Optional)*0 to 5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm or  0 to 200ppm
Resolution0.001ppm (0-5ppm), 0.01ppm (0-10/20/50ppm) or 0.1ppm (0-100/200ppm)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)

• Body Material: Stainless steel
• Input Range of Pressure Gauge: 0-25MPa
• Output Range of Pressure Gauge: 0-0.6Mpa
• Gauge Class: 2.5
• Input Pressure: ≤15MPa
• Output Pressure: ≤0.45MPa
• Rated Flow: 0.6 m3/h
• Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube

Note 1:

  • If you require a Cl2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Portable Chlorine (Cl2) Gas Detector Details

Applications

Portable Cl2 gas detector, pumping type, is used to measures the Chlorine gas concentration in the areas like chemical, pharmaceutical, municipal, water treatment, telecommunications, archaeology, laboratories, cold storage, wine making and other places, so as to ensure the safety of humans and animals.
Chlorine Cl2 Gas Detector Applications

Tips: How to Select a Gas Detector?

1. Gas type and concentration

  • If the majority of gas components are methane and other less toxic alkanes, LEL detector is undoubtedly the most appropriate.
  • If there are toxic gases such as Chlorine (Cl2), it is prior to select a specific gas detector, to ensure the safety of workers.
  • If the gas majorities are the organic, toxic and harmful gases, such as aromatic hydrocarbons, halogenated hydrocarbons, ammonia (amines), ethers, alcohols, lipids, a photoionization detector shall be selected.

2. Applications

The selection of gas detector differs from the industrial environments.

  • Fixed gas detector
    Such a gas detector is mostly used in industrial devices and production processes. It can be installed on a specific detection point to detect specific gas leaks.
  • Portable gas detector
    As the portable gas detector is easy to operate and compact, it can be carried to different production sites. In open occasion like open workshops for security alarm, a wearable diffusion-type gas detector is recommended because it can display the concentration of toxic and harmful gases continuously, real-time and accurately on site. If it’s used in a confined space, such as the reaction tank, storage tank or container, sewer or other underground pipe line, underground installations, cargo hold and tunnel, a multi gas detector with a built-in sampling pump is recommended.

Basic Settings of Portable Gas Detector

This video will show you the basic settings of ATO portable gas detectors including high/low alarm setting, language setting and time setting.

Calibration of Portable Gas Detector

This video will show how to calibrate the ATO portable gas detectors.

Concentration Detection of Pesticides Gas

Methyl bromide is an organic compound with the chemical formula CH3Br, which is mainly used as a pesticide, fumigant, refrigerant and solvent, and can also be used in organic synthesis.This video will mainly use methyl bromide and CH3Br as examples to introduce the detection of their concentrations.

How to Detect Hydrogen Sulfide Concentration in the Toilet

Hydrogen sulfide is a flammable acidic gas that smells like rotten eggs at low concentrations and is very toxic. In actual operation, it is necessary to ensure that the detection equipment or method used can accurately measure the concentration of hydrogen sulfide, and pay attention to safety issues during operation to avoid hydrogen sulfide poisoning.

How much C2H4 (ethylene) do ripe bananas and apples produce?

We have various gas detectors such as: CO, O2, O3, H2, NH3, H2S, CH4, Cl2, CH2O, etc, from 0~10000ppm, Industrial or daily use.

How Does a Portable Detector Work?

This video explains how a portable detector works and uses it to measure the air around you.

Portable Single Gas Detector Parameter Settings

In this video, we show you the menu settings of the ATO portable detector. Five button operation makes it very simple to control and activate functions. This device provides two alarm types, high alarm point and low alarm point, which can be adjusted as needed. The speed of the pump is also allowed to be adjusted. Calibration options include zero calibration and span calibration, both of which should be performed by qualified professionals under strict operating conditions using necessary accessories and standard gases.

How to Calibrate a Portable Gas Detector?

This video shows how to calibrate a portable gas detector. The ATO portable gas detector is lithium battery powered, has data logging capabilities and is available with a calibration kit.

Gas Detector Detection Range Setting

This video demonstrates the detection range setting of a portable gas detector.

Product reviews
Cl2 detector works as expected.
5
Eckert
Avatar
4/22/2019 7:46 PM
Planned to buy a detector for monitoring the Cl2 leakage in the Chlorine gas tank room. This pumping suction type is recommended. We have used it for detection, very fast and accurate. Works as expected. Good value for the price.
Was this review helpful? Yes No (0/0)
Nice portable chlorine gas detector
5
Lily
Avatar
11/6/2019 6:08 PM
Purchased this chlorine gas detector because we have to monitor the chlorine gas at any time in our water plant. Long-time exposure to chlorine gas can endanger our worker’s health. This portable detector can go with our work, and give us sound and vibration alarm once the chlorine concentration exceeds the alarm point. It is a great guardian for us. Nice product.
Was this review helpful? Yes No (0/0)
I have a question about the operation of the portable chlorine detector.
5
Matt
Avatar
12/30/2019 6:22 PM
Can this device detect chlorine gas in the environment of a room?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course. The detection range of this detector is 10-15 meters.
Chlorine gas detector alarm
5
Matt
Avatar
1/8/2020 6:30 PM
If I enter a room where there is presence of 1 ppm chlorine gas, will the detector give me an alarm without connecting to any auxiliary device?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it will sound an alarm once the gas concentration value in the room exceeds the alarm point without need of any auxiliary device.
Portable Chlorine (Cl2) Gas Detector Data Downloading
5
Fernando
Avatar
6/15/2020 6:57 PM
With your Portable Chlorine (Cl2) Gas Detector, is it possible to download data via the USB port every 5 or 10 seconds? Or is the frequency lower? If there were a way to provide a download every 5-10 seconds, that would resolve our issue.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, with our portable detector, you can download data via the USB port every 5 or 10 seconds, and the frequency lower time is every 5 seconds.
Data will be downloaded and transferred as an Excel file, and then you can open the file on the PC to view detected values.
Target Point Calibration (TPC) for Portable Chlorine (Cl2) Gas Detector
5
Jeff
Avatar
9/2/2020 6:36 PM
How often are we supposed to perform the Target Point Calibration (TPC) for Portable Chlorine (Cl2) Gas Detector ?
Was this review helpful? Yes No (0/0)
ATO Responded
It is supposed to perform the TPC annually but if the frequency of use is high, we recommend to perform every six months.
Does your Chlorine (Cl2) Gas Detector have a pump...
5
Mark
Avatar
10/12/2020 12:20 AM
Does your Chlorine (Cl2) Gas Detector have a pump where we can connect a hose and drop into a tank?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our Portable Chlorine (Cl2) Gas Detector is equipped with a built-in pump, which can be connected to a hose and directly inserted into the gas tank for testing.
I have a question about the operation of the portable chlorine detector.
5
Julien
Avatar
12/1/2021 1:22 AM
Can this device detect chlorine gas in the environment of a room? For example, if I enter a room where there is presence of 1 ppm chlorine gas, the device will give me an alarm without connecting to any auxiliary device.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course. The detection range is 10-15 meters. And it sounds like an alarm, no need for an auxiliary device.
How often should we perform target point calibration?
5
Cotton
Avatar
12/28/2021 8:24 PM
How often are we supposed to perform the Target Point Calibration (TPC) for portable chlorine (Cl2) gas detector?
Was this review helpful? Yes No (0/0)
ATO Responded
It is supposed to perform the TPC annually, but if use frequency is high, we recommend performing every six months.
We provide a one-year warranty.
Two questions
5
Alian
Avatar
7/29/2022 3:32 PM
1. the unit you used for accuracy, please spell out the "F.S."
2. I have bought a ATO-SKY2000-Cl2, but without the capability of downloading data. Can this function be added?
Was this review helpful? Yes No (0/0)
ATO Responded
1. F.S. is an acronym for full scale.
2. You can add data download function, but you have to send it back to add hardware and flash the program. For related operations, please contact our after-sales service.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof

Specification

ModelGD200-Cl2
Sampling MethodPump type, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasChlorine (Cl2)
Range (Optional)*0 to 5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm or  0 to 200ppm
Resolution0.001ppm (0-5ppm), 0.01ppm (0-10/20/50ppm) or 0.1ppm (0-100/200ppm)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)

• Body Material: Stainless steel
• Input Range of Pressure Gauge: 0-25MPa
• Output Range of Pressure Gauge: 0-0.6Mpa
• Gauge Class: 2.5
• Input Pressure: ≤15MPa
• Output Pressure: ≤0.45MPa
• Rated Flow: 0.6 m3/h
• Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube

Note 1:

  • If you require a Cl2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Portable Chlorine (Cl2) Gas Detector Details

Applications

Portable Cl2 gas detector, pumping type, is used to measures the Chlorine gas concentration in the areas like chemical, pharmaceutical, municipal, water treatment, telecommunications, archaeology, laboratories, cold storage, wine making and other places, so as to ensure the safety of humans and animals.
Chlorine Cl2 Gas Detector Applications

Tips: How to Select a Gas Detector?

1. Gas type and concentration

  • If the majority of gas components are methane and other less toxic alkanes, LEL detector is undoubtedly the most appropriate.
  • If there are toxic gases such as Chlorine (Cl2), it is prior to select a specific gas detector, to ensure the safety of workers.
  • If the gas majorities are the organic, toxic and harmful gases, such as aromatic hydrocarbons, halogenated hydrocarbons, ammonia (amines), ethers, alcohols, lipids, a photoionization detector shall be selected.

2. Applications

The selection of gas detector differs from the industrial environments.

  • Fixed gas detector
    Such a gas detector is mostly used in industrial devices and production processes. It can be installed on a specific detection point to detect specific gas leaks.
  • Portable gas detector
    As the portable gas detector is easy to operate and compact, it can be carried to different production sites. In open occasion like open workshops for security alarm, a wearable diffusion-type gas detector is recommended because it can display the concentration of toxic and harmful gases continuously, real-time and accurately on site. If it’s used in a confined space, such as the reaction tank, storage tank or container, sewer or other underground pipe line, underground installations, cargo hold and tunnel, a multi gas detector with a built-in sampling pump is recommended.
Product reviews
Cl2 detector works as expected.
5
Eckert
Avatar
4/22/2019 7:46 PM
Planned to buy a detector for monitoring the Cl2 leakage in the Chlorine gas tank room. This pumping suction type is recommended. We have used it for detection, very fast and accurate. Works as expected. Good value for the price.
Was this review helpful? Yes No (0/0)
Nice portable chlorine gas detector
5
Lily
Avatar
11/6/2019 6:08 PM
Purchased this chlorine gas detector because we have to monitor the chlorine gas at any time in our water plant. Long-time exposure to chlorine gas can endanger our worker’s health. This portable detector can go with our work, and give us sound and vibration alarm once the chlorine concentration exceeds the alarm point. It is a great guardian for us. Nice product.
Was this review helpful? Yes No (0/0)
I have a question about the operation of the portable chlorine detector.
5
Matt
Avatar
12/30/2019 6:22 PM
Can this device detect chlorine gas in the environment of a room?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course. The detection range of this detector is 10-15 meters.
Chlorine gas detector alarm
5
Matt
Avatar
1/8/2020 6:30 PM
If I enter a room where there is presence of 1 ppm chlorine gas, will the detector give me an alarm without connecting to any auxiliary device?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it will sound an alarm once the gas concentration value in the room exceeds the alarm point without need of any auxiliary device.
Portable Chlorine (Cl2) Gas Detector Data Downloading
5
Fernando
Avatar
6/15/2020 6:57 PM
With your Portable Chlorine (Cl2) Gas Detector, is it possible to download data via the USB port every 5 or 10 seconds? Or is the frequency lower? If there were a way to provide a download every 5-10 seconds, that would resolve our issue.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, with our portable detector, you can download data via the USB port every 5 or 10 seconds, and the frequency lower time is every 5 seconds.
Data will be downloaded and transferred as an Excel file, and then you can open the file on the PC to view detected values.
Target Point Calibration (TPC) for Portable Chlorine (Cl2) Gas Detector
5
Jeff
Avatar
9/2/2020 6:36 PM
How often are we supposed to perform the Target Point Calibration (TPC) for Portable Chlorine (Cl2) Gas Detector ?
Was this review helpful? Yes No (0/0)
ATO Responded
It is supposed to perform the TPC annually but if the frequency of use is high, we recommend to perform every six months.
Does your Chlorine (Cl2) Gas Detector have a pump...
5
Mark
Avatar
10/12/2020 12:20 AM
Does your Chlorine (Cl2) Gas Detector have a pump where we can connect a hose and drop into a tank?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our Portable Chlorine (Cl2) Gas Detector is equipped with a built-in pump, which can be connected to a hose and directly inserted into the gas tank for testing.
I have a question about the operation of the portable chlorine detector.
5
Julien
Avatar
12/1/2021 1:22 AM
Can this device detect chlorine gas in the environment of a room? For example, if I enter a room where there is presence of 1 ppm chlorine gas, the device will give me an alarm without connecting to any auxiliary device.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course. The detection range is 10-15 meters. And it sounds like an alarm, no need for an auxiliary device.
How often should we perform target point calibration?
5
Cotton
Avatar
12/28/2021 8:24 PM
How often are we supposed to perform the Target Point Calibration (TPC) for portable chlorine (Cl2) gas detector?
Was this review helpful? Yes No (0/0)
ATO Responded
It is supposed to perform the TPC annually, but if use frequency is high, we recommend performing every six months.
We provide a one-year warranty.
Two questions
5
Alian
Avatar
7/29/2022 3:32 PM
1. the unit you used for accuracy, please spell out the "F.S."
2. I have bought a ATO-SKY2000-Cl2, but without the capability of downloading data. Can this function be added?
Was this review helpful? Yes No (0/0)
ATO Responded
1. F.S. is an acronym for full scale.
2. You can add data download function, but you have to send it back to add hardware and flash the program. For related operations, please contact our after-sales service.
Only registered users can write reviews
Customers who bought this item also bought

Handheld Carbon Monoxide (CO) Gas Detector, 0 to 500/1000/2000 ppm

GD200-CO
$398.76
Handheld carbon monoxide (CO) detector use high accuracy sensor, pump suction type, selectable measuring range of 0 to 500 ppm, 0 to 1000 ppm, 0 to 2000 ppm, gas leak alarm with audible, visual and vibrating, compact size and light weight, long working time, easy to carry and operation.

Portable Hydrogen (H2) Gas Detector, 0 to 500/1000/2000 ppm

GD200-H2
$784.62
Portable hydrogen (H2) gas detector draws the gas sample by a micro pump, with high accuracy and reliability, measurement ranging from 0 to 500ppm, 1000ppm, 2000ppm, 5000ppm for your choice. Real-time LCD display, audible, visual & vibrating alarm, durable and compact design, easy to carry and operate. High precision H2 detector with measuring range 0-10ppm (0.001ppm) is also available.

Portable Carbon Dioxide (CO2) Infrared Gas Detector, 0 to 2000/5000/10000 ppm

GD200-CO2
$969.23
Portable carbon dioxide (CO2) infrared detector adopts high accuracy sensor, measuring range available with 0-2000ppm, 0-5000ppm, 0-10000ppm, or 0-10%VOL, 0-20%VOL, 0 to 100% VOL, with LCD display, audible, visual & vibrating alarm, compact size, easy to carry and operate.