EMI Power Line Filter 10A, 3 phase

$89.92
EMI power line filter, 3-phase 3-wire, single stage, rated current 10A, operating frequency 50/60Hz and voltage rating to 250V/440V AC, connected with threaded stud, excellenct attenuation performance and favorable price.
SKU: ATO-EMI-1010
Free Shipping
Delivery date: 8-12 days

10A EMI power line filter is easily mounted with screw, effective noise suppression, and provides effective shield for the power supplies like 3-phase motor drive, UPS, packaging equipment, textile equipment, industrial air conditioners, and other 3-phase 3-wire automatic equipment.

Specification

ModelATO-MT710-10
Filter TypeEMI
ConfigurationSingle Stage
Rated Current @ 40℃10A
Rated Voltage250/440V AC
Operating Frequency50/60Hz
PhaseThree Phase Three Wire
Leakage Current≤5mA @ 250V AC 50Hz 20℃
Filter Range150KHz-30MHz
Hipot Rating (one minute)Line to Line1450V DC
Line to Ground2250V DC
Climatic Category25/085/21
Working Temperature-25°C~+85°C
Output TermainalThreaded stud M4
Weight510g
DimensionSee below

Dimensions (Unit: mm)

10A 3-phase EMI Line Filter Dimension

Electrical Schematic

Three phase emi filter electrical schematic

Insertion Loss Table (in 50Ω system acccording to IEC/CISPR No.17)

6A 10A 20A 30A Power Line Filter Insertion Loss Table

40A 50A 100A EMI Line Filter Insertion Loss Table

Tips: How to use a filter to suppress EMI of switching power supply?

A filter is an effective measure to restrain interference, especially conducting interference and radiation interference for switching power supply EMI signal. Conducting interference signal in any power line could be expressed by differential mode and common mode signal. Differential mode interference will transmit between 2 wires, belonging to symmetrical interference; common mode interference transmits between wire and grounding (housing), belonging to non-symmetrical interference. Under normal condition, differential mode interference has small range, low frequency, and the caused interference is small. Common mode interference has large range, high frequency, able to generate radiation through wire, and the caused interference is large. Therefore, if you want to weaken conducting interference and control the EMI signal under the limit level which is stipulated by related EMC standard, the best way is to install EMI filter in switching power supply input and output circuit. Working frequency of switching power is about 10kHz~100kHz. Most of EMC standards specified that the limit value of conducting interference level is from 10 kHz. Referring to high frequency band EMI signal generating by switch power supply, only choose the EMI filter with decoupling circuit or simple network structure, and then you can get satisfied effect.

Single Phase and Three Phase EMI Power Line Filters

In this video, basic information and installation guidelines for single phase and three phase EMI power line filters are presented.

Product reviews
Outstanding EMI Power Line Filter
5
Bill
Avatar
3/21/2022 12:14 AM
This EMI power line filter meets my need and it works perfect. Everything is great. I have used it for 5 weeks and now I would like to recommend you to have one since it is a good deal and the price is reasonable.
Was this review helpful? Yes No (0/0)
If can be used for 220V 60Hz?
5
Beeyh
Avatar
8/1/2023 11:56 PM
I didn't check the voltaje when I made the purchase, could you help me to know if can be used for 220V 60Hz?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we confirm that it can be used for 3-phase 220V 60Hz and the maximum voltage reaches 400VAC. But please note: it can not connect the natural line N.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

10A EMI power line filter is easily mounted with screw, effective noise suppression, and provides effective shield for the power supplies like 3-phase motor drive, UPS, packaging equipment, textile equipment, industrial air conditioners, and other 3-phase 3-wire automatic equipment.

Specification

ModelATO-MT710-10
Filter TypeEMI
ConfigurationSingle Stage
Rated Current @ 40℃10A
Rated Voltage250/440V AC
Operating Frequency50/60Hz
PhaseThree Phase Three Wire
Leakage Current≤5mA @ 250V AC 50Hz 20℃
Filter Range150KHz-30MHz
Hipot Rating (one minute)Line to Line1450V DC
Line to Ground2250V DC
Climatic Category25/085/21
Working Temperature-25°C~+85°C
Output TermainalThreaded stud M4
Weight510g
DimensionSee below

Dimensions (Unit: mm)

10A 3-phase EMI Line Filter Dimension

Electrical Schematic

Three phase emi filter electrical schematic

Insertion Loss Table (in 50Ω system acccording to IEC/CISPR No.17)

6A 10A 20A 30A Power Line Filter Insertion Loss Table

40A 50A 100A EMI Line Filter Insertion Loss Table

Tips: How to use a filter to suppress EMI of switching power supply?

A filter is an effective measure to restrain interference, especially conducting interference and radiation interference for switching power supply EMI signal. Conducting interference signal in any power line could be expressed by differential mode and common mode signal. Differential mode interference will transmit between 2 wires, belonging to symmetrical interference; common mode interference transmits between wire and grounding (housing), belonging to non-symmetrical interference. Under normal condition, differential mode interference has small range, low frequency, and the caused interference is small. Common mode interference has large range, high frequency, able to generate radiation through wire, and the caused interference is large. Therefore, if you want to weaken conducting interference and control the EMI signal under the limit level which is stipulated by related EMC standard, the best way is to install EMI filter in switching power supply input and output circuit. Working frequency of switching power is about 10kHz~100kHz. Most of EMC standards specified that the limit value of conducting interference level is from 10 kHz. Referring to high frequency band EMI signal generating by switch power supply, only choose the EMI filter with decoupling circuit or simple network structure, and then you can get satisfied effect.

Product reviews
Outstanding EMI Power Line Filter
5
Bill
Avatar
3/21/2022 12:14 AM
This EMI power line filter meets my need and it works perfect. Everything is great. I have used it for 5 weeks and now I would like to recommend you to have one since it is a good deal and the price is reasonable.
Was this review helpful? Yes No (0/0)
If can be used for 220V 60Hz?
5
Beeyh
Avatar
8/1/2023 11:56 PM
I didn't check the voltaje when I made the purchase, could you help me to know if can be used for 220V 60Hz?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we confirm that it can be used for 3-phase 220V 60Hz and the maximum voltage reaches 400VAC. But please note: it can not connect the natural line N.
Only registered users can write reviews
Customers who bought this item also bought

10A 3-phase EMI Line Filter, 2 Stage

ATO-EMI-2010
$117.92
10A 2-stage EMI line filter, 3-phase 3-wire or 3-phase 4-wire, rated voltage 250/440V AC 50/60Hz, excellent performance of EMI suppression in the industrial equipment, compact size, stud connection, low price and high reliability.

EMC Output Filter for VFD, 6A/20A/80A/150A/300A to 1000A

ATO-EMC-730T
$116.76
Good quality EMC output filter for sale, designed for VFD load side to reduce the common-mode noise, protect the load and extend service life, 3-phase VFD output filter with rated voltage 250/440VAC 50/60Hz, current rating from 6 Amps to 1000 Amps, threaded stud or quick connect, high performance yet favorable price.