Portable Benzene (C6H6) Gas Detector, 0 to 500/2000/5000/10000 ppm

$1,589.52
Portable Benzene gas detector is a single gas monitor used in industrial safety, environmental monitoring, and emergency response to detect and measure C6H6 levels in the air. Compact handheld C6H6 detector has high-precision sensor and sound and light alarm and optional 0 to 1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm.
SKU: GD200-C6H6
*
*
*
Free Shipping
Delivery date: 6-12 days

Get a portable Benzene gas detector for monitoring C6H6 gas concentration, available with a high-precision sensor, clear LCD display, gas alarm, compact handheld design and 0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm measuring range.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

Specification

ModelGD200-C6H6
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleHigh Precision PID
GasBenzene (C6H6)
Range (Optional)*0 to 1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm
Resolution0.001ppm (0-1/5/10/20ppm), 0.01ppm (0-50ppm), 0.1ppm (0-100/200ppm), 1ppm (0-500/1000/2000/5000/10000ppm)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note 1:

  • If you require a C6H6 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Handheld Ammonia (NH3) Gas Detector Details

Applications

HF gas detector applications

Tips: What can a portable Benzene (C6H6) gas detector do?

Our portable benzene gas detector is a vital tool used to monitor the concentration of benzene gas in the surrounding environment. Benzene is a highly toxic and flammable chemical compound commonly found in industrial settings, laboratories, and places where fuels are stored or used.

These detectors work by utilizing sensors that can detect even trace amounts of benzene gas in the air. When benzene levels exceed safe thresholds, the detector alerts users through alarms, lights, or digital displays. This early warning system is crucial for ensuring the safety of workers and preventing health hazards associated with benzene exposure.

Portable benzene gas detectors offer several key functionalities:

  • Real-time Monitoring: They continuously monitor benzene levels, providing instant feedback on any fluctuations or increases in concentration.
  • Portability: Being compact and lightweight, these detectors can be easily carried around, making them ideal for fieldwork, emergency response situations, or routine inspections.
  • Accuracy: Advanced sensor technology ensures accurate detection of benzene, even at low concentrations, enabling prompt action to mitigate risks.
  • Data Logging: ATO portable gas detectors are equipped with data logging capabilities, allowing for the recording of benzene levels over time. This data can be analyzed later for trend analysis or compliance reporting.
  • Safety Compliance: Portable benzene gas detectors help organizations comply with safety regulations and standards regarding benzene exposure limits, contributing to a safer work environment.

Overall, portable benzene gas detectors play a crucial role in safeguarding the health and well-being of individuals working in industries where benzene is present, helping to prevent accidents, illnesses, and environmental contamination.

Basic Settings of Portable Gas Detector

This video will show you the basic settings of ATO portable gas detectors including high/low alarm setting, language setting and time setting.

Calibration of Portable Gas Detector

This video will show how to calibrate the ATO portable gas detectors.

Concentration Detection of Pesticides Gas

Methyl bromide is an organic compound with the chemical formula CH3Br, which is mainly used as a pesticide, fumigant, refrigerant and solvent, and can also be used in organic synthesis.This video will mainly use methyl bromide and CH3Br as examples to introduce the detection of their concentrations.

How to Detect Hydrogen Sulfide Concentration in the Toilet

Hydrogen sulfide is a flammable acidic gas that smells like rotten eggs at low concentrations and is very toxic. In actual operation, it is necessary to ensure that the detection equipment or method used can accurately measure the concentration of hydrogen sulfide, and pay attention to safety issues during operation to avoid hydrogen sulfide poisoning.

How much C2H4 (ethylene) do ripe bananas and apples produce?

We have various gas detectors such as: CO, O2, O3, H2, NH3, H2S, CH4, Cl2, CH2O, etc, from 0~10000ppm, Industrial or daily use.

How Does a Portable Detector Work?

This video explains how a portable detector works and uses it to measure the air around you.

Portable Single Gas Detector Parameter Settings

In this video, we show you the menu settings of the ATO portable detector. Five button operation makes it very simple to control and activate functions. This device provides two alarm types, high alarm point and low alarm point, which can be adjusted as needed. The speed of the pump is also allowed to be adjusted. Calibration options include zero calibration and span calibration, both of which should be performed by qualified professionals under strict operating conditions using necessary accessories and standard gases.

How to Calibrate a Portable Gas Detector?

This video shows how to calibrate a portable gas detector. The ATO portable gas detector is lithium battery powered, has data logging capabilities and is available with a calibration kit.

Gas Detector Detection Range Setting

This video demonstrates the detection range setting of a portable gas detector.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Get a portable Benzene gas detector for monitoring C6H6 gas concentration, available with a high-precision sensor, clear LCD display, gas alarm, compact handheld design and 0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm measuring range.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

Specification

ModelGD200-C6H6
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleHigh Precision PID
GasBenzene (C6H6)
Range (Optional)*0 to 1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm
Resolution0.001ppm (0-1/5/10/20ppm), 0.01ppm (0-50ppm), 0.1ppm (0-100/200ppm), 1ppm (0-500/1000/2000/5000/10000ppm)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note 1:

  • If you require a C6H6 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Handheld Ammonia (NH3) Gas Detector Details

Applications

HF gas detector applications

Tips: What can a portable Benzene (C6H6) gas detector do?

Our portable benzene gas detector is a vital tool used to monitor the concentration of benzene gas in the surrounding environment. Benzene is a highly toxic and flammable chemical compound commonly found in industrial settings, laboratories, and places where fuels are stored or used.

These detectors work by utilizing sensors that can detect even trace amounts of benzene gas in the air. When benzene levels exceed safe thresholds, the detector alerts users through alarms, lights, or digital displays. This early warning system is crucial for ensuring the safety of workers and preventing health hazards associated with benzene exposure.

Portable benzene gas detectors offer several key functionalities:

  • Real-time Monitoring: They continuously monitor benzene levels, providing instant feedback on any fluctuations or increases in concentration.
  • Portability: Being compact and lightweight, these detectors can be easily carried around, making them ideal for fieldwork, emergency response situations, or routine inspections.
  • Accuracy: Advanced sensor technology ensures accurate detection of benzene, even at low concentrations, enabling prompt action to mitigate risks.
  • Data Logging: ATO portable gas detectors are equipped with data logging capabilities, allowing for the recording of benzene levels over time. This data can be analyzed later for trend analysis or compliance reporting.
  • Safety Compliance: Portable benzene gas detectors help organizations comply with safety regulations and standards regarding benzene exposure limits, contributing to a safer work environment.

Overall, portable benzene gas detectors play a crucial role in safeguarding the health and well-being of individuals working in industries where benzene is present, helping to prevent accidents, illnesses, and environmental contamination.

Only registered users can write reviews
Customers who bought this item also bought

Fixed Phosphine (PH3) Gas Detector, 0 to 100/1000/3000 ppm

GD300-PH3
$779.89
Selling a PH3 phosphine gas detector with an alarm light at a low price. This is a wall-mounted explosion-proof gas detector with a measuring range of 0 to 100/1000/3000 ppm. It can work continuously for 24 hours and is powered by 12-24V DC, the gas detector has a connection distance of 1000m, and the protection level is IP65.

Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 to 100/500/1000 ppm

GD300-NO2
$734.87
Fixed nitrogen dioxide (NO2) gas detectors for detecting NO2 concentrations for sale, with optional measuring ranges from 0 to 100/500/1000 ppm. The NO2 leak detector has audible and visual gas alarm and data display functions, a unique infrared control function, which can control the equipment non-contactly, the signal output is optional 4-20mA and RS485, and the explosion-proof design is fast, reliable, and stable.

Fixed Benzene (C6H6) Gas Detector, 0 to 10/100/200/1000/10000 ppm

GD300-C6H6
$1,765.79
Buy favorable price fixed Benzene (C6H6) gas detector online, with advanced sensor, measuring ranges of 0-1/10/50/100/200/1000/2000/5000/10000ppm. This C6H6 gas monitor with sound & light alarm is a safey device that monitor and alert individuals to the presence of Benzene gas in industrial, laboratory, or commercial settings.