2 hp (1.5 kW) VFD at low cost, with 220 volt single phase input, 380 volt, 415 volt three phase output. This variable frequency converter controlled by V/F, sensorless vector control mode.
Specification:
| Basics | Model | GK3000-CS0015 |
| Capacity | 2 hp (1.5 kW) | |
| Shipping weight | 3 kg | |
| Dimension | 236*130*176 mm | |
| Installation size | 222*116 mm | |
| I/O Feature | Rated current | 3.8 A |
| Input voltage | 1 phase 220~240V AC | |
| Input frequency | 50Hz/ 60Hz | |
| Output voltage (Optional) | 3 phase AC 380V/ 400V/ 415V/ 440V/ 460V (Note: 440V, 460V output voltage only for the 1-phase 240V input VFD) | |
| Output frequency | 0Hz~1000Hz | |
| Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
| Control Feature | Control mode | V/F control; Sensorless vector control; |
| Communication | RS485 | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
| Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
| Humidity | 5%-95%, without condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
Tips: 1-phase 220V input to 3-phase 380V VFD functions
- The phase change function of single phase to three phase, the function of frequency conversion.
- With most of the functions of a general-purpose VFD, such as soft start function (reduce the starting current, reduce the impact on the power grid, can replace the soft starter), speed control function (0 to motor rated speed infinitely adjustable), terminal start-stop forward-reverse switching function (through an external switch to control the motor start, stop, forward and reverse, can replace the AC contactor), etc..
- With motor protection functions, over-current overload over-voltage over-heat short-circuit protection, etc., effectively extending the service life of the equipment.
1-phase 220 volt to 3-phase 380 volt VFD can solve the reality of the problem:
- Power supply voltage mismatch problem, that is, power supply 220V, equipment power 380V.
- The power supply phase mismatch problem, that is, the power supply 1-phase, equipment with electricity 3-phase.
- Power supply frequency mismatch, that is, the power supply 50Hz/60Hz, equipment with electricity 0-400Hz (arbitrary setting).
Product reviews
How to install 2 hp VFD?
Kelly
5/11/2021 8:48 PM
Is the 2hp VFD designed to be installed in an enclosure or can it be installed on the wall inside the electrical/mechanical room. If installed on the wall is there a cove plate for the electrical conduit to secure to etc?
Was this review helpful? (1/0)
I want to buy an ATO's VFD
Raybell
9/17/2021 7:50 PM
I just purchased the VFD.
Everything works, the motor spins based on the potentiometer speed controller.
My question is, is there any way to set/program so the motor automatically spins (based on the current potentiometer speed setting) when I power on the VFD?
I appreciate your support.
Everything works, the motor spins based on the potentiometer speed controller.
My question is, is there any way to set/program so the motor automatically spins (based on the current potentiometer speed setting) when I power on the VFD?
I appreciate your support.
Was this review helpful? (0/0)
Can our motor be connected to your VFD?
Stephens
12/15/2021 12:12 AM
The motor I have is an old wood shaper from the year 1941. The 3450 rpm motor is pulley to create 8500 at the working end of the cutting tool. I want to spin it to approx. 14,000 RPM, can I use your VFD?
Was this review helpful? (0/0)
Single to Three Phase VFD
Levis
2/5/2024 11:08 PM
I am not able to reverse my motor with the reverse button, when I press it no movement happens. But, if I change p0.04 to 1, it will reverse in the forward direction. Is there something I can change to be able to reverse?
Was this review helpful? (0/0)
I need some help
Jewel
11/25/2024 6:15 PM
I have an ATO GK3000 and I would like to control fan speed, single phase 240v motor. I have removed capacitors from a motor (Start and running) and followed programming from your manual, it works but create high frequency noise, on some speed vibrate and I'm sure get hot quicker than normally. Could you help me with this?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
10A 3-phase EMI Line Filter, 2 Stage
ATO-EMI-2010
$117.92
10A 2-stage EMI line filter, 3-phase 3-wire or 3-phase 4-wire, rated voltage 250/440V AC 50/60Hz, excellent performance of EMI suppression in the industrial equipment, compact size, stud connection, low price and high reliability.
10 hp VFD, 1-Phase 220V to 3-Phase 380V VFD
GK3000-CS0075G
$1,095.67
Affordable price 10 hp (7.5 kW) VFD, converts 220v/ 230v /240v 1 phase input to 380v/ 400v/ 415v 3 phase output, 17 amps, V/F and sensorless vector control.