10A 3-phase EMI Line Filter, 2 Stage

$117.92
10A 2-stage EMI line filter, 3-phase 3-wire or 3-phase 4-wire, rated voltage 250/440V AC 50/60Hz, excellent performance of EMI suppression in the industrial equipment, compact size, stud connection, low price and high reliability.
SKU: ATO-EMI-2010
*
Free Shipping
Delivery date: 8-12 days

10 Amp dual-stage EMI power line filter is suitable for 3-phase 3-wire or 3-phase 4-wire AC power system, and it is widely used in various electrical equipment, including printing equipment, packaging equipment, textile equipment, industrial air conditioners, UPS, motors, servo systems, communication equipment, variable frequency device, electric drives, etc.

Specification

ModelATO-MT720-10ATO-MT820-10
Configuration2 Stage2 Stage
Rated Current @ 40℃10A10A
Rated Voltage250/440V AC440V AC
Operating Frequency50/60Hz50/60Hz
PhaseThree Phase Three WireThree Phase Four Wire
Leakage Current (250VAC 50Hz @ 20℃)≤4.0mA≤2.0mA
Filter Range150KHz-30MHz150KHz-30MHz
Hipot Rating (one minute)Line to Line: 2250VDC 3S
Line to Ground: 2700VDC 3S
Line to Line: 2250V DC
Line to Neutral: 1760V DC
Line to Ground: 2700V DC
Climatic Category25/085/2125/085/21
Working Temperature-25°C~+85°C-25°C~+85°C
Output TermainalThreaded studThreaded stud
Weight1kg1kg
DimensionSee belowSee below

Dimensions (Unit: mm)

  • 3-phase 3-wire line filter

10A 3-Phase 3-Wire 2-Stage Power Line Filter Dimension

  • 3-phase 4-wire line filter

10A 20A 3-Phase 4-Wire EMI Power Line Filter Dimension

Electrical Schematic

  • 3-phase 3-wire line filter

3-phase 3-Wire 2-stage Power Line Filter Electrical Schematic

  • 3-phase 4-wire line filter

10A 3-Phase 4-Wire EMI Power Line Filter Electrical Schematic

Tips: Passive filter versus active filter

Passive filter advantages are simple circuit, no need of DC power supply, and high reliability. It has its own disadvantages: signal inside pass band has energy consumption; load effect is obvious; it is easy to have electromagnetic induction when using electrical-induce element. When inductance(L) is large, filter dimension and weight is also large, not suitable in low frequency field.

Active filter advantages: signal inside pass band has no energy consumption, and also can be amplified; load effect is not obvious, and mutual effect is very small for multilevel linkage. Taking cascading method is easy to constitute high-stage filter, which is in small dimension, light weight, no need of magnetic shielding (due to no use of inductance element). It also has some disadvantages. Since it is limited by band width of active component in the range of pass band, it needs to be energized by DC power supply. Thus reliability is not as good as passive filter. It is not suitable in high-voltage, high-frequency, large-power occasions.

Single Phase and Three Phase EMI Power Line Filters

In this video, basic information and installation guidelines for single phase and three phase EMI power line filters are presented.

Product reviews
How to install a 10A three-phase EMI line filter?
5
Mckenney
Avatar
10/19/2021 12:05 AM
I bought this 10A three-phase EMI line filter for the first time. How do I install it?
Was this review helpful? Yes No (0/0)
ATO Responded
Only need four simple steps to complete the installation:
The first step: Fix.
Step 2: Grounding.
The third step: Phase line connection.
Step 4: Fasten the bolts.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

10 Amp dual-stage EMI power line filter is suitable for 3-phase 3-wire or 3-phase 4-wire AC power system, and it is widely used in various electrical equipment, including printing equipment, packaging equipment, textile equipment, industrial air conditioners, UPS, motors, servo systems, communication equipment, variable frequency device, electric drives, etc.

Specification

ModelATO-MT720-10ATO-MT820-10
Configuration2 Stage2 Stage
Rated Current @ 40℃10A10A
Rated Voltage250/440V AC440V AC
Operating Frequency50/60Hz50/60Hz
PhaseThree Phase Three WireThree Phase Four Wire
Leakage Current (250VAC 50Hz @ 20℃)≤4.0mA≤2.0mA
Filter Range150KHz-30MHz150KHz-30MHz
Hipot Rating (one minute)Line to Line: 2250VDC 3S
Line to Ground: 2700VDC 3S
Line to Line: 2250V DC
Line to Neutral: 1760V DC
Line to Ground: 2700V DC
Climatic Category25/085/2125/085/21
Working Temperature-25°C~+85°C-25°C~+85°C
Output TermainalThreaded studThreaded stud
Weight1kg1kg
DimensionSee belowSee below

Dimensions (Unit: mm)

  • 3-phase 3-wire line filter

10A 3-Phase 3-Wire 2-Stage Power Line Filter Dimension

  • 3-phase 4-wire line filter

10A 20A 3-Phase 4-Wire EMI Power Line Filter Dimension

Electrical Schematic

  • 3-phase 3-wire line filter

3-phase 3-Wire 2-stage Power Line Filter Electrical Schematic

  • 3-phase 4-wire line filter

10A 3-Phase 4-Wire EMI Power Line Filter Electrical Schematic

Tips: Passive filter versus active filter

Passive filter advantages are simple circuit, no need of DC power supply, and high reliability. It has its own disadvantages: signal inside pass band has energy consumption; load effect is obvious; it is easy to have electromagnetic induction when using electrical-induce element. When inductance(L) is large, filter dimension and weight is also large, not suitable in low frequency field.

Active filter advantages: signal inside pass band has no energy consumption, and also can be amplified; load effect is not obvious, and mutual effect is very small for multilevel linkage. Taking cascading method is easy to constitute high-stage filter, which is in small dimension, light weight, no need of magnetic shielding (due to no use of inductance element). It also has some disadvantages. Since it is limited by band width of active component in the range of pass band, it needs to be energized by DC power supply. Thus reliability is not as good as passive filter. It is not suitable in high-voltage, high-frequency, large-power occasions.

Product reviews
How to install a 10A three-phase EMI line filter?
5
Mckenney
Avatar
10/19/2021 12:05 AM
I bought this 10A three-phase EMI line filter for the first time. How do I install it?
Was this review helpful? Yes No (0/0)
ATO Responded
Only need four simple steps to complete the installation:
The first step: Fix.
Step 2: Grounding.
The third step: Phase line connection.
Step 4: Fasten the bolts.
Only registered users can write reviews
Customers who bought this item also bought

2 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

GK3000-CS0015
$345.77
2 hp variable frequency drive for sale, converts 1-phase 220v-240v AC input to 3-phase 380v/ 400v output. 1.5 kW VFD for AC motor control, 3.8 amps, wide speed adjustment range.

EMI Power Line Filter 10A, 3 phase

ATO-EMI-1010
$89.92
EMI power line filter, 3-phase 3-wire, single stage, rated current 10A, operating frequency 50/60Hz and voltage rating to 250V/440V AC, connected with threaded stud, excellenct attenuation performance and favorable price.

EMC Output Filter for VFD, 6A/20A/80A/150A/300A to 1000A

ATO-EMC-730T
$116.76
Good quality EMC output filter for sale, designed for VFD load side to reduce the common-mode noise, protect the load and extend service life, 3-phase VFD output filter with rated voltage 250/440VAC 50/60Hz, current rating from 6 Amps to 1000 Amps, threaded stud or quick connect, high performance yet favorable price.