Affordable price 3 hp (2.2 kW) VFD, features 220v/ 230v /240v single phase input, 380v three phase output. This frequency drive inverter built-in RS485 communication interface, easy to wire and operate.
Specification:
| Basics | Model | GK3000-CT0022 |
| Capacity | 3 hp (2.2 kW) | |
| Shipping weight | 5 kg | |
| Dimension | 247*159*179 mm | |
| Installation size | 148*235 mm | |
| I/O Feature | Rated current | 5.1 A |
| Input voltage | 1 phase 220~240V AC | |
| Input frequency | 50Hz/ 60Hz | |
| Output voltage (Optional) | 3 phase AC 380V/ 400V/ 415V/ 440V/ 460V (Note: 440V, 460V output voltage only for the 1-phase 240V input VFD) | |
| Output frequency | 0Hz~400Hz | |
| Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
| Control Feature | Control mode | V/F control; Sensorless vector control; |
| Communication | RS485 | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
| Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
| Humidity | 5%-95%, without condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
5 tips for using 1-phase 220V to 3-phase 380V VFD
- The power at the input of the variable frequency drive must be sufficient, otherwise the operation will jump under voltage fault can not be normal operation.
- Single phase 220v to three phase 380v VFD belongs to the boost circuit step-up, for the load side of the maximum for the light-load site below 30hp (22kW), in terms of selection, the light-load motor use a large level of VFD, heavy-load site use a large two-level VFD.
- 1-phase to 3-phase VFD can only be used for motor class inductive load, can not be used as other load power supply.
- The VFD is not suitable for the need to quickly start and stop the site, and the occasion of the bit energy load.
- Part of the equipment motor can be used by changing the motor connection three-phase 220V electricity (such as motor star connection state is three-phase 380V motor, can be changed to delta connection can use three-phase 220V, the specific can consult the motor manufacturer), at this time can buy ATO single-phase 220V to three-phase 220V VFD to solve the problem of phase change.
Product reviews
The best 3hp VFD
kipker
4/7/2021 7:06 PM
To run a 3hp 3ph motor of single phase do you need a 3 hp vfd or one that is overrated?
Was this review helpful? (0/0)
VFD related information
Eldon
9/21/2021 7:53 PM
Please, I bought an ATO VFD to reduce the speed of my electric motor to 1800rpm from 3450 rpm.
The manual that came with it says solar inverter. I tried to follow the steps in setting it up and I could get it to work.
Please, I would appreciate it if someone could create the time to take me through setting up this VFD / electric motor project.
Find attached photos showing the VFD and my electric motor.
The manual that came with it says solar inverter. I tried to follow the steps in setting it up and I could get it to work.
Please, I would appreciate it if someone could create the time to take me through setting up this VFD / electric motor project.
Find attached photos showing the VFD and my electric motor.
Was this review helpful? (0/0)
I have some questions
Luxia
12/10/2024 12:07 AM
At this time changing motors is not really a viable option. What setting could you recommend to allow a soft start ramp up over say 5s or so and then run the pump at full speed until required pressure is reached and then perform a soft shutdown from 100% down to say 50% over say 10s then sleep? That should eliminate the chances of running the motor at low speed for excessive periods of time.
Also, does it make any difference to use VI (voltage input) versus CI (current input) for the pressure signal. VI would make troubleshooting easier. What settings might we change for thus? With all the discrepancies between the manuals it is difficult to know which one to use. This is why I am asking you to suggest settings or tutorials. Is it advisable to use the dynamic self-learning with this configuration and if so what do I do after it reads -FUN-?
Also, does it make any difference to use VI (voltage input) versus CI (current input) for the pressure signal. VI would make troubleshooting easier. What settings might we change for thus? With all the discrepancies between the manuals it is difficult to know which one to use. This is why I am asking you to suggest settings or tutorials. Is it advisable to use the dynamic self-learning with this configuration and if so what do I do after it reads -FUN-?
Was this review helpful? (0/0)
No transducer input detected on CI
Tiyan
2/21/2025 12:03 AM
The GK3000 does not seem to be detecting the transducer input on CI. The transducer is providing a voltage signal and a proportional < 20mA signal when connected to COM via a 120 ohm resistor. None of the feedback monitors (b0.10 and b0.47) will report any change at all. Both report between 0 and .002 and .0008, respectively. We would prefer that the transducer feedback be measured in volts (instead of mA) to make the troubleshooting easier, but it is pointless as the VFD does not seem to be receiving any feedback from the transducer.
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
5 hp VFD, 1-Phase 220V to 3-Phase 380V VFD
GK3000-CT0037
$473.54
Best 5 hp variable frequency drive at low price. Single phase 220 volt input to three phase 380 volt output VFD for AC motor speed control, IP20, RS485 enabled, V/F and sensorless vector control mode.
3 hp Horizontal Centrifugal Pump, Single Stage
ATO-HCP-2200W
$1,396.83
Single stage centrifugal pump with horizontal structure, 2kW motor power. Centrifugal water pump with maximum flow 15.2 m³/ h (66.9 gpm), maximum head 29m (95ft) and same diameter of inlet and outlet 50mm (2 inch). 3 phase centrifugal pump has advantages of stable operation, low noise, low failure rate, convenient maintenance and less land occupation.
5 hp VFD, Single Phase to Three Phase VFD
GK3000-2S0037
$294.31
5hp variable frequency drive, single phase to three phase VFD, 17 amps, RS485 enabled, shipping weight 4kg, manufacturer direct sale.
3 hp (2.2kW) 3 phase 2 pole AC Induction Motor
ATO-IM-22002P
$516.76
3 hp/2.2kW three-phase induction motor features 2 poles, 2840rpm rated speed and 7.4Nm nominal torque, with working voltage of 380V 50Hz. Cheap 3-phase asynchronous motor has outstanding performance in the price, mantenance, reliability, durability and operation.
1 hp VFD, Single Phase to Three Phase VFD
GK3000-2S0007
$159.32
1 hp VFD, convert single phase to three phase for AC motor speed controls, IP20, RS485 enabled, shipping weight 2kg, manufacturer direct sale.