80A 3-phase EMI Line Filter, 2 Stage

$285.62
80A 3-phase 3-wire EMI line filter, dual stage, rated voltage 250/440V AC 50/60Hz, threaded stud connection, excellent performance in differetial mode, best filter for printing equipment, servo system, UPS, etc.
SKU: ATO-EMI-2080
Free Shipping
Delivery date: 8-12 days

80A EMI power line filter in dual-stage configuration, is widely used in the printing equipment, packaging equipment, textile equipment, industrial air conditioners, UPS, motors, servo systems, communication equipment, variable frequency device, electric drives, etc.

Specification

ModelATO-MT720-80
Configuration2 Stage
Rated Current @ 40℃80A
Rated Voltage250/440V AC
Operating Frequency50/60Hz
PhaseThree Phase Three Wire
Leakage Current (250VAC 50Hz @ 20℃)≤6.0mA
Filter Range150KHz-30MHz
Hipot Rating (one minute)Line to Line: 2250V DC 3S
Line to Ground: 2700V DC 3S
Climatic Category25/085/21
Working Tempearte-25°C~+85°C
Output TermainalThreaded stud
Weight3.5kg
DimensionSee below

Dimensions (Unit: mm)

80A 3-phase EMI Line Filter Dimension

Electrical Schematic

3-phase 2-stage Power Line Filter Electrical Schematic

Tips: What is a low pass filter?

Low pass filter is an electrical filter device which only allows the signal lower than cut-off frequency to pass, and all the signal higher than cut-off frequency can’t pass. The performance of low pass filter in signal processing is similar to the rolling average performance in finance field. For different filter, the weakening degree of each frequency signal is different. Low pass filter has many types, of which, Butterworth, Chebyshev are often used.

Low pass filter principle is very simple, making use of capacitor to pass high frequency and prevent low frequency, and inductor for low frequency pass and high frequency stop. The principle of low pass filter is, for the cut-off high frequency, prevent it by capacitor absorbing and inductor blocking; for low frequency needed, make it pass via the characteristics of capacitor with high resistance and inductive with low resistance.

Single Phase and Three Phase EMI Power Line Filters

In this video, basic information and installation guidelines for single phase and three phase EMI power line filters are presented.

Product reviews
3-phase EMI line filter for long-term use
5
Elowen
Avatar
8/18/2025 9:35 PM
The 80A 3-phase EMI line filter works exactly as advertised.  After installing it on my servo system, the level of electrical noise dropped significantly, and the equipment now runs much more smoothly without unexpected interference.  The dual-stage design clearly provides excellent suppression across the specified 150kHz–30MHz range.  Build quality is solid, with sturdy threaded stud connections and a heavy-duty housing that feels reliable for long-term use.  I also tested it on a variable frequency drive, and the performance was equally impressive.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

80A EMI power line filter in dual-stage configuration, is widely used in the printing equipment, packaging equipment, textile equipment, industrial air conditioners, UPS, motors, servo systems, communication equipment, variable frequency device, electric drives, etc.

Specification

ModelATO-MT720-80
Configuration2 Stage
Rated Current @ 40℃80A
Rated Voltage250/440V AC
Operating Frequency50/60Hz
PhaseThree Phase Three Wire
Leakage Current (250VAC 50Hz @ 20℃)≤6.0mA
Filter Range150KHz-30MHz
Hipot Rating (one minute)Line to Line: 2250V DC 3S
Line to Ground: 2700V DC 3S
Climatic Category25/085/21
Working Tempearte-25°C~+85°C
Output TermainalThreaded stud
Weight3.5kg
DimensionSee below

Dimensions (Unit: mm)

80A 3-phase EMI Line Filter Dimension

Electrical Schematic

3-phase 2-stage Power Line Filter Electrical Schematic

Tips: What is a low pass filter?

Low pass filter is an electrical filter device which only allows the signal lower than cut-off frequency to pass, and all the signal higher than cut-off frequency can’t pass. The performance of low pass filter in signal processing is similar to the rolling average performance in finance field. For different filter, the weakening degree of each frequency signal is different. Low pass filter has many types, of which, Butterworth, Chebyshev are often used.

Low pass filter principle is very simple, making use of capacitor to pass high frequency and prevent low frequency, and inductor for low frequency pass and high frequency stop. The principle of low pass filter is, for the cut-off high frequency, prevent it by capacitor absorbing and inductor blocking; for low frequency needed, make it pass via the characteristics of capacitor with high resistance and inductive with low resistance.

Product reviews
3-phase EMI line filter for long-term use
5
Elowen
Avatar
8/18/2025 9:35 PM
The 80A 3-phase EMI line filter works exactly as advertised.  After installing it on my servo system, the level of electrical noise dropped significantly, and the equipment now runs much more smoothly without unexpected interference.  The dual-stage design clearly provides excellent suppression across the specified 150kHz–30MHz range.  Build quality is solid, with sturdy threaded stud connections and a heavy-duty housing that feels reliable for long-term use.  I also tested it on a variable frequency drive, and the performance was equally impressive.