1/2 hp variable frequency drive, 0.4 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.
Specification:
| Basics | Model | GK3000-1S0004 |
| Capacity | 1/2 hp (0.4 kW) | |
| Shipping weight | 2 kg | |
| Dimension | 142*85*110 mm | |
| I/O Feature | Rated current | 4 A |
| Input voltage | single phase AC 220V±15% | |
| Input frequency | 47~63Hz | |
| Output voltage | 0~rated input voltage | |
| Output frequency | 0~1000Hz | |
| Over load capacity | 150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s | |
| Control Features | Control mode | V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC) |
| Operation command mode | Keypad control, Terminal control, Serial communication control | |
| Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes. | |
| Start frequency | 0.40Hz~20.00Hz | |
| Speed adjustment range | 1:50 | |
| Carrier frequency | 1.0-16.0kHz, automatically adjusted according to temperature and load characteristics | |
| Frequency accuracy | Digital setting: 0.01Hz Analog setting: Maximum frequency * 0.05% | |
| Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0% | |
| V/f curve | Three types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square) | |
| Acceleration/deceleration mode | Straight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s | |
| Jog operation | Jog operation frequency: 0.0Hz~maximum frequency Jog acceleration/deceleration time: 0.1s~3600.0s | |
| Simple PLC & multi-step speed operation | It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. | |
| Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | |
| Automatic voltage regulation | Keep output voltage constant automatically when input voltage fluctuating | |
| Control Function | Common DC bus | Common DC bus for several VFDs, energy balanced automatically |
| Torque control | Torque control without PG | |
| Torque limit | "Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process | |
| Wobble frequency control | Multiple triangular-wave frequency control, special for textile | |
| Timing/length/counting control | Timing/length/counting control function | |
| Over-voltage & over-current stall control | Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping | |
| Fault protection function | Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function | |
| Input/output terminals | Input terminals | Programmable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI: AI1: 0~10V or 0/4~20mA A12: 0~10V or 0/4~20mA |
| Output terminals | 1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output) 2 relay output 2 analog output: 0/4~20mA or 0~10V | |
| Communication terminals | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |
| Human machine interface | LED display | Display frequency setting, output frequency, output voltage, output current, etc. |
| Multifunction key | QUICK/JOG key, can be used as multifunction key | |
| Environment | Ambient temperature | -10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃). |
| Humidity | 90%RH or less (non-condensing) | |
| Altitude | ≤1000M: Output rated power, >1000M: Output derated | |
| Storage temperature | -20℃~60℃ |
Note:
- The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
- ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
- Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
- If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.
Details

Tips: 7 points about variable frequency drive application environment
The variable frequency drive may not be normally operated in any cases, so the user is necessary to have more understanding about load, environmental requirements and the VFD itself. There are seven points should be pay attention to:
- Because the motor temperature will be high under long-term and low-speed operation, the fan cooling capacity will also reduce, so it must use high reduction ratio VFD or 6 grade motor to let the motor running in higher frequency.
- The variable frequency drive installation site must require the standard environment, or it will easily cause failure or shorten the service life. The distance between VFD and driving motor should not be more than 50 meters, for longer distances need to reduce the carrier frequency or increase output reactor option to function properly.
- Type of load and VFD selection: Different load of motor has different requirements of VFD.
- Fan and pump is the most common load: They have the simplest requirements of the variable frequency drive, as long as the variable frequency drive capacity is equal to the motor capacity (air compressor, deep water pump, sediment pump, and fast changing music fountain need higher capacity).
- Crane load: This type of load is characterized by a great impact on the starting, so it requires a margin of the VFD. At the same time, there will be energy feedback when putting down the weight, so it requires brake unit or share bus.
- Uneven load: Some load maybe sometimes light and sometimes heavy, this time should be in accordance with the heavy load situation to select the variable frequency drive capacity, such as rolling machinery, crushing machinery, mixer, etc.
- High inertia load: Such as centrifuges, punching presses, cement rotary kiln, these kinds of load have high inertia with large oscillation when starting, and the motor may have deceleration energy recovery. So we should use higher capacity VFD to speed up the starting to avoid oscillation. And we can use the brake unit to eliminate the feedback power.
Product reviews
Excellent VFD
Matthias
7/18/2019 9:47 PM
This is my second purchase of the ATO VFD motor controller. Both are installed and performing. Works great and I highly recommend.
Was this review helpful? (0/0)
Use of 1/2 hp VFD
Mary
5/6/2021 11:49 PM
Could your 1/2 hp VFDs be supplied in explosion proof panels for offshore working conditions?
Was this review helpful? (0/0)
Power of one phase variable frequency drive
Bdeko
5/13/2021 12:43 AM
Do we have to derate the one phase variable frequency drive?
Was this review helpful? (0/0)
High quality 1/2hp VFD
Calitri
6/27/2021 9:51 PM
Could your 1/2 hp (0.4 kW) VFD, single phase input
Was this review helpful? (0/0)
If you need more detailed information to purchase a VFD, please let me know.
Dahl
11/16/2021 11:10 PM
I am attaching you the details requested by you. Ok what is your 1-phase motor rated voltage and current? 230V, 1-Ph, 50Hz, 5 A. Motor wattage: 1100 W. And what is your 1-phase supply voltage?
230 V, 1 ph supply available. Do let me know if you require any more details.
230 V, 1 ph supply available. Do let me know if you require any more details.
Was this review helpful? (0/0)
I am interested in your VFD
Sommesi
11/18/2021 8:17 PM
Hello, I am interested in more information about the GK3300 series of VFD drives, non-enclosed. Could you provide a manual for this series? I found a manual for the GK3000 series and imagine many things are similar. However, the main thing I wonder is how they are set up since it looks like there is no control readout, buttons or other manual inputs. Is this done with a configuration software maybe? Please let me know what info you can provide regarding this series.
Was this review helpful? (0/0)
Installation of a 1-phase drive
Kurt
2/7/2022 8:20 PM
What is the advantage of removing motor capacitors when installing your 1-phase drive?
Was this review helpful? (0/0)
Can the output of this SKU: GK3000-1S0004 VFD also do single phase 120V?
Alex
3/10/2022 11:19 PM
Can the output of this SKU: GK3000-1S0004 VFD also do single phase 120V? I have single phase 120V input and need single phase 120V output.
Was this review helpful? (0/0)
Do you ship to the EU?
carver
2/28/2023 11:06 PM
Thank you for providing the link to the video.
No, we don’t want to power our linear alternator directly from the grid, then we have no control over the operation of the unit.
I think your company is located in the USA, do you ship to the EU?
No, we don’t want to power our linear alternator directly from the grid, then we have no control over the operation of the unit.
I think your company is located in the USA, do you ship to the EU?
Was this review helpful? (0/0)
How to increase the speed of the motor?
Alston
2/28/2023 11:31 PM
I received this item that you recommended for my motor. Can you please send me a simple way to get to the control function so I can access how to increase the speed of the motor. Just a simple procedure as to where to navigate in the menu so I can increase the speed of the motor.
Was this review helpful? (0/0)
The right VFD pressure sensor parameter
foster
3/2/2023 12:53 AM
I Installed this VFD GK3000. Cannot get the pressure sensor parameter right. In my unit there is a OULD PT-306 sensor and it is working fine. I connected it to the 24v for positive and CI for negative and a jumper from GND to COM. Like the You Tube video shows.
I go to you tube and try what they do. I want to start compressor and charge to 170LBS. And shut off and then restart at 150LBS to recharge to 170LBS automatically.
I go to you tube and try what they do. I want to start compressor and charge to 170LBS. And shut off and then restart at 150LBS to recharge to 170LBS automatically.
Was this review helpful? (0/0)
Schematics diagrams for VFD
patryk
7/26/2023 8:30 PM
Hello, can you provide me with the schematics diagrams
Was this review helpful? (0/0)
Where the OC connector is in the VFD?
Diggy
8/2/2023 12:32 AM
I purchased this VFD, and in the user manual, there is an open collector output (OC), but I can't find the OC connector in the VFD. Please kindly advise where the OC connector is in the VFD?
Was this review helpful? (0/0)
Quite good
Jorge
10/2/2023 5:33 PM
The VFD worked perfectly during the first week, however I had a problem when connecting to an oscilloscope and theres now an error called "P01" and "P03". I don't know how to fix it so it can operate again.
Was this review helpful? (0/0)
how to fix it
jacob
11/6/2023 1:05 AM
2 months ago I bought and VFD to use with a single phase motor. The VFD worked perfectly during the first week, however I had a problem when connecting to an oscilloscope and theres now an error called "P01" and "P03". I don't know how to fix it so it can operate again.
Was this review helpful? (0/0)
how to fix it?
alfor
11/7/2023 11:33 PM
I haven't received an answer after I uploaded the data needed to identify my VFD, and now it won't start any kind of programm. When I wire and plug it in, it directly says "E-003", not allowing me to change any parameter. I hope I can receive a response, or maybe instructions to make the warranty valid.
Was this review helpful? (0/0)
Can you help me navigate the warranty situation?
Carter
11/27/2023 7:25 PM
We purchased the 75 hp (55 kW) VFD, 3 Phase 230V, 440V, 480VVFD. Yesterday it quit working. It had been working well prior to this. Can you help me navigate the warranty situation?
Was this review helpful? (0/0)
I need a VFD
Reedy
7/5/2024 3:12 AM
I have a 115V AC single phase 60Hz water pump. The only other ratings I have for it are 117W, 1Amp. I would like to control the speed of this pump remotely. I have been looking for a VFD that would work for it but they are few and far between. Can you point me to a VFD that will work for my 115V AC, 1A, single phase, 60Hz water pump?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
1 hp (0.75 kW) VFD, Single Phase Input & Output
GK3000-1S0007
$195.82
Affordable 1 hp VFD, 1 phase for single phase AC induction motor, 220V - 240V 7 amps, manufacturer direct sale.
10K Ohm Rotary Potentiometer with On Off Switch
ATO-RP-10K
$17.86
Buy low priced variable rotary potentiometers with 10K Ohm resistance from ATO.com. This on/off rotary switch potentiometer is widely used for audio, guitar, amplifiers, electric lights, other arduino based two tone device projects and more.
1 hp VFD, Single Phase to Three Phase VFD
GK3000-2S0007
$159.32
1 hp VFD, convert single phase to three phase for AC motor speed controls, IP20, RS485 enabled, shipping weight 2kg, manufacturer direct sale.
3 hp VFD, Single Phase to Three Phase VFD
GK3000-2S0022
$238.14
Low price 3hp VFD, convert 220V/230V/240V 1 phase to 3 phase, 9.6 amps, RS485 enabled, shipping weight 3kg, manufacturer direct sale.
Stainless-Steel Centrifugal Fan, 180W/750W/2200W, 2800 rpm
ATO-CF-Y547
$448.62
Economical price stainless steel centrifugal fan is made of high-quality stainless steel, which is rust-proof, moisture-proof and anti-oxidation. The power can be selected from 180W to 2200W, the operating speed is up to 2800 rpm, and it supports 220V and 380V voltages, with strong wind and efficient air circulation.