5 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output

$392.35
5 hp variable frequency drive, single phase 110v-120v input, single phase and three phase 220v-240v output, V/F & vector control, running AC motor on single phase 120v power supply via ATO VFD.
SKU: GK3000-SP1S1-004
Free Shipping
Delivery date: 6-12 days

5 hp (4 kW) VFD, 1 phase for single phase AC motor, single phase to 3 phase converter. 110v/115v/120v input, 220v/230v/240v output.

Specification:

BasicsModelEM15-SP1S1-004
Capacity5 hp (4 kW)
Shipping weight5 kg
Dimension (W x H x D)162*250*191 mm
I/O FeatureRated current16 A
Input voltage1 phase 120V AC ±15%
Input frequency50Hz/60Hz
Output voltage1 phase or 3 phase 220V AC ±15%
Output frequency0~320Hz (SFC)
Control FeatureControl modeV/F control; vector control
CommunicationOffer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humiditysmaller than 95%RH, non-condensation
Altitude≤1000m; VFD will be derated if above 1000m
VibrationLess than 5.9 m/s2 (0.6 g)
Coolingforced air cooling
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

5hp VFD Single Phase 120V Input Details

Tips: How to build a trouble-free VFD system

  1. Spent a lot of time up front to size the VFD properly for the application.
  2. Spent time up front to research the VFD product specified to be used for the application - in some cases I have had to recommend to the end user an alternative VFD model as a better fit for the application.
  3. Designed the power circuits with the VFD, the power supply, the cable run and the location of the motor in mind. Use input reactors and harmonic filters or chokes on the output as specified by the VFD manufacturer. Use VFD rated cables when necessary, and checked that the motor load was rated as inverter duty.
  4. Designed the VFD panel so that there was adequate ventilation/cooling for the VFD. Provided proper grounding points for the VFD, power supply, and connection points for the shields if shielded VFD cables used.
  5. Inspected the panel construction carefully, to ensure that the VFD and associated equipment were properly installed in the panel and that no metal shavings or chips entered this equipment.
  6. Repeat 5 when the equipment is installed at site, and check installation to ensure that it meets the recommendations of the manufacturer.

Running a Three-phase Motor on a Single-phase Supply with a Frequency Converter

How to run a three phase or single phase motor with ATO VFD on 120V power supply. Take a 2 hp, single phase 120V input, single phase or three phase 220V output variable frequency drive as an example. It shows you how to wire, set parameters, commissioning VFD, run motors, etc.

VFD Programming for Stable Water Pressure in Water Supply System

A three-phase motor can be regulated using a single-phase 120V to three-phase 220V VFD, and control can be managed through terminals, as demonstrated in the following video.

Variable Frequency Drive Setting

In the video, it's demonstrated that ATO VFD offers multiple methods to adjust the frequency: Not only can you use the knob on the panel, but you can also utilize the buttons for adjustments.

Basic Troubleshooting Guide for VFD

In this video, ATO will show you the vfd basic troubleshooting guide.

How Many VFD Control Methods Do You Know?

Several methods to control the frequency of VFD:

1. Switch Button control: Use the switch signal to directly control the start and stop of the VFD (the VFD start frequency is fixed), and the multi-speed control method can be used to activate the speed of each section of the VFD.

2. Analog control: Use 5V or 0~20mA to control the frequency of the VFD, and at the same time can control the start and stop of the VFD in cooperation with the switch.

3. VFD potentiometer control: The VFD has its own potentiometer input terminal, and the VFD is directly controlled by the potentiometer.

4. Modbus-RTU control: Use RS485 interface to transmit data with Modbus-RTU protocol, which can monitor VFD, modify frequency, start and stop, etc.

5. DTU wireless remote control:Combine DTU terminal and VFD for wireless transmission. (DTU output analog quantity to control VFD frequency)

Running a Single or Three Phase Motor with a VFD on 120V Power

In this video, ATO will show you how to run a 120v variable frequency drive motor.

Running a Split-phase Motor with a 120V VFD (Terminal Control)

The ATO 120V inverter in the video can run single-phase motors/split-phase motors, three-phase motors. You can run the VFD in many ways.

Product reviews
ATO 120V VFD
5
Adrian
Avatar
10/26/2018 12:05 AM
This 5 hp VFD is a good product, 120v single phase input, 240v 3 phase output, fully comply with my request. Moreover, its video is very useful.
Was this review helpful? Yes No (0/0)
Can I use a VFD to control the speed?
5
Harolde
Avatar
9/28/2021 8:30 PM
What is the motor type of your vacuum pump? Can I use VFD with it to control the speed?
Was this review helpful? Yes No (0/0)
ATO Responded
It is a 1-phase induction motor, and yes, you can use VFD to control the speed. But note that the single phase motor should not be adjusted to run based on a lower frequency than 80% of its rated frequency for a long time, otherwise the motor may fail.
5hp VFD Modbus and PLC connection method
5
Fayec
Avatar
11/26/2021 12:07 AM
For your GK3000-SP1S1-004, is Modbus the only way to interface with the PLC or is there any other way to do that? Using Ethernet IP or a 4-20mA output?
Was this review helpful? Yes No (0/0)
ATO Responded
You can use 4-20mA signal to interface with PLC, but no Ethernet IP.
How can I do factory reset? How to set up and control the speed with 3 different frequencies with 3 different inputs?
5
Chandler
Avatar
9/9/2022 3:21 AM
1. How do I reset my factory settings? Is it P3.01 - 1?

2. how to configure and regulate the speed using three separate inputs and three different frequencies, 35 Hz, 50 Hz, and 60 Hz.
The amount is P0.23, P0.25, P0.27, P0.01 - 8, or P4.00 -.
Was this review helpful? Yes No (0/0)
ATO Responded
1. To return to the factory settings, set P3.01=10.
2. To regulate the speed with three different frequencies, set the following parameters:
P4.00=1
P4.01=2
P4.02=3
P3.26=35
P3.27=50
P3.29=60
120v Victron 3000w Inverter on Boat
5
Blair
Avatar
10/1/2022 12:24 AM
can I use the 120v output plug on my boat to use a 230v Single Phase Air Compressor?  Or would everything just be much easier to get a new compressor engine that will work with the 120v boat setup?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can use the 120V output plug to drive your 230V single phase air compressor.
Could you confirm the VFD wiring?
5
blanche
Avatar
6/12/2023 7:00 PM
Hope you are doing well.
We ordered 5 of these units and now are at a point to install them and power up our equipment. Can you confirm the wiring please?
We purchased these VFD’s (SKU: GK3000-SP1S1-004) from ATO because we have equipment that runs on 220-230v, 50Hz (European). Our incoming power in Canada is 110v, 60 Hz, Single phase. Can you please confirm the proper wiring where we connect the incoming power of 110v, 60 Hz and then the outgoing power to the equipment as in attached picture our temp wiring so we can confirm its correct.
Also, we are wondering if you can confirm how this VFD works. When we turn it on, it ramps up from 0 to 50Hz. It takes a bit of time. Is there a way that it can be set to ramp from 0-50 in under 3 seconds? Also, if the power is disconnected, is there an auto start button so that when the power comes back on, it powers back up?
Is there a rep in Calgary area who has experience setting these VFD’s up or a training video on how they work and are properly set up?
Was this review helpful? Yes No (0/0)
ATO Responded
1. We confirm that your VFD wiring is correct. And this VFD’s (SKU: GK3000-SP1S1-004) supports 110v, 60 Hz, Single phase.
2. The VFD output terminal can only be directly connected to the motor, and cannot be used as a power supply to connect to equipment. So the equipment you mentioned is the motor?
3. Please refer to the attached parameter setting documentation. Regarding the automatic restart operation function, can you please tell us whether the VFD is started directly through the panel or operated by the terminal?
4. For setting these VFD’s up, please refer to the link: https://www.youtube.com/watch?v=N8wYR6NmX1I&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=16
What the power consumption of the actual VFD is?
5
Alob
Avatar
8/4/2023 12:15 AM
I was just hoping that you might be able to confirm what the power consumption of the actual VFD unit is? We know that the model we purchased has a capacity of 5 hp (4 kW), but do you have a figure on how much power the VFD itself draws? If we are running a pump which runs at 1 kW, we are hoping to understand what the total consumption of that system would be with this unit.
Was this review helpful? Yes No (0/0)
ATO Responded
The unit you purchased has a rated power of 4kW and a rated output current of 16A. When the VFD is running at full load, the current at the input terminal is about 4 times the rated current, which is 60A. Of course, the current capacity of the input terminal is related to the actual load capacity. If the pump you are running is 1KW and the rated current is about 5A, then the current at the input terminal is about 20A. You can run the motor with No load and use a clamp ammeter to test the actual current.
Can you quote a DC choke for this drive?
5
Kim
Avatar
2/5/2024 8:07 PM
I am quoting a 120V (generator power) input application. Can you quote a DC choke for this drive? Trying to reduce potential harmonics...thank you
Was this review helpful? Yes No (0/0)
ATO Responded
Our low-power VFD has No internal reactor. Reactors and filters can be added externally to reduce harmonics.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

5 hp (4 kW) VFD, 1 phase for single phase AC motor, single phase to 3 phase converter. 110v/115v/120v input, 220v/230v/240v output.

Specification:

BasicsModelEM15-SP1S1-004
Capacity5 hp (4 kW)
Shipping weight5 kg
Dimension (W x H x D)162*250*191 mm
I/O FeatureRated current16 A
Input voltage1 phase 120V AC ±15%
Input frequency50Hz/60Hz
Output voltage1 phase or 3 phase 220V AC ±15%
Output frequency0~320Hz (SFC)
Control FeatureControl modeV/F control; vector control
CommunicationOffer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humiditysmaller than 95%RH, non-condensation
Altitude≤1000m; VFD will be derated if above 1000m
VibrationLess than 5.9 m/s2 (0.6 g)
Coolingforced air cooling
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

5hp VFD Single Phase 120V Input Details

Tips: How to build a trouble-free VFD system

  1. Spent a lot of time up front to size the VFD properly for the application.
  2. Spent time up front to research the VFD product specified to be used for the application - in some cases I have had to recommend to the end user an alternative VFD model as a better fit for the application.
  3. Designed the power circuits with the VFD, the power supply, the cable run and the location of the motor in mind. Use input reactors and harmonic filters or chokes on the output as specified by the VFD manufacturer. Use VFD rated cables when necessary, and checked that the motor load was rated as inverter duty.
  4. Designed the VFD panel so that there was adequate ventilation/cooling for the VFD. Provided proper grounding points for the VFD, power supply, and connection points for the shields if shielded VFD cables used.
  5. Inspected the panel construction carefully, to ensure that the VFD and associated equipment were properly installed in the panel and that no metal shavings or chips entered this equipment.
  6. Repeat 5 when the equipment is installed at site, and check installation to ensure that it meets the recommendations of the manufacturer.

Product reviews
ATO 120V VFD
5
Adrian
Avatar
10/26/2018 12:05 AM
This 5 hp VFD is a good product, 120v single phase input, 240v 3 phase output, fully comply with my request. Moreover, its video is very useful.
Was this review helpful? Yes No (0/0)
Can I use a VFD to control the speed?
5
Harolde
Avatar
9/28/2021 8:30 PM
What is the motor type of your vacuum pump? Can I use VFD with it to control the speed?
Was this review helpful? Yes No (0/0)
ATO Responded
It is a 1-phase induction motor, and yes, you can use VFD to control the speed. But note that the single phase motor should not be adjusted to run based on a lower frequency than 80% of its rated frequency for a long time, otherwise the motor may fail.
5hp VFD Modbus and PLC connection method
5
Fayec
Avatar
11/26/2021 12:07 AM
For your GK3000-SP1S1-004, is Modbus the only way to interface with the PLC or is there any other way to do that? Using Ethernet IP or a 4-20mA output?
Was this review helpful? Yes No (0/0)
ATO Responded
You can use 4-20mA signal to interface with PLC, but no Ethernet IP.
How can I do factory reset? How to set up and control the speed with 3 different frequencies with 3 different inputs?
5
Chandler
Avatar
9/9/2022 3:21 AM
1. How do I reset my factory settings? Is it P3.01 - 1?

2. how to configure and regulate the speed using three separate inputs and three different frequencies, 35 Hz, 50 Hz, and 60 Hz.
The amount is P0.23, P0.25, P0.27, P0.01 - 8, or P4.00 -.
Was this review helpful? Yes No (0/0)
ATO Responded
1. To return to the factory settings, set P3.01=10.
2. To regulate the speed with three different frequencies, set the following parameters:
P4.00=1
P4.01=2
P4.02=3
P3.26=35
P3.27=50
P3.29=60
120v Victron 3000w Inverter on Boat
5
Blair
Avatar
10/1/2022 12:24 AM
can I use the 120v output plug on my boat to use a 230v Single Phase Air Compressor?  Or would everything just be much easier to get a new compressor engine that will work with the 120v boat setup?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can use the 120V output plug to drive your 230V single phase air compressor.
Could you confirm the VFD wiring?
5
blanche
Avatar
6/12/2023 7:00 PM
Hope you are doing well.
We ordered 5 of these units and now are at a point to install them and power up our equipment. Can you confirm the wiring please?
We purchased these VFD’s (SKU: GK3000-SP1S1-004) from ATO because we have equipment that runs on 220-230v, 50Hz (European). Our incoming power in Canada is 110v, 60 Hz, Single phase. Can you please confirm the proper wiring where we connect the incoming power of 110v, 60 Hz and then the outgoing power to the equipment as in attached picture our temp wiring so we can confirm its correct.
Also, we are wondering if you can confirm how this VFD works. When we turn it on, it ramps up from 0 to 50Hz. It takes a bit of time. Is there a way that it can be set to ramp from 0-50 in under 3 seconds? Also, if the power is disconnected, is there an auto start button so that when the power comes back on, it powers back up?
Is there a rep in Calgary area who has experience setting these VFD’s up or a training video on how they work and are properly set up?
Was this review helpful? Yes No (0/0)
ATO Responded
1. We confirm that your VFD wiring is correct. And this VFD’s (SKU: GK3000-SP1S1-004) supports 110v, 60 Hz, Single phase.
2. The VFD output terminal can only be directly connected to the motor, and cannot be used as a power supply to connect to equipment. So the equipment you mentioned is the motor?
3. Please refer to the attached parameter setting documentation. Regarding the automatic restart operation function, can you please tell us whether the VFD is started directly through the panel or operated by the terminal?
4. For setting these VFD’s up, please refer to the link: https://www.youtube.com/watch?v=N8wYR6NmX1I&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=16
What the power consumption of the actual VFD is?
5
Alob
Avatar
8/4/2023 12:15 AM
I was just hoping that you might be able to confirm what the power consumption of the actual VFD unit is? We know that the model we purchased has a capacity of 5 hp (4 kW), but do you have a figure on how much power the VFD itself draws? If we are running a pump which runs at 1 kW, we are hoping to understand what the total consumption of that system would be with this unit.
Was this review helpful? Yes No (0/0)
ATO Responded
The unit you purchased has a rated power of 4kW and a rated output current of 16A. When the VFD is running at full load, the current at the input terminal is about 4 times the rated current, which is 60A. Of course, the current capacity of the input terminal is related to the actual load capacity. If the pump you are running is 1KW and the rated current is about 5A, then the current at the input terminal is about 20A. You can run the motor with No load and use a clamp ammeter to test the actual current.
Can you quote a DC choke for this drive?
5
Kim
Avatar
2/5/2024 8:07 PM
I am quoting a 120V (generator power) input application. Can you quote a DC choke for this drive? Trying to reduce potential harmonics...thank you
Was this review helpful? Yes No (0/0)
ATO Responded
Our low-power VFD has No internal reactor. Reactors and filters can be added externally to reduce harmonics.
Only registered users can write reviews
Customers who bought this item also bought

3 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0022
$238.14
Low price 3hp VFD, convert 220V/230V/240V 1 phase to 3 phase, 9.6 amps, RS485 enabled, shipping weight 3kg, manufacturer direct sale.

1/2 hp (0.4 kW) VFD, Single Phase Input & Output

GK3000-1S0004
$162.46
Inexpensive 1/2 hp VFD, 1 phase for single phase AC motor speed controls, 220V - 240V 4 amps, manufacturer direct sale.

3 hp (2.2kW) 3 phase 6 pole AC Induction Motor

ATO-IM-22006P
$675.06
Three phase induction motor or asynchronous motor, with output 3 hp/2.2kW, working voltage 380V 50Hz, rated speed 6P 940rpm, nominal torque 22.35Nm. Cheap 3 phase induction motor features optimum structure, high reliability, low noise, easy to install and simple to operate.