2 kVA solid state frequency converter (AC power supply), converting 60Hz to 50Hz, also changing 110V/120V to 220V/230V/240V, reliable power frequency changer with pure sine wave output.
Specification:
| Model | HZ-50-1102 (Cabinet Type), HZ-60-1102 (Benchtop Type) | |
| Capacity | 2 kVA | |
| Dimension | Benchtop Design | 590 (D)*490 (W)*230 (H) mm |
| Cabinet Design | 550 (D)*400 (W)*670 (H) mm | |
| Weight | Benchtop Design | 49 kg |
| Cabinet Design | 60 kg | |
| Input | Voltage | 1 Phase 2 Wire: 110V, 120V, 220V, 230V, 240V ± 10% (Option *) |
| Frequency | 50 Hz, 60 Hz | |
| Output | Voltage, current | 110V Setting (Low grade): 0-150V, 16.8A |
| 220V Setting 0-300V (High grade): 0-300V, 8.4A | ||
| Load stabilization Rate | ≤±1% | |
| Frequency | 50Hz, 60Hz up to 400Hz adjustable Note: -When the output is 400Hz, the load capacity can only reach 50% of the rated capacity. -When the output is ≤120Hz, the load capacity can reach 100% of the rated value. -You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option. | |
| Frequency Stability | ≤±0.01% | |
| Harmonic Distortion | Pure Sine Wave ≤2% | |
| Frequency meter | 4 digit, digital frequency meter, resolution 0.1Hz/Step | |
| Voltmeter | 4 digit, digital voltage meter, resolution 0.1V | |
| Ammeter | 4 digit, digital ammeter, resolution 0.1A | |
| Watt meter | 4 digit, digital Watt meter, resolution 0.1W | |
| Protection | With overload, short circuit, over temperature | |
| Instantaneous power failure protection and alarm device | ||
| Working Environment | Temperature | 0 - 40 deg.℃ |
| Humidity | 0 - 90% (Non condensation) | |
| Warranty | 18 months | |
Features and Safe Usage Guide
Here is a video that shows you the main features of ATO single phase frequency converter and how you can use it to effectively and safely power electric equipment.
Tips: Can the Variable Frequency Drive be used as the Frequency Converter?
Question: Can the VFD be used as the AC Power supply?
Answer: No. Because in practical application, the main application of the VFD is for the speed regulation of the motor. Moreover, it can only be equipped with one motor. Therefore, the variable-speed drive can not be used as the frequency converter. In addition, the AC frequency converter is exclusively designed and manufactured for import and export equipment, converts a basic fixed-frequency, fixed voltage sine-wave power to a variable-frequency, variable-voltage output, conforms to the power supply system of Europe and America. Thus can be used as the power supply of the import electricity equipment and production line, or the test power source of the import and export electrical product.
1) 5 kVA single phase 230V 50Hz to 110V 60Hz converter.
2) 10 kVA pure sine wave frequency converter. What do you recommend?
2. Output: 230V 1Ø 50Hz (European); though it would be nice to have the flexibility of testing standard USA split phase equipment in the future if possible.
3. Load will be various equipment associated with our hydro turbines-control panels, actuators, pumps. The pumps will have motors which will likely drive the converter selection. For this 15kVA unit, does the inrush current of the motor have to be below 62.5A or can it accommodate a temporary spike that is not listed here?
Input: 380V/50Hz/3-Phase
Output: 460V/60Hz/3-Phase
Capacity: 150 KVA. What do you recommend?
Our system requires 76 amps of 480V/3 phase/60 Hz.
Our system has (2) motors, one is 29 amps and the other is 35 amps, both are 480V/3 phase and both are controlled by soft starters. The rest of the load is a small conveyor motor of 5 amps and the control system with a PLC of 2 amps powered by a 480V x 24VDC power supply. No transformers or capacitors are being used on this system.