5 hp variable frequency drive, 4 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.
Specification:
| Basics | Model | GK3000-1S0037 |
| Capacity | 5 hp (4 kW) | |
| Shipping weight | 8 kg | |
| Dimension (H*W*D) | 330*200*200 mm | |
| I/O Feature | Rated current | 25 A |
| Input voltage | single phase AC 220V±15% | |
| Input frequency | 47~63Hz | |
| Output voltage | 0~rated input voltage | |
| Output frequency | 0~1000Hz | |
| Over load capacity | 150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s | |
| Control Features | Control mode | V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC) |
| Operation command mode | Keypad control, Terminal control, Serial communication control | |
| Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes. | |
| Start frequency | 0.40Hz~20.00Hz | |
| Speed adjustment range | 1:50 | |
| Carrier frequency | 1.0-16.0kHz, automatically adjusted according to temperature and load characteristics | |
| Frequency accuracy | Digital setting: 0.01Hz Analog setting: Maximum frequency * 0.05% | |
| Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0% | |
| V/f curve | Three types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square) | |
| Acceleration/deceleration mode | Straight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s | |
| Jog operation | Jog operation frequency: 0.0Hz~maximum frequency Jog acceleration/deceleration time: 0.1s~3600.0s | |
| Simple PLC & multi-step speed operation | It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. | |
| Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | |
| Automatic voltage regulation | Keep output voltage constant automatically when input voltage fluctuating | |
| Control Function | Common DC bus | Common DC bus for several VFDs, energy balanced automatically |
| Torque control | Torque control without PG | |
| Torque limit | "Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process | |
| Wobble frequency control | Multiple triangular-wave frequency control, special for textile | |
| Timing/length/counting control | Timing/length/counting control function | |
| Over-voltage & over-current stall control | Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping | |
| Fault protection function | Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function | |
| Input/output terminals | Input terminals | Programmable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI: AI1: 0~10V or 0/4~20mA A12: 0~10V or 0/4~20mA |
| Output terminals | 1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output) 2 relay output 2 analog output: 0/4~20mA or 0~10V | |
| Communication terminals | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |
| Human machine interface | LED display | Display frequency setting, output frequency, output voltage, output current, etc. |
| Multifunction key | QUICK/JOG key, can be used as multifunction key | |
| Environment | Ambient temperature | -10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃). |
| Humidity | 90%RH or less (non-condensing) | |
| Altitude | ≤1000M: Output rated power, >1000M: Output derated | |
| Storage temperature | -20℃~60℃ |
Note:
- The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
- ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
- Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
- If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.
Details

Tips: Six attentions of installing VFD in automatic control system
- For the frequency given signal should be used as far as possible 4-20mA international standard signal. Should make sure the signal line shield ground, to avoid the interference signal into the VFD. The production site has an interference signal, the interference signal will affect the stability of the control, so need to use input filter, and set its range to be 0.00-5.00s. If using VFD built-in PID function should use the feedback filter to increase the control stability of the built-in PID, the setting range is 0.0-60s. However, it should be noted that the filter time is set too long, the control is stable, but the system response is worse; the filter time is set too short, the system response is fast, but the control is unstable. So it should be based on the actual scene to make adjustments.
- To set the corresponding manual, automatic switching operating function. Optional manual, automatic, forced manual functions of manual operator. If necessary, could also consider the redundant operation function of the current and voltage setting, that is, the VFD frequency setting signal use current setting in normal, using voltage setting in abnormal manual operation. That is, add a potentiometer for setting g the VFD frequency, so the VFD frequency reference signal has two types, current signal and voltage signal. Because there are two types of frequency setting signals input in the VFD, increasing its redundancy degree.
- Must set the "overhaul switch", that is, set the "on-site overhaul switch" next to the operating equipment, when switch it to the "overhaul" position, equal to cut off the VFD running signal circuit. If someone misuse, the equipment can't run, to ensure that the safety of mechanical equipment maintainer.
- Make full use of the VFD input and output control terminals function, to carry out some alarm and interlock function, to reduce wiring and improve reliability.
- For single or simple control system, can take full advantage of the VFD built-in PID control function to reduce the control system equipments and reduce investment.
- Some VFD have input terminals R0, T0 of control power. So should connect control power to VFD R0, T0 side in front of the main power supply. So that the VFD still has a display function after the trip, in order to analyze the cause of the malfunction and take countermeasures.
Product reviews
Dominican Republic representative
Oscar
4/27/2018 12:36 AM
Do you have a representative in the Dominican Republic where I can purchase this 5hp VFD for single-phase motor use?
Was this review helpful? (0/0)
Good 5hp single phase VFD
Irene
4/20/2021 9:01 PM
For your 5hp single phase frequncy drive, does this keep the motor in it’s torque capability at low speed?
Was this review helpful? (0/0)
Good single phase VFD
Agrawal
6/3/2021 12:33 AM
Do you offer external potentiometer for external speed controls for your single phase drive?
Was this review helpful? (0/0)
My question about single VFD
Rizzo
10/31/2021 8:54 PM
What communications can your 1-phase drive handle? Analog input? Can it be directly communicated with by most PLCs?
Was this review helpful? (0/0)
I am interested in your single phase VFD
Palli
1/4/2022 12:27 AM
I am interested in the single phase output drives. Can I operate more than one fan motor on one drive?
Was this review helpful? (0/0)
Questions about 1-phase VFD
Patty
1/9/2022 8:41 PM
Do I unhook the start/run capacitors when connecting your 1-phase VFD to my 1-phase motor?
Was this review helpful? (0/0)
Just want to be absolutely clear before wiring everything up.
Randolph
7/27/2022 1:48 AM
Keep the R, S, and T terminals wired how it originally came, got it. And to confirm, the green wire going internally into the VFD IS grounded? So no need to attach anything to the E ground terminal? For the green and red wires, am I correct in saying you've attached the green wire to the white wire coming from the power supply cable, and the red wire to a black wire? Then these 2 wires have a 2 prong plug attached that goes into a wall outlet? And what's the green wire resting on the side of the VFD do?
Was this review helpful? (0/0)
Questions about 5HP VFD
Jaeden
3/3/2023 12:18 AM
Is the internal fan on the 5HP VFD supposed to run all the time the pump motor is running? Thank you.
Was this review helpful? (0/0)
Do you have electrical plug wiring picture of VFD?
ronnie
6/6/2023 2:48 AM
I have one question. We received the pump and the VFD.
I checked in the lab that we have the electrical plug NEMA 6-30, 208VAC, 30A single phase, with three wire.
As per the instruction manual to wire the VFD on 220V single phase, the picture (page 30) showed connection for only two wires.
Do you have the wire schematic to wire on the electrical plug NEMA 6-30, 208VAC, 30A single phase? I appreciate if you can help.
In advance, thank you for your time and help.
I checked in the lab that we have the electrical plug NEMA 6-30, 208VAC, 30A single phase, with three wire.
As per the instruction manual to wire the VFD on 220V single phase, the picture (page 30) showed connection for only two wires.
Do you have the wire schematic to wire on the electrical plug NEMA 6-30, 208VAC, 30A single phase? I appreciate if you can help.
In advance, thank you for your time and help.
Was this review helpful? (0/0)
Single phase VFD diagram
blanche
6/7/2023 1:00 AM
We are currently using this wearing diagram. With u we are at 6.75 amps with v we are at 22 amps and with w we are at 35 amps, which is too many amps.
Was this review helpful? (0/0)
Question about GK3000-1S0037
Cosmin
2/21/2024 8:22 PM
I have two of these drives and I'm trying to run a three phase motor. Will it work or this can only do single phase in and single phase out? Thank you much.
Was this review helpful? (0/0)
PREGUNTA
ELLIOT
6/25/2024 8:22 AM
ESTE VARIADOR DE FRECUENCIA SIRVE PARA MOTOR HERMETICOS DE COMPRESOR DE REFRIGERACION
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
1 hp (0.75 kW) VFD, Single Phase Input & Output
GK3000-1S0007
$195.82
Affordable 1 hp VFD, 1 phase for single phase AC induction motor, 220V - 240V 7 amps, manufacturer direct sale.
3 hp (2.2 kW) VFD, Single Phase Input & Output
GK3000-1S0022
$379.23
Cheap 3 hp VFD, 1 phase for single phase AC induction motor, good variable speed performance, 220V - 240V 17 amps, manufacturer direct sale.
7.5 hp (5.5 kW) VFD, Single Phase Input & Output
GK3000-1S0055
$996.85
Favorable price 7.5 hp VFD, 1 phase for single phase AC induction motor, high variable speed performance, 220V - 240V 32 amps, manufacturer direct sale.
2 hp (1.5kW) 220V Single Phase AC Induction Motor
ATO-SPIM-1500
$519.69
Cheap 2 hp single phase motor with 1.5kW, 1500rpm/3000rpm speed. It is an asynchronous motor. 200V/110V/230V/240V AC works at 50/60 Hz frequency. 2 hp 1 phase motor price is low. It has a start capacitor and run capacitor to provide zero starting torque during operation. The single phase induction motor is easy to repair and maintain, used for drills, air conditioners, compressors, pumps, cranes, garage door opening and closing systems.
4 hp (3kW) 220V Single Phase AC Induction Motor
ATO-SPIM-3000
$927.31
Hot selling 4 hp single phase motor with a start capacitor and run capacitor. 220V/110V/230V/240V is available. 1500rpm/3000rpm for selection. 3kW ac single phase induction motor works at 50/60 Hz, and provides zero starting torque at rest, used for drills, air conditioners, compressors, pumps, cranes, garage door opening and closing systems.