1/2 hp (0.4 kW) VFD, Single Phase Input & Output

$162.46
Inexpensive 1/2 hp VFD, 1 phase for single phase AC motor speed controls, 220V - 240V 4 amps, manufacturer direct sale.
SKU: GK3000-1S0004
Availability: In stock
Free Shipping
Delivery date: 2-3 days

1/2 hp variable frequency drive, 0.4 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0004
Capacity1/2 hp (0.4 kW)
Shipping weight2 kg
Dimension142*85*110 mm
I/O FeatureRated current4 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequency0~1000Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Start frequency0.40Hz~20.00Hz
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuating
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
  4. If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.

Details

400W Single Phase VFD Details
Tips: 7 points about variable frequency drive application environment
The variable frequency drive may not be normally operated in any cases, so the user is necessary to have more understanding about load, environmental requirements and the VFD itself. There are seven points should be pay attention to:

  1. Because the motor temperature will be high under long-term and low-speed operation, the fan cooling capacity will also reduce, so it must use high reduction ratio VFD or 6 grade motor to let the motor running in higher frequency.
  2. The variable frequency drive installation site must require the standard environment, or it will easily cause failure or shorten the service life. The distance between VFD and driving motor should not be more than 50 meters, for longer distances need to reduce the carrier frequency or increase output reactor option to function properly.
  3. Type of load and VFD selection: Different load of motor has different requirements of VFD.
  4. Fan and pump is the most common load: They have the simplest requirements of the variable frequency drive, as long as the variable frequency drive capacity is equal to the motor capacity (air compressor, deep water pump, sediment pump, and fast changing music fountain need higher capacity).
  5. Crane load: This type of load is characterized by a great impact on the starting, so it requires a margin of the VFD. At the same time, there will be energy feedback when putting down the weight, so it requires brake unit or share bus.
  6. Uneven load: Some load maybe sometimes light and sometimes heavy, this time should be in accordance with the heavy load situation to select the variable frequency drive capacity, such as rolling machinery, crushing machinery, mixer, etc.
  7. High inertia load: Such as centrifuges, punching presses, cement rotary kiln, these kinds of load have high inertia with large oscillation when starting, and the motor may have deceleration energy recovery. So we should use higher capacity VFD to speed up the starting to avoid oscillation. And we can use the brake unit to eliminate the feedback power.

Running a single phase motor with VFD

In this video, ATO will show you details about running a single phase motor on a VFD. It's important to note that there are two wiring methods for single phase motor connecting to ATO single phase VFD: wiring of removing motor capacitor & wiring of keeping motor capacitor. At first, you should choose the wiring method you needed, and then set basic parameters step by step.

Four Ways to Control VFD with PLC

This video introduces the main wiring methods between PLC and VFD, including digital control, analog control, serial communication and Ethernet connection. The choice of connection method depends on the specific application requirements, system complexity, cost considerations and the need for control accuracy and flexibility.

How to Choose a VFD for Your Motor?

In this video, we lay out a list of key factors that should guide you in choosing the right VFD for your motor or any other possible application.

VFD analog input 0-10V frequency control (VI port)

Single-phase Output VFD Controls Single-phase Motor Speed

This video shows the details of using a frequency converter to run a single-phase motor on a single-phase power supply. Including wiring, parameter setting, single-phase motor speed control, etc.

Product reviews
Excellent VFD
5
Matthias
Avatar
7/18/2019 9:47 PM
This is my second purchase of the ATO VFD motor controller. Both are installed and performing. Works great and I highly recommend.
Was this review helpful? Yes No (0/0)
Use of 1/2 hp VFD
5
Mary
Avatar
5/6/2021 11:49 PM
Could your 1/2 hp VFDs be supplied in explosion proof panels for offshore working conditions?
Was this review helpful? Yes No (0/0)
ATO Responded
No, we engaged in VFDs only, don't provide panels. But you can use simple local enclosure/panel if needed.
Power of one phase variable frequency drive
5
Bdeko
Avatar
5/13/2021 12:43 AM
Do we have to derate the one phase variable frequency drive?
Was this review helpful? Yes No (0/0)
ATO Responded
Just 15-20% will be enough.
High quality 1/2hp VFD
5
Calitri
Avatar
6/27/2021 9:51 PM
Could your 1/2 hp (0.4 kW) VFD, single phase input
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course.
If you need more detailed information to purchase a VFD, please let me know.
5
Dahl
Avatar
11/16/2021 11:10 PM
I am attaching you the details requested by you. Ok what is your 1-phase motor rated voltage and current? 230V, 1-Ph, 50Hz, 5 A. Motor wattage: 1100 W. And what is your 1-phase supply voltage?
230 V, 1 ph supply available. Do let me know if you require any more details.
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, recommended VFD model: GK3000-1S0015, 2hp capacity.
See its specs/price, and you can order online by credit card on: https://www.ato.com/2hp-vfd-single-phase-input-output.
I am interested in your VFD
5
Sommesi
Avatar
11/18/2021 8:17 PM
Hello, I am interested in more information about the GK3300 series of VFD drives, non-enclosed. Could you provide a manual for this series? I found a manual for the GK3000 series and imagine many things are similar. However, the main thing I wonder is how they are set up since it looks like there is no control readout, buttons or other manual inputs. Is this done with a configuration software maybe? Please let me know what info you can provide regarding this series.
Was this review helpful? Yes No (0/0)
ATO Responded
If you purchase the frequency converter non-enclosed, it will be equipped with a keyboard to realize input and display the reading function.
Installation of a 1-phase drive
5
Kurt
Avatar
2/7/2022 8:20 PM
What is the advantage of removing motor capacitors when installing your 1-phase drive?
Was this review helpful? Yes No (0/0)
ATO Responded
It is okay to remove the capcitors or not, the drive will work effectively. Just removing the capacitor may provide a little bit stability.
Can the output of this SKU: GK3000-1S0004 VFD also do single phase 120V?
5
Alex
Avatar
3/10/2022 11:19 PM
Can the output of this SKU: GK3000-1S0004 VFD also do single phase 120V? I have single phase 120V input and need single phase 120V output.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, it can't. This VFD, Single Phase Input&Output can only surport 220v input and output.
Do you ship to the EU?
5
carver
Avatar
2/28/2023 11:06 PM
Thank you for providing the link to the video.
No, we don’t want to power our linear alternator directly from the grid, then we have no control over the operation of the unit.
I think your company is located in the USA, do you ship to the EU?
Was this review helpful? Yes No (0/0)
ATO Responded
OK, I see. So you want to use VFD to control this linear alternator.
But we don't confirm whether our VFD is fully compatible with this type of motor, you can try to buy one for testing.
At present, we can only ship from the US warehouse, and other places do not support it for the time being.
How to increase the speed of the motor?
5
Alston
Avatar
2/28/2023 11:31 PM
I received this item that you recommended for my motor. Can you please send me a simple way to get to the control function so I can access how to increase the speed of the motor. Just a simple procedure as to where to navigate in the menu so I can increase the speed of the motor.
Was this review helpful? Yes No (0/0)
ATO Responded
Please refer to our video and quick setup manual.
Video: https://na01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3Ds6tTQdAVliM%26list%3DPLlo8RulDRnthBFbP4ydheukDSKw2hAfDn%26index%3D17&data=05%7C01%7C
Manual: https://www.ato.com/Content/doc/VFD-quick-setup-manual-and-application.pdf    
Please feel free to let us know if you have any further questions.
The right VFD pressure sensor parameter
5
foster
Avatar
3/2/2023 12:53 AM
I Installed this VFD GK3000. Cannot get the pressure sensor parameter right. In my unit there is a OULD PT-306 sensor and it is working fine. I connected it to the 24v for positive and CI for negative and a jumper from GND to COM. Like the You Tube video shows.
I go to you tube and try what they do. I want to start compressor and charge to 170LBS. And shut off and then restart at 150LBS to recharge to 170LBS automatically.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Connect the pressure sensor, please refer to the attachment. If you still can't connect, please provide us with your pressure sensor parameters and information.
2. How do you control the air compressor with VFD? Please provide the wiring diagram and nameplate diagram of the compressor.
3. If the VFD needs to set the frequency to 60hz, please set the parameters: P0.02=60, P0.06=60, P0.07=60, P0.19=60, P0.20=60.
Schematics diagrams for VFD
5
patryk
Avatar
7/26/2023 8:30 PM
Hello, can you provide me with the schematics diagrams
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry for the late response.
For the schematics diagrams, do you mean the electrical schematics inside the VFD?
Unfortunately, we do not provide VFD internal circuit diagram.
If you just want to change parts, just remove the original parts from the board and solder them again.
Where the OC connector is in the VFD?
5
Diggy
Avatar
8/2/2023 12:32 AM
I purchased this VFD, and in the user manual, there is an open collector output (OC), but I can't find the OC connector in the VFD. Please kindly advise where the OC connector is in the VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
Only the 380V version of our VFD is equipped with OC output terminal. What function do you want to use the OC output terminal to achieve?
Quite good
3
Jorge
Avatar
10/2/2023 5:33 PM
The VFD worked perfectly during the first week, however I had a problem when connecting to an oscilloscope and theres now an error called "P01" and "P03". I don't know how to fix it so it can operate again.
Was this review helpful? Yes No (0/0)
ATO Responded
Please send a photo of your VFD nameplate to support@ato.com (to identify your VFD version) and describe your problem, and our after-sales engineers will solve it for you.
how to fix it
5
jacob
Avatar
11/6/2023 1:05 AM
2 months ago I bought and VFD to use with a single phase motor. The VFD worked perfectly during the first week, however I had a problem when connecting to an oscilloscope and theres now an error called "P01" and "P03". I don't know how to fix it so it can operate again.
Was this review helpful? Yes No (0/0)
ATO Responded
Since our VFD has an update, this is why we ask you to send a picture of the VFD nameplate label. Please send the VFD nameplate label picture to us again for confirmation.
If your VFD serial number has the word 9000 in front of it, then to restore the VFD to factory settings, please set Pd.01=1.
After completion, you can refer to the attached quick setup document to reset the VFD parameters, and test again.
how to fix it?
5
alfor
Avatar
11/7/2023 11:33 PM
I haven't received an answer after I uploaded the data needed to identify my VFD, and now it won't start any kind of programm. When I wire and plug it in, it directly says "E-003", not allowing me to change any parameter. I hope I can receive a response, or maybe instructions to make the warranty valid.
Was this review helpful? Yes No (0/0)
ATO Responded
E03 fault is overcurrent protection.
Please follow the troubleshooting steps below to check:
1. The VFD is not connected to the motor, and the VFD is connected to the power supply. Check whether the VFD can display normally and operate normally when it is No-load?
2. Please send us the nameplate pictures of the VFD & motor to confirm if they match?
3. If step 1 proves that the VFD can operate normally without load, please connect the motor again, refer to the attached document, reset the VFD parameters, pay attention to setting the acceleration and deceleration time to P0.12=P0.13=10s, and test again.
If still If you have any questions, please provide a video for us to confirm.  It is important for us to figure out a solution. Thank you for your understanding.
Can you help me navigate the warranty situation?
5
Carter
Avatar
11/27/2023 7:25 PM
We purchased the 75 hp (55 kW) VFD, 3 Phase 230V, 440V, 480VVFD. Yesterday it quit working. It had been working well prior to this. Can you help me navigate the warranty situation?
Was this review helpful? Yes No (0/0)
ATO Responded
The warranty period of the VFD you purchased is 18 months, and it is still within the warranty period. Please do not worry, could you please tell us what the fault code displayed by the VFD is? Can you remove the motor's wiring and run the VFD alone to check if it displays and operates normally? If Not, you can set P3.01=10 (restore factory parameters), and test again.
I need a VFD
4
Reedy
Avatar
7/5/2024 3:12 AM
I have a 115V AC single phase 60Hz water pump. The only other ratings I have for it are 117W, 1Amp. I would like to control the speed of this pump remotely. I have been looking for a VFD that would work for it but they are few and far between. Can you point me to a VFD that will work for my 115V AC, 1A, single phase, 60Hz water pump?
Was this review helpful? Yes No (0/0)
ATO Responded
You can choose our single-phase VFD model GK3000-1S0004, Link: https://www.ato.com/1-2hp-vfd-single-phase-input-output
Its input voltage is single-phase 220V, the output voltage is 0-220V, and the output voltage can be set to 115V. It would be better if you can provide us with the motor nameplate of your pump.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1/2 hp variable frequency drive, 0.4 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0004
Capacity1/2 hp (0.4 kW)
Shipping weight2 kg
Dimension142*85*110 mm
I/O FeatureRated current4 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequency0~1000Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Start frequency0.40Hz~20.00Hz
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuating
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
  4. If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.

Details

400W Single Phase VFD Details
Tips: 7 points about variable frequency drive application environment
The variable frequency drive may not be normally operated in any cases, so the user is necessary to have more understanding about load, environmental requirements and the VFD itself. There are seven points should be pay attention to:

  1. Because the motor temperature will be high under long-term and low-speed operation, the fan cooling capacity will also reduce, so it must use high reduction ratio VFD or 6 grade motor to let the motor running in higher frequency.
  2. The variable frequency drive installation site must require the standard environment, or it will easily cause failure or shorten the service life. The distance between VFD and driving motor should not be more than 50 meters, for longer distances need to reduce the carrier frequency or increase output reactor option to function properly.
  3. Type of load and VFD selection: Different load of motor has different requirements of VFD.
  4. Fan and pump is the most common load: They have the simplest requirements of the variable frequency drive, as long as the variable frequency drive capacity is equal to the motor capacity (air compressor, deep water pump, sediment pump, and fast changing music fountain need higher capacity).
  5. Crane load: This type of load is characterized by a great impact on the starting, so it requires a margin of the VFD. At the same time, there will be energy feedback when putting down the weight, so it requires brake unit or share bus.
  6. Uneven load: Some load maybe sometimes light and sometimes heavy, this time should be in accordance with the heavy load situation to select the variable frequency drive capacity, such as rolling machinery, crushing machinery, mixer, etc.
  7. High inertia load: Such as centrifuges, punching presses, cement rotary kiln, these kinds of load have high inertia with large oscillation when starting, and the motor may have deceleration energy recovery. So we should use higher capacity VFD to speed up the starting to avoid oscillation. And we can use the brake unit to eliminate the feedback power.
Product reviews
Excellent VFD
5
Matthias
Avatar
7/18/2019 9:47 PM
This is my second purchase of the ATO VFD motor controller. Both are installed and performing. Works great and I highly recommend.
Was this review helpful? Yes No (0/0)
Use of 1/2 hp VFD
5
Mary
Avatar
5/6/2021 11:49 PM
Could your 1/2 hp VFDs be supplied in explosion proof panels for offshore working conditions?
Was this review helpful? Yes No (0/0)
ATO Responded
No, we engaged in VFDs only, don't provide panels. But you can use simple local enclosure/panel if needed.
Power of one phase variable frequency drive
5
Bdeko
Avatar
5/13/2021 12:43 AM
Do we have to derate the one phase variable frequency drive?
Was this review helpful? Yes No (0/0)
ATO Responded
Just 15-20% will be enough.
High quality 1/2hp VFD
5
Calitri
Avatar
6/27/2021 9:51 PM
Could your 1/2 hp (0.4 kW) VFD, single phase input
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course.
If you need more detailed information to purchase a VFD, please let me know.
5
Dahl
Avatar
11/16/2021 11:10 PM
I am attaching you the details requested by you. Ok what is your 1-phase motor rated voltage and current? 230V, 1-Ph, 50Hz, 5 A. Motor wattage: 1100 W. And what is your 1-phase supply voltage?
230 V, 1 ph supply available. Do let me know if you require any more details.
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, recommended VFD model: GK3000-1S0015, 2hp capacity.
See its specs/price, and you can order online by credit card on: https://www.ato.com/2hp-vfd-single-phase-input-output.
I am interested in your VFD
5
Sommesi
Avatar
11/18/2021 8:17 PM
Hello, I am interested in more information about the GK3300 series of VFD drives, non-enclosed. Could you provide a manual for this series? I found a manual for the GK3000 series and imagine many things are similar. However, the main thing I wonder is how they are set up since it looks like there is no control readout, buttons or other manual inputs. Is this done with a configuration software maybe? Please let me know what info you can provide regarding this series.
Was this review helpful? Yes No (0/0)
ATO Responded
If you purchase the frequency converter non-enclosed, it will be equipped with a keyboard to realize input and display the reading function.
Installation of a 1-phase drive
5
Kurt
Avatar
2/7/2022 8:20 PM
What is the advantage of removing motor capacitors when installing your 1-phase drive?
Was this review helpful? Yes No (0/0)
ATO Responded
It is okay to remove the capcitors or not, the drive will work effectively. Just removing the capacitor may provide a little bit stability.
Can the output of this SKU: GK3000-1S0004 VFD also do single phase 120V?
5
Alex
Avatar
3/10/2022 11:19 PM
Can the output of this SKU: GK3000-1S0004 VFD also do single phase 120V? I have single phase 120V input and need single phase 120V output.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, it can't. This VFD, Single Phase Input&Output can only surport 220v input and output.
Do you ship to the EU?
5
carver
Avatar
2/28/2023 11:06 PM
Thank you for providing the link to the video.
No, we don’t want to power our linear alternator directly from the grid, then we have no control over the operation of the unit.
I think your company is located in the USA, do you ship to the EU?
Was this review helpful? Yes No (0/0)
ATO Responded
OK, I see. So you want to use VFD to control this linear alternator.
But we don't confirm whether our VFD is fully compatible with this type of motor, you can try to buy one for testing.
At present, we can only ship from the US warehouse, and other places do not support it for the time being.
How to increase the speed of the motor?
5
Alston
Avatar
2/28/2023 11:31 PM
I received this item that you recommended for my motor. Can you please send me a simple way to get to the control function so I can access how to increase the speed of the motor. Just a simple procedure as to where to navigate in the menu so I can increase the speed of the motor.
Was this review helpful? Yes No (0/0)
ATO Responded
Please refer to our video and quick setup manual.
Video: https://na01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fwww.youtube.com%2Fwatch%3Fv%3Ds6tTQdAVliM%26list%3DPLlo8RulDRnthBFbP4ydheukDSKw2hAfDn%26index%3D17&data=05%7C01%7C
Manual: https://www.ato.com/Content/doc/VFD-quick-setup-manual-and-application.pdf    
Please feel free to let us know if you have any further questions.
The right VFD pressure sensor parameter
5
foster
Avatar
3/2/2023 12:53 AM
I Installed this VFD GK3000. Cannot get the pressure sensor parameter right. In my unit there is a OULD PT-306 sensor and it is working fine. I connected it to the 24v for positive and CI for negative and a jumper from GND to COM. Like the You Tube video shows.
I go to you tube and try what they do. I want to start compressor and charge to 170LBS. And shut off and then restart at 150LBS to recharge to 170LBS automatically.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Connect the pressure sensor, please refer to the attachment. If you still can't connect, please provide us with your pressure sensor parameters and information.
2. How do you control the air compressor with VFD? Please provide the wiring diagram and nameplate diagram of the compressor.
3. If the VFD needs to set the frequency to 60hz, please set the parameters: P0.02=60, P0.06=60, P0.07=60, P0.19=60, P0.20=60.
Schematics diagrams for VFD
5
patryk
Avatar
7/26/2023 8:30 PM
Hello, can you provide me with the schematics diagrams
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry for the late response.
For the schematics diagrams, do you mean the electrical schematics inside the VFD?
Unfortunately, we do not provide VFD internal circuit diagram.
If you just want to change parts, just remove the original parts from the board and solder them again.
Where the OC connector is in the VFD?
5
Diggy
Avatar
8/2/2023 12:32 AM
I purchased this VFD, and in the user manual, there is an open collector output (OC), but I can't find the OC connector in the VFD. Please kindly advise where the OC connector is in the VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
Only the 380V version of our VFD is equipped with OC output terminal. What function do you want to use the OC output terminal to achieve?
Quite good
3
Jorge
Avatar
10/2/2023 5:33 PM
The VFD worked perfectly during the first week, however I had a problem when connecting to an oscilloscope and theres now an error called "P01" and "P03". I don't know how to fix it so it can operate again.
Was this review helpful? Yes No (0/0)
ATO Responded
Please send a photo of your VFD nameplate to support@ato.com (to identify your VFD version) and describe your problem, and our after-sales engineers will solve it for you.
how to fix it
5
jacob
Avatar
11/6/2023 1:05 AM
2 months ago I bought and VFD to use with a single phase motor. The VFD worked perfectly during the first week, however I had a problem when connecting to an oscilloscope and theres now an error called "P01" and "P03". I don't know how to fix it so it can operate again.
Was this review helpful? Yes No (0/0)
ATO Responded
Since our VFD has an update, this is why we ask you to send a picture of the VFD nameplate label. Please send the VFD nameplate label picture to us again for confirmation.
If your VFD serial number has the word 9000 in front of it, then to restore the VFD to factory settings, please set Pd.01=1.
After completion, you can refer to the attached quick setup document to reset the VFD parameters, and test again.
how to fix it?
5
alfor
Avatar
11/7/2023 11:33 PM
I haven't received an answer after I uploaded the data needed to identify my VFD, and now it won't start any kind of programm. When I wire and plug it in, it directly says "E-003", not allowing me to change any parameter. I hope I can receive a response, or maybe instructions to make the warranty valid.
Was this review helpful? Yes No (0/0)
ATO Responded
E03 fault is overcurrent protection.
Please follow the troubleshooting steps below to check:
1. The VFD is not connected to the motor, and the VFD is connected to the power supply. Check whether the VFD can display normally and operate normally when it is No-load?
2. Please send us the nameplate pictures of the VFD & motor to confirm if they match?
3. If step 1 proves that the VFD can operate normally without load, please connect the motor again, refer to the attached document, reset the VFD parameters, pay attention to setting the acceleration and deceleration time to P0.12=P0.13=10s, and test again.
If still If you have any questions, please provide a video for us to confirm.  It is important for us to figure out a solution. Thank you for your understanding.
Can you help me navigate the warranty situation?
5
Carter
Avatar
11/27/2023 7:25 PM
We purchased the 75 hp (55 kW) VFD, 3 Phase 230V, 440V, 480VVFD. Yesterday it quit working. It had been working well prior to this. Can you help me navigate the warranty situation?
Was this review helpful? Yes No (0/0)
ATO Responded
The warranty period of the VFD you purchased is 18 months, and it is still within the warranty period. Please do not worry, could you please tell us what the fault code displayed by the VFD is? Can you remove the motor's wiring and run the VFD alone to check if it displays and operates normally? If Not, you can set P3.01=10 (restore factory parameters), and test again.
I need a VFD
4
Reedy
Avatar
7/5/2024 3:12 AM
I have a 115V AC single phase 60Hz water pump. The only other ratings I have for it are 117W, 1Amp. I would like to control the speed of this pump remotely. I have been looking for a VFD that would work for it but they are few and far between. Can you point me to a VFD that will work for my 115V AC, 1A, single phase, 60Hz water pump?
Was this review helpful? Yes No (0/0)
ATO Responded
You can choose our single-phase VFD model GK3000-1S0004, Link: https://www.ato.com/1-2hp-vfd-single-phase-input-output
Its input voltage is single-phase 220V, the output voltage is 0-220V, and the output voltage can be set to 115V. It would be better if you can provide us with the motor nameplate of your pump.
Only registered users can write reviews
Customers who bought this item also bought

1 hp (0.75 kW) VFD, Single Phase Input & Output

GK3000-1S0007
$195.82
Affordable 1 hp VFD, 1 phase for single phase AC induction motor, 220V - 240V 7 amps, manufacturer direct sale.

10K Ohm Rotary Potentiometer with On Off Switch

ATO-RP-10K
$17.86
Buy low priced variable rotary potentiometers with 10K Ohm resistance from ATO.com. This on/off rotary switch potentiometer is widely used for audio, guitar, amplifiers, electric lights, other arduino based two tone device projects and more.

1 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0007
$159.32
1 hp VFD, convert single phase to three phase for AC motor speed controls, IP20, RS485 enabled, shipping weight 2kg, manufacturer direct sale.

3 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0022
$238.14
Low price 3hp VFD, convert 220V/230V/240V 1 phase to 3 phase, 9.6 amps, RS485 enabled, shipping weight 3kg, manufacturer direct sale.

Stainless-Steel Centrifugal Fan, 180W/750W/2200W, 2800 rpm

ATO-CF-Y547
$448.62
Economical price stainless steel centrifugal fan is made of high-quality stainless steel, which is rust-proof, moisture-proof and anti-oxidation. The power can be selected from 180W to 2200W, the operating speed is up to 2800 rpm, and it supports 220V and 380V voltages, with strong wind and efficient air circulation.