Tension and Compression Load Cell, Threaded Inline, 1kN/5kN to 20kN

$176.89
Buy affordable tension and compression load cell, threaded inline, support 0-20kN measuring range and repeatability of 0.5% F.S. with 350/700Ω impedance and 10kHz response frequency. The load cells are designed with a stainless steel body for durability, and can withstand an operating voltage of 5-15 V.
SKU: ATO-LC-107
*
*
*
Free Shipping
Delivery date: 6-12 days

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Reliable and durable threaded inline tension and compression load cell. It can be selected from 0.5KN/1KN/2KN/3KN/5KN/10KN/20KN and is available at an affordable price. With a rated output of 1.5-2.0mV/V and a zero balance of ±2% F.S., this load cell ensures high accuracy and performance. The tensile and compression load cell can be used in a variety of fields such as automotive press fitting, automated assembly, 3C product testing, medical testing, and other applications.

Specification

ModelATO-DYMH-107
Capacity0.5KN/1KN/2KN/3KN/5KN/10KN/20KN (optional)
Matched TransmitterATO-LCTR-OA (Click it to the transmitter page)
Matched Display ControllerATO-DPM-DY800 (Click it to the controller page)
Rated Output1.5-2.0mV/V
Zero Balance±2%F.S.
Non-Linearity0.5%F.S.
Hysteresis0.5%F.S.
Repeatability0.5%F.S.
Creep0.05%F.S. (30min)
Temp Effect on Output0.05%F.S./10°C
Temp Effect on Zero0.05%F.S./10°C
Response Frequency10kHz
MaterialStainless steel
Impedance350/700Ω
Insulation≥5000MΩ/100VDC
Operating Voltage5-15V
Operating Temp Range-20°C~65°C
Safe Overload1.5
Maximum Overload2
Cable Specificationsφ5*2m
Cable Ultimate Pull10kg


Dimension (unit: mm)

Tension and compression load cell dimensions

Wiring Diagram

Tension and compression load cell wiring diagram

Force Diagram

Tension and compression load cell force diagram

Application

Tension and compression load cell application

Tips: How to ensure the measurement accuracy of the tension and compression load cell?

In order to ensure the accuracy of the tension and compression load cell, it is necessary to pay attention to the following points:

  • Correct Installation: Avoid additional stress interference and ensure that the load cell is subjected to uniform forces.
  • Periodic Calibration: Use standard weights or calibration equipment for periodic calibration.
  • Environmental Control: Avoid temperature changes, excessive humidity or electromagnetic interference affecting sensor performance.
  • Reasonable Range of Use: To avoid overloading or excessive impact force, so as not to affect the life and accuracy of the load cell sensor.
Product reviews
Reliable threaded load cell
5
Avra
Avatar
9/1/2025 8:11 PM
I've been using this threaded tension and compression load cell in my automotive testing setup for a few months now, and it’s been rock solid. The build quality is fantastic—stainless steel construction really holds up under repeated use. The accuracy is impressive; the readings are consistent even with temperature shifts in the workshop. Installation was straightforward thanks to the threaded design. I'm very satisfied.
Was this review helpful? Yes No (0/0)
Wiring Location
5
Luboa
Avatar
11/20/2025 7:12 PM
Do you have a model where the data cable runs through the top/bottom? This ATO-LC-107 might work, but we need the data cable at the top/bottom, not the side, because the side connector doesn't meet our requirements.
Was this review helpful? Yes No (0/0)
ATO Responded
We can customize sensors according to your requirements, starting from 3 units. Could you describe your field usage and provide a sketch?
Sensitivity
4
Nautia
Avatar
9/18/2026 2:21 AM
I have an ATO-DYMH-107 unit that has already been calibrated, but I would like to verify something. What slope/gain range should I expect? The label states "Sensitivity: 1.1 mV/V."
Was this review helpful? Yes No (0/0)
ATO Responded
If the 1.1 mV/V sensitivity shown on the sensor's label is the value obtained from actual production testing, then it is normal; the 1.5–2.0 mV/V figure is merely a reference range.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Reliable and durable threaded inline tension and compression load cell. It can be selected from 0.5KN/1KN/2KN/3KN/5KN/10KN/20KN and is available at an affordable price. With a rated output of 1.5-2.0mV/V and a zero balance of ±2% F.S., this load cell ensures high accuracy and performance. The tensile and compression load cell can be used in a variety of fields such as automotive press fitting, automated assembly, 3C product testing, medical testing, and other applications.

Specification

ModelATO-DYMH-107
Capacity0.5KN/1KN/2KN/3KN/5KN/10KN/20KN (optional)
Matched TransmitterATO-LCTR-OA (Click it to the transmitter page)
Matched Display ControllerATO-DPM-DY800 (Click it to the controller page)
Rated Output1.5-2.0mV/V
Zero Balance±2%F.S.
Non-Linearity0.5%F.S.
Hysteresis0.5%F.S.
Repeatability0.5%F.S.
Creep0.05%F.S. (30min)
Temp Effect on Output0.05%F.S./10°C
Temp Effect on Zero0.05%F.S./10°C
Response Frequency10kHz
MaterialStainless steel
Impedance350/700Ω
Insulation≥5000MΩ/100VDC
Operating Voltage5-15V
Operating Temp Range-20°C~65°C
Safe Overload1.5
Maximum Overload2
Cable Specificationsφ5*2m
Cable Ultimate Pull10kg


Dimension (unit: mm)

Tension and compression load cell dimensions

Wiring Diagram

Tension and compression load cell wiring diagram

Force Diagram

Tension and compression load cell force diagram

Application

Tension and compression load cell application

Tips: How to ensure the measurement accuracy of the tension and compression load cell?

In order to ensure the accuracy of the tension and compression load cell, it is necessary to pay attention to the following points:

  • Correct Installation: Avoid additional stress interference and ensure that the load cell is subjected to uniform forces.
  • Periodic Calibration: Use standard weights or calibration equipment for periodic calibration.
  • Environmental Control: Avoid temperature changes, excessive humidity or electromagnetic interference affecting sensor performance.
  • Reasonable Range of Use: To avoid overloading or excessive impact force, so as not to affect the life and accuracy of the load cell sensor.
Product reviews
Reliable threaded load cell
5
Avra
Avatar
9/1/2025 8:11 PM
I've been using this threaded tension and compression load cell in my automotive testing setup for a few months now, and it’s been rock solid. The build quality is fantastic—stainless steel construction really holds up under repeated use. The accuracy is impressive; the readings are consistent even with temperature shifts in the workshop. Installation was straightforward thanks to the threaded design. I'm very satisfied.
Was this review helpful? Yes No (0/0)
Wiring Location
5
Luboa
Avatar
11/20/2025 7:12 PM
Do you have a model where the data cable runs through the top/bottom? This ATO-LC-107 might work, but we need the data cable at the top/bottom, not the side, because the side connector doesn't meet our requirements.
Was this review helpful? Yes No (0/0)
ATO Responded
We can customize sensors according to your requirements, starting from 3 units. Could you describe your field usage and provide a sketch?
Sensitivity
4
Nautia
Avatar
9/18/2026 2:21 AM
I have an ATO-DYMH-107 unit that has already been calibrated, but I would like to verify something. What slope/gain range should I expect? The label states "Sensitivity: 1.1 mV/V."
Was this review helpful? Yes No (0/0)
ATO Responded
If the 1.1 mV/V sensitivity shown on the sensor's label is the value obtained from actual production testing, then it is normal; the 1.5–2.0 mV/V figure is merely a reference range.
Only registered users can write reviews
Customers who bought this item also bought

24V DC 1.5A 36W Switching Power Supply

ATO-SMPS-30-24
$68.46
Compact size 24V DC switching power supply is installed in DIN rail with 36W rated power and 1.5A rated current, low cost and high quality SMPS, with short circuit, overload and overvoltage protection, ideal power supply for office, home and industrial equipment.

6 Digit Display Controller for Load Cells

ATO-DPM-DY800
$327.09
6 digit display controller can be used with load cells, force sensors and weighing sensors, 4-20mA or 0-10V transmitting signal output. This digital panel meter can display gross, net, peak and valley value alternately. Software with RS485 communication cable allows you to log the data on a PC.

24V DC 4.5A 100W Switching Power Supply

ATO-SMPS-100-24
$58.15
Low price 24V DC switching power supply has universal AC input voltage (selected by a switch), 4.5A rated current and 108W rated power, cooling by free air convection, short circuit and overload protection, ideal SMPS power supply for all kinds of applications.

Load Cell Transmitter, Output 0-5V/0-10V/4-20mA

ATO-LCTR-OA
$81.27