5 hp (4 kW) VFD, Single Phase Input & Output

$649.54
Low cost 5 hp VFD, 1 phase for single phase AC motor speed controls, 220V - 240V 25 amps, manufacturer direct sale.
SKU: GK3000-1S0037
Availability: In stock
Free Shipping
Delivery date: 2-3 days

5 hp variable frequency drive, 4 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0037
Capacity5 hp (4 kW)
Shipping weight8 kg
Dimension (H*W*D)330*200*200 mm
I/O FeatureRated current25 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequency0~1000Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Start frequency0.40Hz~20.00Hz
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuating
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
  4. If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.

Details

4000W Single Phase VFD Details
Tips: Six attentions of installing VFD in automatic control system

  1. For the frequency given signal should be used as far as possible 4-20mA international standard signal. Should make sure the signal line shield ground, to avoid the interference signal into the VFD. The production site has an interference signal, the interference signal will affect the stability of the control, so need to use input filter, and set its range to be 0.00-5.00s. If using VFD built-in PID function should use the feedback filter to increase the control stability of the built-in PID, the setting range is 0.0-60s. However, it should be noted that the filter time is set too long, the control is stable, but the system response is worse; the filter time is set too short, the system response is fast, but the control is unstable. So it should be based on the actual scene to make adjustments.
  2. To set the corresponding manual, automatic switching operating function. Optional manual, automatic, forced manual functions of manual operator. If necessary, could also consider the redundant operation function of the current and voltage setting, that is, the VFD frequency setting signal use current setting in normal, using voltage setting in abnormal manual operation. That is, add a potentiometer for setting g the VFD frequency, so the VFD frequency reference signal has two types, current signal and voltage signal. Because there are two types of frequency setting signals input in the VFD, increasing its redundancy degree.
  3. Must set the "overhaul switch", that is, set the "on-site overhaul switch" next to the operating equipment, when switch it to the "overhaul" position, equal to cut off the VFD running signal circuit. If someone misuse, the equipment can't run, to ensure that the safety of mechanical equipment maintainer.
  4. Make full use of the VFD input and output control terminals function, to carry out some alarm and interlock function, to reduce wiring and improve reliability.
  5. For single or simple control system, can take full advantage of the VFD built-in PID control function to reduce the control system equipments and reduce investment.
  6. Some VFD have input terminals R0, T0 of control power. So should connect control power to VFD R0, T0 side in front of the main power supply. So that the VFD still has a display function after the trip, in order to analyze the cause of the malfunction and take countermeasures.

Running a single phase motor with VFD

In this video, ATO will show you details about running a single phase motor on a VFD. It's important to note that there are two wiring methods for single phase motor connecting to ATO single phase VFD: wiring of removing motor capacitor & wiring of keeping motor capacitor. At first, you should choose the wiring method you needed, and then set basic parameters step by step.

Four Ways to Control VFD with PLC

This video introduces the main wiring methods between PLC and VFD, including digital control, analog control, serial communication and Ethernet connection. The choice of connection method depends on the specific application requirements, system complexity, cost considerations and the need for control accuracy and flexibility.

How to Choose a VFD for Your Motor?

In this video, we lay out a list of key factors that should guide you in choosing the right VFD for your motor or any other possible application.

VFD analog input 0-10V frequency control (VI port)

Single-phase Output VFD Controls Single-phase Motor Speed

This video shows the details of using a frequency converter to run a single-phase motor on a single-phase power supply. Including wiring, parameter setting, single-phase motor speed control, etc.

Product reviews
Dominican Republic representative
5
Oscar
Avatar
4/27/2018 12:36 AM
Do you have a representative in the Dominican Republic where I can purchase this 5hp VFD for single-phase motor use?
Was this review helpful? Yes No (0/0)
ATO Responded
No, but you can purchase the VFD from us directly, ATO can ship it internationally, free of charge.
Good 5hp single phase VFD
5
Irene
Avatar
4/20/2021 9:01 PM
For your 5hp single phase frequncy drive, does this keep the motor in it’s torque capability at low speed?
Was this review helpful? Yes No (0/0)
ATO Responded
There are constant torque VFDs, but for the 5hp single phase VFD, it's not, the torque will reduce along with the speed.
Good single phase VFD
5
Agrawal
Avatar
6/3/2021 12:33 AM
Do you offer external potentiometer for external speed controls for your single phase drive?
Was this review helpful? Yes No (0/0)
ATO Responded
Our single VFD has a potentiometer beside its operation panel, and also you can install external one if needed.
My question about single VFD
5
Rizzo
Avatar
10/31/2021 8:54 PM
What communications can your 1-phase drive handle? Analog input? Can it be directly communicated with by most PLCs?
Was this review helpful? Yes No (0/0)
ATO Responded
You can use the analog signal of the PLC.
I am interested in your single phase VFD
5
Palli
Avatar
1/4/2022 12:27 AM
I am interested in the single phase output drives. Can I operate more than one fan motor on one drive?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can. But run all at the same instant from the drive.
Questions about 1-phase VFD
5
Patty
Avatar
1/9/2022 8:41 PM
Do I unhook the start/run capacitors when connecting your 1-phase VFD to my 1-phase motor?
Was this review helpful? Yes No (0/0)
ATO Responded
No, you can keep the capacitors.
Just want to be absolutely clear before wiring everything up.
5
Randolph
Avatar
7/27/2022 1:48 AM
Keep the R, S, and T terminals wired how it originally came, got it. And to confirm, the green wire going internally into the VFD IS grounded? So no need to attach anything to the E ground terminal? For the green and red wires, am I correct in saying you've attached the green wire to the white wire coming from the power supply cable, and the red wire to a black wire? Then these 2 wires have a 2 prong plug attached that goes into a wall outlet? And what's the green wire resting on the side of the VFD do?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, please keep the R, S and T terminals wired the way they are. The green wire is N and the red L, you can see the number on the cable. The green and red wires (L, N) are directly connected to your 120V input power supply, and AC power does not need to distinguish between the live and neutral wires. The E on the terminal can be connected to the input power ground wire G.
Questions about 5HP VFD
5
Jaeden
Avatar
3/3/2023 12:18 AM
Is the internal fan on the 5HP VFD supposed to run all the time the pump motor is running? Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
As long as the 5HP VFD is running, the fan will automatically run; when the VFD is stopped, the fan will also stop. So if the VFD is running, but the fan is not, then there is something wrong with the fan.
Do you have electrical plug wiring picture of VFD?
5
ronnie
Avatar
6/6/2023 2:48 AM
I have one question. We received the pump and the VFD.
I checked in the lab that we have the electrical plug NEMA 6-30, 208VAC, 30A single phase, with three wire.
As per the instruction manual to wire the VFD on 220V single phase, the picture (page 30) showed connection for only two wires.
Do you have the wire schematic to wire on the electrical plug NEMA 6-30, 208VAC, 30A single phase? I appreciate if you can help.
In advance, thank you for your time and help.
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD models you purchased are GK3000-1S0022 and GK3000-1S0037. The power supply is connected to the two terminals of the reserved screws in the input terminals R, S, T.
The terminal with the screw removed is not used, and the terminal marked E is the ground wire.
Any two terminals of output terminals U, V, W can be connected to a single-phase 220V motor.
You can refer to this demo video: https://www.youtube.com/watch?v=D8zavX-9vVw&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=15
Hope my explanation is able to assist you. Please feel free to let us know if you have any further questions.
Single phase VFD diagram
5
blanche
Avatar
6/7/2023 1:00 AM
We are currently using this wearing diagram. With u we are at 6.75 amps with v we are at 22 amps and with w we are at 35 amps, which is too many amps.
Was this review helpful? Yes No (0/0)
ATO Responded
We think that after you removed the cable of the single-phase motor and changed it to three wires, the internal winding structure of the motor was unbalanced and the current of phase C was too high.
We suggest that you restore the internal wiring and capacitors of the single-phase motor to the original, and then you only need to connect the 2 wires of the single-phase motor to U,W of the VFD output terminal.
Please reset the parameters according to the parameter setting instructions of the attached single-phase motor, and test again.
Hope my explanation is able to assist you. Please feel free to let us know if you have any further questions.
Question about GK3000-1S0037
5
Cosmin
Avatar
2/21/2024 8:22 PM
I have two of these drives and I'm trying to run a three phase motor. Will it work or this can only do single phase in and single phase out? Thank you much.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can output 3 phases. If the process meets other problems you can contact our after-sales: support@ato.com.
PREGUNTA
5
ELLIOT
Avatar
6/25/2024 8:22 AM
ESTE VARIADOR DE FRECUENCIA SIRVE PARA MOTOR HERMETICOS DE COMPRESOR DE REFRIGERACION
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

5 hp variable frequency drive, 4 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0037
Capacity5 hp (4 kW)
Shipping weight8 kg
Dimension (H*W*D)330*200*200 mm
I/O FeatureRated current25 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequency0~1000Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Start frequency0.40Hz~20.00Hz
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuating
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
  4. If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.

Details

4000W Single Phase VFD Details
Tips: Six attentions of installing VFD in automatic control system

  1. For the frequency given signal should be used as far as possible 4-20mA international standard signal. Should make sure the signal line shield ground, to avoid the interference signal into the VFD. The production site has an interference signal, the interference signal will affect the stability of the control, so need to use input filter, and set its range to be 0.00-5.00s. If using VFD built-in PID function should use the feedback filter to increase the control stability of the built-in PID, the setting range is 0.0-60s. However, it should be noted that the filter time is set too long, the control is stable, but the system response is worse; the filter time is set too short, the system response is fast, but the control is unstable. So it should be based on the actual scene to make adjustments.
  2. To set the corresponding manual, automatic switching operating function. Optional manual, automatic, forced manual functions of manual operator. If necessary, could also consider the redundant operation function of the current and voltage setting, that is, the VFD frequency setting signal use current setting in normal, using voltage setting in abnormal manual operation. That is, add a potentiometer for setting g the VFD frequency, so the VFD frequency reference signal has two types, current signal and voltage signal. Because there are two types of frequency setting signals input in the VFD, increasing its redundancy degree.
  3. Must set the "overhaul switch", that is, set the "on-site overhaul switch" next to the operating equipment, when switch it to the "overhaul" position, equal to cut off the VFD running signal circuit. If someone misuse, the equipment can't run, to ensure that the safety of mechanical equipment maintainer.
  4. Make full use of the VFD input and output control terminals function, to carry out some alarm and interlock function, to reduce wiring and improve reliability.
  5. For single or simple control system, can take full advantage of the VFD built-in PID control function to reduce the control system equipments and reduce investment.
  6. Some VFD have input terminals R0, T0 of control power. So should connect control power to VFD R0, T0 side in front of the main power supply. So that the VFD still has a display function after the trip, in order to analyze the cause of the malfunction and take countermeasures.
Product reviews
Dominican Republic representative
5
Oscar
Avatar
4/27/2018 12:36 AM
Do you have a representative in the Dominican Republic where I can purchase this 5hp VFD for single-phase motor use?
Was this review helpful? Yes No (0/0)
ATO Responded
No, but you can purchase the VFD from us directly, ATO can ship it internationally, free of charge.
Good 5hp single phase VFD
5
Irene
Avatar
4/20/2021 9:01 PM
For your 5hp single phase frequncy drive, does this keep the motor in it’s torque capability at low speed?
Was this review helpful? Yes No (0/0)
ATO Responded
There are constant torque VFDs, but for the 5hp single phase VFD, it's not, the torque will reduce along with the speed.
Good single phase VFD
5
Agrawal
Avatar
6/3/2021 12:33 AM
Do you offer external potentiometer for external speed controls for your single phase drive?
Was this review helpful? Yes No (0/0)
ATO Responded
Our single VFD has a potentiometer beside its operation panel, and also you can install external one if needed.
My question about single VFD
5
Rizzo
Avatar
10/31/2021 8:54 PM
What communications can your 1-phase drive handle? Analog input? Can it be directly communicated with by most PLCs?
Was this review helpful? Yes No (0/0)
ATO Responded
You can use the analog signal of the PLC.
I am interested in your single phase VFD
5
Palli
Avatar
1/4/2022 12:27 AM
I am interested in the single phase output drives. Can I operate more than one fan motor on one drive?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can. But run all at the same instant from the drive.
Questions about 1-phase VFD
5
Patty
Avatar
1/9/2022 8:41 PM
Do I unhook the start/run capacitors when connecting your 1-phase VFD to my 1-phase motor?
Was this review helpful? Yes No (0/0)
ATO Responded
No, you can keep the capacitors.
Just want to be absolutely clear before wiring everything up.
5
Randolph
Avatar
7/27/2022 1:48 AM
Keep the R, S, and T terminals wired how it originally came, got it. And to confirm, the green wire going internally into the VFD IS grounded? So no need to attach anything to the E ground terminal? For the green and red wires, am I correct in saying you've attached the green wire to the white wire coming from the power supply cable, and the red wire to a black wire? Then these 2 wires have a 2 prong plug attached that goes into a wall outlet? And what's the green wire resting on the side of the VFD do?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, please keep the R, S and T terminals wired the way they are. The green wire is N and the red L, you can see the number on the cable. The green and red wires (L, N) are directly connected to your 120V input power supply, and AC power does not need to distinguish between the live and neutral wires. The E on the terminal can be connected to the input power ground wire G.
Questions about 5HP VFD
5
Jaeden
Avatar
3/3/2023 12:18 AM
Is the internal fan on the 5HP VFD supposed to run all the time the pump motor is running? Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
As long as the 5HP VFD is running, the fan will automatically run; when the VFD is stopped, the fan will also stop. So if the VFD is running, but the fan is not, then there is something wrong with the fan.
Do you have electrical plug wiring picture of VFD?
5
ronnie
Avatar
6/6/2023 2:48 AM
I have one question. We received the pump and the VFD.
I checked in the lab that we have the electrical plug NEMA 6-30, 208VAC, 30A single phase, with three wire.
As per the instruction manual to wire the VFD on 220V single phase, the picture (page 30) showed connection for only two wires.
Do you have the wire schematic to wire on the electrical plug NEMA 6-30, 208VAC, 30A single phase? I appreciate if you can help.
In advance, thank you for your time and help.
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD models you purchased are GK3000-1S0022 and GK3000-1S0037. The power supply is connected to the two terminals of the reserved screws in the input terminals R, S, T.
The terminal with the screw removed is not used, and the terminal marked E is the ground wire.
Any two terminals of output terminals U, V, W can be connected to a single-phase 220V motor.
You can refer to this demo video: https://www.youtube.com/watch?v=D8zavX-9vVw&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=15
Hope my explanation is able to assist you. Please feel free to let us know if you have any further questions.
Single phase VFD diagram
5
blanche
Avatar
6/7/2023 1:00 AM
We are currently using this wearing diagram. With u we are at 6.75 amps with v we are at 22 amps and with w we are at 35 amps, which is too many amps.
Was this review helpful? Yes No (0/0)
ATO Responded
We think that after you removed the cable of the single-phase motor and changed it to three wires, the internal winding structure of the motor was unbalanced and the current of phase C was too high.
We suggest that you restore the internal wiring and capacitors of the single-phase motor to the original, and then you only need to connect the 2 wires of the single-phase motor to U,W of the VFD output terminal.
Please reset the parameters according to the parameter setting instructions of the attached single-phase motor, and test again.
Hope my explanation is able to assist you. Please feel free to let us know if you have any further questions.
Question about GK3000-1S0037
5
Cosmin
Avatar
2/21/2024 8:22 PM
I have two of these drives and I'm trying to run a three phase motor. Will it work or this can only do single phase in and single phase out? Thank you much.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can output 3 phases. If the process meets other problems you can contact our after-sales: support@ato.com.
PREGUNTA
5
ELLIOT
Avatar
6/25/2024 8:22 AM
ESTE VARIADOR DE FRECUENCIA SIRVE PARA MOTOR HERMETICOS DE COMPRESOR DE REFRIGERACION
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

1 hp (0.75 kW) VFD, Single Phase Input & Output

GK3000-1S0007
$195.82
Affordable 1 hp VFD, 1 phase for single phase AC induction motor, 220V - 240V 7 amps, manufacturer direct sale.

3 hp (2.2 kW) VFD, Single Phase Input & Output

GK3000-1S0022
$379.23
Cheap 3 hp VFD, 1 phase for single phase AC induction motor, good variable speed performance, 220V - 240V 17 amps, manufacturer direct sale.

7.5 hp (5.5 kW) VFD, Single Phase Input & Output

GK3000-1S0055
$996.85
Favorable price 7.5 hp VFD, 1 phase for single phase AC induction motor, high variable speed performance, 220V - 240V 32 amps, manufacturer direct sale.

2 hp (1.5kW) 220V Single Phase AC Induction Motor

ATO-SPIM-1500
$519.69
Cheap 2 hp single phase motor with 1.5kW, 1500rpm/3000rpm speed. It is an asynchronous motor. 200V/110V/230V/240V AC works at 50/60 Hz frequency. 2 hp 1 phase motor price is low. It has a start capacitor and run capacitor to provide zero starting torque during operation. The single phase induction motor is easy to repair and maintain, used for drills, air conditioners, compressors, pumps, cranes, garage door opening and closing systems.

4 hp (3kW) 220V Single Phase AC Induction Motor

ATO-SPIM-3000
$927.31
Hot selling 4 hp single phase motor with a start capacitor and run capacitor. 220V/110V/230V/240V is available. 1500rpm/3000rpm for selection. 3kW ac single phase induction motor works at 50/60 Hz, and provides zero starting torque at rest, used for drills, air conditioners, compressors, pumps, cranes, garage door opening and closing systems.