500VA 110V 60Hz to 220V 50Hz frequency converter with built-in step up transformer, also can change 220V 50Hz to 110V 60Hz power, output variable-frequency and variable-voltage for global appliance.
Specification:
| Model | HZ-60-500W | |
| Capacity | 500 VA | |
| Dimension | 420 (D)*330 (W)*180 (H) mm | |
| Weight | 40 kg | |
| Input | Voltage | 1 Phase 2 Wire: 110V, 120V, 220V, 230V, 240V ± 10% (Option *) |
| Frequency | 50 Hz, 60 Hz | |
| Output | Voltage, current | 120V Setting (Low grade): 0-150V, 4.2A |
| 240V Setting 0-300V (High grade): 0-300V, 2.1A | ||
| Load stabilization Rate | ≤±1% | |
| Frequency | 50Hz, 60Hz up to 400Hz adjustable Note: -When the output is 400Hz, the load capacity can only reach 50% of the rated capacity. -When the output is ≤120Hz, the load capacity can reach 100% of the rated value. -You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option. | |
| Frequency Stability | ≤±0.01% | |
| Harmonic Distortion | Pure Sine Wave ≤2% | |
| Frequency meter | 4 digit, digital frequency meter, resolution 0.1Hz/Step | |
| Voltmeter | 4 digit, digital voltage meter, resolution 0.1V | |
| Ammeter | 4 digit, digital ammeter, resolution 0.1A | |
| Watt meter | 4 digit, digital Watt meter, resolution 0.1W | |
| Protection | With overload, short circuit, over temperature | |
| Instantaneous power failure protection and alarm device | ||
| Working Environment | Temperature | 0 - 40 deg.℃ |
| Humidity | 0 - 90% (Non condensation) | |
| Warranty | 18 months | |
Features and Safe Usage Guide
Here is a video that shows you the main features of ATO single phase frequency converter and how you can use it to effectively and safely power electric equipment.
Tips: Why is the power supply 50Hz/60Hz, neither higher nor lower?
The frequency is related to the structure and material of the generator, motor and transformer. The synchronous speed of the bipolar generator in 50Hz is 3000rpm. However, if the frequency reaches 100Hz, the revolving speed will be 6000rpm. Such a high speed will cause many problems of generator manufacturing. In addition, in terms of application, too high frequency increases reactance and electromagnetic loss, intensifies idle work quantity. Moreover, if a relatively low frequency, such as 30Hz is used, the transformation efficiency is low, which will not be beneficial to the transformation and communication of the AC current.
The discrepancy of the power grid frequency depends on different calculation habits. The America starts early in large-scale electricity generation. The calculation tool used at that time is mainly the British (duodecimal number system) sliding scale. For better calculation, 60Hz is used. All relatively late power grids adopt decimal data, so 50Hz is more convenient.
INPUT: 115VAC or 220VAC 60Hz
OUTPUT: 3 phase, each leg 115V, 5A, 400Hz
Do you have an option to configure the input to accept either 115VAC or 220VAC?
If possible, I would like to drive control panels we make for Europe which would need 400 VAC 3 phase with Neutral.
Depending on what is driven, I would need 5 kW to 30 kW.
It looks like you have some products that will do at least some of these apps. Please let me know your suggestions.
I have set the frequency converter for 230V 50Hz. Once I start the load (turn the lamp on), the output current rises to 0.7~0.8A and then it trips and begins beeping until it is reset. Neither of the two fuses on the back are blown. I have tried increasing the voltage to 240V, as well as trying both output plugs on the front, with the same results.
It starts outputting power for a moment, then trips, followed by continuous beeping until reset. I know it is not the lamp itself, because we have another frequency converter that it works perfectly with. The only difference is the input voltage, our old model is 220V and our new one is 120V.
Do you have any suggestions of things to try, or could this unit be defective?
Just to confirm my process. With voltage set to 230v and frequency set to 50Hz (per the lamp), I follow the steps in this order. I have tried plugging the lamp into both output receptacles also.
1. GoHz Input ON
2. GoHz Power ON
3. GoHz Output ON
4. Honle lamp power ON
We will order the capacitors to install. Can you provide instructions for where they should be soldered onto the circuit board?
Do any of this troubleshooting steps void our units warranty?
To avoid the risk of damage, we have decided to stop further attempts before making the situation worse. As of right now, there is no change to the functionality of the unit, the circuits are intact as they were prior to our soldering attempts.
We need to return this unit to you for professional diagnosis and warranty repair, or get a replacement unit shipped to us that is capable of performing as advertised.
This model should be capable of running the lamp we have, which is why we selected it. It does not work as received, so we need to get a replacement.
Please let us know what is the most expeditious solution, as we need to use this tool very soon.