2 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output

$315.38
Affordable 2 hp variable frequency drive, single phase 110v-120v input, single phase and three phase 220v-240v output, designed for driving single/three phase AC motor via 120v power supply.
SKU: GK3000-SP1S1-1d5
Free Shipping
Delivery date: 2-3 days

2 hp (1.5 kW) VFD, single phase 110v/120v input to single phase 220v, 230v, 240v output, single phase to three phase, 7 amps.

Specification:

BasicsModelEM15-SP1S1-1d5
Capacity2 hp (1.5 kW)
Shipping weight3 kg
Dimension (W x H x D)120*205*166 mm
I/O FeatureRated current7 A
Input voltage1 phase 120V AC ±15% (Set FE-00=0)
Input frequency50Hz/60Hz
Output voltage1 phase or 3 phase 220V AC ±15%
Output frequency0~320Hz (SFC)
Control FeatureControl modeV/F control; vector control
CommunicationOffer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humiditysmaller than 95%RH, non-condensation
Altitude≤1000m; VFD will be derated if above 1000m
VibrationLess than 5.9 m/s2 (0.6 g)
Coolingforced air cooling
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

2hp VFD Single Phase 120v Input Details

Tips: Variable Frequency Drive vs Soft Starter

If you need to vary the speed of the driven load, then a VFD is definitely the choice. If you are looking to reduce the starting current and the starting torque of an induction motor, then a soft starter can be selected.
If energy savings (reduced speed) is the issue a VFD will almost always be the first choice, but again the driven load, (VT) and application require review and sizing considerations. If speed control is the consideration then a constant torque load will require a VFD. The motor basics we have had to live with, NEMA design A, B, C & D are there for a reason as one design doesn't fit all applications. The controller is just another tool to use within it's limitations to provide the desired result for an application.
Soft starter - considerably cheaper than VFDs, much more efficient, does not require harmonic mitigation, but draws 3 - 4 times start current and does not offer variable speed feature. Understanding the application and exactly what you are trying to achieve would be the most important factor.

Running a Three-phase Motor on a Single-phase Supply with a Frequency Converter

How to run a three phase or single phase motor with ATO VFD on 120V power supply. Take a 2 hp, single phase 120V input, single phase or three phase 220V output variable frequency drive as an example. It shows you how to wire, set parameters, commissioning VFD, run motors, etc.

VFD Programming for Stable Water Pressure in Water Supply System

A three-phase motor can be regulated using a single-phase 120V to three-phase 220V VFD, and control can be managed through terminals, as demonstrated in the following video.

Variable Frequency Drive Setting

In the video, it's demonstrated that ATO VFD offers multiple methods to adjust the frequency: Not only can you use the knob on the panel, but you can also utilize the buttons for adjustments.

Basic Troubleshooting Guide for VFD

In this video, ATO will show you the vfd basic troubleshooting guide.

How Many VFD Control Methods Do You Know?

Several methods to control the frequency of VFD:

1. Switch Button control: Use the switch signal to directly control the start and stop of the VFD (the VFD start frequency is fixed), and the multi-speed control method can be used to activate the speed of each section of the VFD.

2. Analog control: Use 5V or 0~20mA to control the frequency of the VFD, and at the same time can control the start and stop of the VFD in cooperation with the switch.

3. VFD potentiometer control: The VFD has its own potentiometer input terminal, and the VFD is directly controlled by the potentiometer.

4. Modbus-RTU control: Use RS485 interface to transmit data with Modbus-RTU protocol, which can monitor VFD, modify frequency, start and stop, etc.

5. DTU wireless remote control:Combine DTU terminal and VFD for wireless transmission. (DTU output analog quantity to control VFD frequency)

Running a Single or Three Phase Motor with a VFD on 120V Power

In this video, ATO will show you how to run a 120v variable frequency drive motor.

Running a Split-phase Motor with a 120V VFD (Terminal Control)

The ATO 120V inverter in the video can run single-phase motors/split-phase motors, three-phase motors. You can run the VFD in many ways.

Product reviews
Does your VFD have soft start capability
5
Jeffrey
Avatar
8/10/2020 7:22 PM
I want to check if the GK3000-SP1S1-1d5 frequency drive has soft start capability.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can, in adtion to speed control and much more features.
I am very satisfied with this 2 hp VFD
5
Thoms
Avatar
6/7/2021 12:58 AM
I am looking to select a VFD appropriate for a pump motor. I was looking at SKU GK3000-SP1S1-1d5 to go along with a pump motor we may purchase: 1/3 HP, single phase, FLA 7/4 @ 115/230V. Can you please confirm if this is a good option?
Was this review helpful? Yes No (0/0)
ATO Responded
As long as your motor will be configured for 1-phase, 230V and your supply voltage (VFD input) is 110/120V, then VFD of GK3000-SP1S1-1d5 will be the appropriate drive for your pump motor.
Braking resistor for 2 hp VFD
5
Kunde
Avatar
10/18/2021 8:18 PM
What is the recommended braking resistor value of 2 hp VFD, single phase 120V input, 1ph/3ph 220V output?
Was this review helpful? Yes No (0/0)
ATO Responded
Braking resistor: 100W, ≥70Ω. And the resistor should be connected between PB and P+ terminals.
I bought this frequency inverter
5
June
Avatar
5/29/2022 11:49 PM
I bought the EM15-SP1S1-1D5 Frequency inverter and want to make sure I wire it correctly. I need to know which are load and ground. I also to make sure of the input power connections. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
The input power is connected to L N, the motor is connected to U V, and the ground wires of the power supply and the motor are connected to the E terminal.
Is that the actual output voltage and amps?
5
Ahmed
Avatar
3/3/2023 2:10 AM
During run mode, the shift key changes the display from Hz to V and A. Is that the actual output voltage and amps?
If so, the voltage exceeds 300v even though the motor specs (F1-01 through F1-05) have been saved during setup/configuration.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Yes, during the run mode, the shift key changes the display from Hz to V and A.
2. The displayed voltage you mentioned exceeds 300v, this is the DC bus voltage, not the input/output AC voltage. The VFD does not display the output voltage because the output voltage generally changes.
Is it capable of communicating via Bacnet?
5
Phill
Avatar
10/17/2023 1:20 AM
We ordered the drive in the subject line.  Is it capable of communicating via Bacnet?
Was this review helpful? Yes No (0/0)
ATO Responded
Our VFD currently only supports RS485 communication function and does Not have Bacnet.
Will GK3000-SP1S1-1d5 drive accept 100V input?
5
Bruce
Avatar
10/24/2023 2:09 AM
Will GK3000-SP1S1-1d5 drive accept 100V input? And if yes, then what will be its 3-phase output voltage in that case?
Was this review helpful? Yes No (0/0)
ATO Responded
The GK3000-SP1S1-1d5 drive can accept 100V input, and its 3-phase output voltage will be three phase 190V.
In this case, your motor load is required to be very light (less than 70% of the VFD rated current is used after operation).
The 100 Ω power supply at the input end must be stable before it can be used normally.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

2 hp (1.5 kW) VFD, single phase 110v/120v input to single phase 220v, 230v, 240v output, single phase to three phase, 7 amps.

Specification:

BasicsModelEM15-SP1S1-1d5
Capacity2 hp (1.5 kW)
Shipping weight3 kg
Dimension (W x H x D)120*205*166 mm
I/O FeatureRated current7 A
Input voltage1 phase 120V AC ±15% (Set FE-00=0)
Input frequency50Hz/60Hz
Output voltage1 phase or 3 phase 220V AC ±15%
Output frequency0~320Hz (SFC)
Control FeatureControl modeV/F control; vector control
CommunicationOffer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humiditysmaller than 95%RH, non-condensation
Altitude≤1000m; VFD will be derated if above 1000m
VibrationLess than 5.9 m/s2 (0.6 g)
Coolingforced air cooling
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

2hp VFD Single Phase 120v Input Details

Tips: Variable Frequency Drive vs Soft Starter

If you need to vary the speed of the driven load, then a VFD is definitely the choice. If you are looking to reduce the starting current and the starting torque of an induction motor, then a soft starter can be selected.
If energy savings (reduced speed) is the issue a VFD will almost always be the first choice, but again the driven load, (VT) and application require review and sizing considerations. If speed control is the consideration then a constant torque load will require a VFD. The motor basics we have had to live with, NEMA design A, B, C & D are there for a reason as one design doesn't fit all applications. The controller is just another tool to use within it's limitations to provide the desired result for an application.
Soft starter - considerably cheaper than VFDs, much more efficient, does not require harmonic mitigation, but draws 3 - 4 times start current and does not offer variable speed feature. Understanding the application and exactly what you are trying to achieve would be the most important factor.

Product reviews
Does your VFD have soft start capability
5
Jeffrey
Avatar
8/10/2020 7:22 PM
I want to check if the GK3000-SP1S1-1d5 frequency drive has soft start capability.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can, in adtion to speed control and much more features.
I am very satisfied with this 2 hp VFD
5
Thoms
Avatar
6/7/2021 12:58 AM
I am looking to select a VFD appropriate for a pump motor. I was looking at SKU GK3000-SP1S1-1d5 to go along with a pump motor we may purchase: 1/3 HP, single phase, FLA 7/4 @ 115/230V. Can you please confirm if this is a good option?
Was this review helpful? Yes No (0/0)
ATO Responded
As long as your motor will be configured for 1-phase, 230V and your supply voltage (VFD input) is 110/120V, then VFD of GK3000-SP1S1-1d5 will be the appropriate drive for your pump motor.
Braking resistor for 2 hp VFD
5
Kunde
Avatar
10/18/2021 8:18 PM
What is the recommended braking resistor value of 2 hp VFD, single phase 120V input, 1ph/3ph 220V output?
Was this review helpful? Yes No (0/0)
ATO Responded
Braking resistor: 100W, ≥70Ω. And the resistor should be connected between PB and P+ terminals.
I bought this frequency inverter
5
June
Avatar
5/29/2022 11:49 PM
I bought the EM15-SP1S1-1D5 Frequency inverter and want to make sure I wire it correctly. I need to know which are load and ground. I also to make sure of the input power connections. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
The input power is connected to L N, the motor is connected to U V, and the ground wires of the power supply and the motor are connected to the E terminal.
Is that the actual output voltage and amps?
5
Ahmed
Avatar
3/3/2023 2:10 AM
During run mode, the shift key changes the display from Hz to V and A. Is that the actual output voltage and amps?
If so, the voltage exceeds 300v even though the motor specs (F1-01 through F1-05) have been saved during setup/configuration.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Yes, during the run mode, the shift key changes the display from Hz to V and A.
2. The displayed voltage you mentioned exceeds 300v, this is the DC bus voltage, not the input/output AC voltage. The VFD does not display the output voltage because the output voltage generally changes.
Is it capable of communicating via Bacnet?
5
Phill
Avatar
10/17/2023 1:20 AM
We ordered the drive in the subject line.  Is it capable of communicating via Bacnet?
Was this review helpful? Yes No (0/0)
ATO Responded
Our VFD currently only supports RS485 communication function and does Not have Bacnet.
Will GK3000-SP1S1-1d5 drive accept 100V input?
5
Bruce
Avatar
10/24/2023 2:09 AM
Will GK3000-SP1S1-1d5 drive accept 100V input? And if yes, then what will be its 3-phase output voltage in that case?
Was this review helpful? Yes No (0/0)
ATO Responded
The GK3000-SP1S1-1d5 drive can accept 100V input, and its 3-phase output voltage will be three phase 190V.
In this case, your motor load is required to be very light (less than 70% of the VFD rated current is used after operation).
The 100 Ω power supply at the input end must be stable before it can be used normally.
Only registered users can write reviews
Customers who bought this item also bought

3 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output

GK3000-SP1S1-2d2
$346.10
3 hp single phase 120v input, single phase and three phase 220v output variable frequency drive, specially designed for 120v power supply, manufacturer direct sale.

Rotary Torque Sensor, Non-Contact, Shaft to Shaft, 0.05-300000 Nm

ATO-TQS-D01
$1,015.34
Rotary torque sensor is a non-contact torque sensor with two shafts and shaft keys, a male plug and a mounting base. Shaft torque sensors have a capacity range from 10 Nm/50 Nm/2000 Nm/10000 Nm to 300000 Nm. It can be applied to torque/rotary speed/power measurement of AC/DC motor, gear motor and diesel generator for a long-term.