Torque sensors have capacity range from 20 Nm, 50 Nm, 100 Nm, 200 Nm, 300 Nm, 500 Nm, 1000 Nm, 2000 Nm, 5000 Nm to 10000 Nm. Torque sensor capacity can be customized according to customer requirements.
After purchasing one ATO torque sensor, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is DC 4-20mA, 0-10V, -5V~+5V, RS485 and RS232.
Specification
| Model | ATO-DYJN-101 |
| Shipping Weight | 2~18kg |
| Capacity Range * | 0-1 Nm ~ 0-10000 Nm |
| Output Signal * | DC 0-20mV, or equip display controller ATO-DPM-DY056 for output signal DC 4-20mA, 0-10V, -5V~+5V, RS485 and RS232 |
| Sensitivity | 1.0-2.0mV/V |
| Zero Balance | ±2%FS |
| Non-linearity | 0.2%FS |
| Hysteresis | 0.05%FS |
| Repeatability | 0.05%FS |
| Creep | 0.05%FS/30min |
| Temperature Drift on Zero | <0.05%F.S/10℃ |
| Temperature Effect on Output | <0.05%F.S/10℃ |
| Operating Temperature | -20℃~+80℃ |
| Humidity | 0~90%RH |
| Impedance | 750Ω |
| Insulation Resistance | ≥5000MΩ/100VDC |
| Stability | 0.3%FS/year |
| Safety Overload | 120%F.S |
| Ultimate Overload | 150%F.S |
| Excitation Voltage | DC 5-15V |
| Material | Alloy steel |
| Protection Class | IP63 (IP65 can be customized, please contact us) |
| Electrical Connection | 5 pin circular connector (Packing included) |
| Cable Length | 3m (Φ5mm) (Packing included) |
| Wiring | EXC+: Red, EXC-: Black, SIG+: Green, SIG-: White |
Feature

- Dual Flange Structure: Utilizes advanced technology to ensure precise torque measurement and stability.
- High-Quality Alloy Material: Made from specially selected high-quality alloy steel for superior durability and reliability.
- Easy Installation: Features a square shape with screws at all four corners for secure installation.
- Bidirectional Load Capability: Offers excellent performance in resisting machine fatigue and high resistance to deformation.
Torque Sensor Dimension
| Capacity | Dimension (mm) | |||||||||
| ΦA | B | ΦC | ΦD | ΦE | ΦF | G | N (Nunber of mounting holes) | W | H | |
| 5~50 Nm | 69 | 65 | 14 | 41 | 6.5 | 57 | 12 | 6 | 22 | 5 |
| 100~300 Nm | 69 | 65 | 22 | 41 | 6.5 | 57 | 12 | 6 | 25 | 5 |
| 500~1000 Nm | 98 | 80 | 30 | 60 | 8.5 | 80 | 15 | 8 | 40 | 6 |
| 2000~5000 Nm | 125 | 96 | 45 | 79 | 13 | 105 | 20 | 8 | 50 | 6 |
| 10000 Nm | 160 | 140 | 40 | 101 | 17 | 130 | 30 | 8 | 80 | 6 |

Wiring Method

Tips: The torque values output from torque sensor has large fluctuations
1. When the torque sensor is used in the test-bed, the torque value in the testing process has a great deviation with the practical value. For example, the reaction torque sensor with a measuring range of 2000 Nm is actually loaded with 600 Nm during the measurement, but the torque sensor shows 1500 Nm, and the torque value is always staying at 1500 Nm no matter how much more load you exert. The torque value can return to zero normally after unloading. Such a kind of situation is caused by electromagnetic interference. In the operation process, the torque value always fluctuates within a certain range no matter how many loads are exerted. It is mainly because of the electromagnetic interference generated by the servo controller or motor in the field, or power leakage of the test-bed.
2. Further confirm if the problem is caused by interference. After unloading and cutting the power supply, take the static torque sensor away, and electrify it to check if it works normally. It is suggested to use an oscilloscope or multimeter to measure if the frequency signal or analog signal of the torque output is normal. If yes, it proves that there is interference at the site or power leakage of the test-bed.
3. Methods of solving the interference:
- Firstly, confirm if the test-bed has power leakage, use the AC function of the multimeter, with one test probe holding in hand contacting with the human body, and the other test probe contacting with the metal part of the test-bed to check if the test-bed, motor or other equipment has the power leakage phenomenon. In the case of power leakage, the multimeter will have a voltage display.
- Confirm if the motor, servo controller, frequency converter, test-bed and other equipment have ground connection (Note that it is earth ground, not power ground).
- The shielded wire of the sensor should have ground connection in connecting the torque sensor. If any display meter is equipped, the meter should be grounding as well. (Note that it is earth ground, not power ground).
- If the above solution is still unable to solve the problem, it is required to install the 1:1 isolation transformer and 1:1 filter after the power supply that power for the torque sensor and the meter.
The above solutions of electromagnetic interference can basically solve the problems of electromagnetic interference of more than 95%.
Also, my assumption is that the sensor has a solid connection with the flange and that the flange could be permanently fixed on a surface. With this, the torque is applied in location (1). Is this correct or would torque need to be applied in location (2)?
I have a few questions about the sensor:
Is there a 0-5V output on the sensor to read easily with an analog input?
What is the recommended supply voltage?
What is the warranty on the product, as $3000 is a lot of money?
If I do not intend on using the RS485, should I leave the two wires unconnected?
How exactly should I connect the RPM /- to acquire the RPM %?
With this, I have a few questions:
In this application, it is critical that our latency is as close to zero as possible. Do you have any specifications on this or are both of these effectively 'real time'?
It appears that the sensors are very similar to one another. Are there any major differences I should be aware of from an electronics design perspective outside of the obvious mounting differences?
How are these sensors affected by vibration?
We will likely be using whichever sensor is selected for quite some time. What is the expected lifecycle for these products as far as replacements being available? Is there any stocking that takes place in the US?
I apologize as it appears that my initial request had a typo. We are sampling at 500-1000Hz, not kHz.
With this, can you please provide answers to the other aspects of the original request? Additionally, can you confirm how the safety overloads are calculated?
The sensor lists 120%FS on a 200NM sensor. Does that mean 240NM (120% of rating) or 440NM (120% over rating)C?
We will cycle about 100,000 times per trial, and we have multiple trials.
Also, we have capture cards that can supply up to 10V.
I see that the sensor can take from 5 to 15V.
Here are my questions :
Do you see an issue with this type of application?
Do you have any better product to suggest to us?
We’d like to have the sensors calibrated either every year or every two years. Is this a service that you offer?
01-03-04-FF-FF-D6-1A-25-BC
How does that data interpreted to Torque Nm ?
Can I just use the digital load cell amplifier?
Thanks
1. The axial load limit of your dual flange torque sensor with a capacity of up to 1000Nm.
2. Recommended electronic components that come with the torque sensor to interpret the result.
3. Do we need any software to interpret the result?
And how do these loads influence the torque measurement?
Thanks for answering