Features
- Universal AC input/Full range
- Protections: short circuit, overload and overvoltage
- Cooling by free air convection
- Installed on DIN rail TS-35/7.5 or 15
- Isolation class Ⅱ
- LED indicator for power on
- 100% full load burn-in test
Specification
| Model | ATO-DR-30-24 | |
| Output | DC Voltage | 24V |
| Rated Current | 1.5A | |
| Current Range | 0 ~ 1.5A | |
| Rated Power | 36W | |
| Ripple & Noise (Max.)(Note 2) | 150mVp-p | |
| Voltage Adjust Range | 21.6 ~ 26.4V | |
| Voltage Tolerance (Note 3) | ±1.0% | |
| Line Regulation | ±1.0% | |
| Load Regulation | ±1.0% | |
| Setup, Rise, Holdup Time | 100ms, 30ms, 100ms/230V AC 100ms, 30ms, 21ms/115V AC | |
| Input | Voltage Range | 85 ~ 264V AC or 120 ~ 370V DC |
| Frequency Range | 47~63Hz | |
| Efficiency (Typ.) | 83% | |
| AC Current (Typ.) | 0.88A/115V AC 0.48A/230V AC | |
| Inrush Current (Typ.) | Cold start: 15A/115V AC 30A/230V AC | |
| Protection | Overload | 105~160% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. |
| Overvoltage | 27.6V ~ 32.4V Protection type: Shut down output voltage, re-power on to recover. | |
| Environment | Working Temperature | -20 ~ +60℃ |
| Working Humidity | 20~90% RH non-condensing | |
| Storage Temperature | -40~+85℃ | |
| Storage Humidity | 10~95% RH non-condensing | |
| Temperature Coefficient | ±0.03%/℃ (0~50℃) | |
| Vibration | 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes | |
| Safety & EMC (Note 4) | Safety Standards | UL60950-1, TUV EN60950-1 Approved; Design refer to EN50178 |
| Withstand Voltage | I/P-O/P: 3KVAC | |
| Isolation Resistance | I/P-O/P: 100M Ohms/500VDC/25℃/70% RH | |
| EMC Emission | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2, -3 | |
| EMC Immunity | Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A | |
| Others | MTBF | ≥441.5K hrs MIN. MIL-HDBK-217F (25℃) |
| Dimension | 78*93*56mm (W*H*D) | |
| Weight | 0.27kg | |
| Note | 1. All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance includes set up tolerance, line regulation and load regulation. 4. The switching power supply is considered a component which will be installed into final equipment. Please make sure that the final equipment still meets EMC directives. | |
Dimensions (Unit: mm)

Details

Tips: Structure and functions of switching power supply (SMPS)
Switching power supply is composed of input power grid filter, input rectifier and filter, inverter, output rectifier and filter, control circuit, and protective circuit. Functions of each component are shown below:
- Input power grid filter: the filter is used to eliminate noise generated by start of electric motor, switches of devices, and thunder strike. At the same time, it is also used to prevent high-frequency noise generated by switching power supply from spreading into power grid.
- Input rectifier and filter: rectify and filter input voltage of power grid and provide Dc voltage for convertor.
- Invertor: invertor is a key part of switching power supply. It converts DC voltage to high-frequency AC voltage. In addition, it also isolates output part from input power grid.
- Output rectifier and filter: output rectifier and filter convert high-frequency AC voltage output by convertor to DC voltage through rectification and filtering. At the same time, it could alleviate the influence of high-frequency noise on load.
- Control circuit: control circuit detects output DC voltage to make a comparison with benchmark voltage and process with amplification to modulate pulse width of oscillator, control transformer and regulate voltage.
- Protective circuit: when switching power supply is bothered with overvoltage, overcurrent, or short circuit, the protective circuit will cut off power to protect load and the switching power supply.
Only registered users can write reviews
Customers who bought this item also bought
24V DC 8.3A 200W Switching Power Supply
ATO-SMPS-200-24
$67.58
Low price switching power supply transforms the full range of AC input to a stable DC voltage of 24V at the rated power 200W and rated current 8.3A, high efficiency and high reliability SMPS ideal for LED lights, printers, computers, monitoring cameras, industrial control, etc.
6 Digit Display Controller for Load Cells
ATO-DPM-DY800
$327.09
6 digit display controller can be used with load cells, force sensors and weighing sensors, 4-20mA or 0-10V transmitting signal output. This digital panel meter can display gross, net, peak and valley value alternately. Software with RS485 communication cable allows you to log the data on a PC.
Tension and Compression Load Cell, Threaded Inline, 1kN/5kN to 20kN
ATO-LC-107
$176.89
Buy affordable tension and compression load cell, threaded inline, support 0-20kN measuring range and repeatability of 0.5% F.S. with 350/700Ω impedance and 10kHz response frequency. The load cells are designed with a stainless steel body for durability, and can withstand an operating voltage of 5-15 V.
AC Current Sensor, AC 200A/400A/600A/800A
ATO-CUS-AC800
$88.25
AC current sensor adopts electromagnetic isolation principle, small size, light weight, low price, fast response, high accuracy, good stability, 35mm/45mm/55mm hole diameter, and screws fixed installation. AC current sensor is widely used for AC current measurement of various occasions, especially for sine-wave ac current with power frequency 50Hz.
Auto Range Multimeter, True RMS, 1000V/20A DC
ATO-MLT-19B
$94.26
Low price smart digital multimeter for sale online. It is a multimeter tester designed for voltage/resistance/capacitance/resistance measurement. 1000V 20A auto range multimeter desired for beginner, with 5999 max display, diode testing, triode testing, NCV test, true RMS, data hold, low battery indication, overload protection, etc.