After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.
Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.
Tension and compression load cells have capacity range from 1kg, 5kg, 20kg, 30kg, 100kg, 200kg, 250kg, 300kg to 500kg. Load cell capacity can be customized according to customer requirements.
Specification
| Model | ATO-LCC-DYMH-103 |
| Weight | 0.1kg |
| Capacity Range * | 0kg~500kg |
| Matched Display Controller | ATO-DDC5-CHB (Click it to the controller page) |
| Matched Transmitter | ATO-LCTR-OA (Click it to the transmitter page) |
| Accuracy | 0.3%F.S (linearity + hysteresis + repeatability) |
| Sensitivity | 1.0~1.5mV/V (Low range variations may differ) |
| Creep | ±0.05%F.S/30min |
| Zero Output | ±1%F.S |
| Temperature Effect on Zero | ±0.05%F.S/10℃ |
| Temperature Effect on Output | ±0.05%F.S/10℃ |
| Operating Temperature | -30℃~+70℃ |
| Input Impedance | 400±10Ω |
| Output Impedance | 350±10Ω |
| Insulation Resistance | ≥5000MΩ |
| Safety Overload | 150%F.S |
| Overload Limit | 200%F.S |
| Bridge Voltage (excitation voltage) | DC 5-15V, suggest DC 10V |
| Material | Stainless steel |
| Protection Class | IP67 |
| Cable Length | 2m |
| Wiring | EXC+: Red, EXC-: Black, SIG+: Green, SIG-: White |
Feature

- High-Quality 17-4PH Stainless Steel: Resistant to fatigue and corrosion, offering exceptional strength and durability.
- High Temperature Resistance: Ideal for high-temperature environments, with excellent heat resistance.
- Compact and Lightweight: Small size and low-profile design provide high resistance to offset errors.
- Versatile Application: Suitable for automotive assembly, automation, medical testing, industrial testing, and more.
- Long-Term Stability: Designed for extended use without wear, ensuring stable performance over time.
- Efficient and Reliable: Low hysteresis and excellent long-term stability even under fluctuating temperatures.
- Wide Measurement Range: Capable of measuring a wide range of forces with minimal distortion.
Dimension (unit: mm)
| Capacity | M |
| 1kg, 5kg, 10kg, 15kg, 20kg, 30kg, 50kg | M5*0.8 |
| 60kg, 100kg | M6*1.0 |
| 150kg, 200kg, 250kg, 300kg, 400kg, 500kg | M8*1.25 |
Lead wire=1500mm, screw thread length=8mm

Application

Tips: How do I calibrate the Tension and Compression Load Cell?
Calibration of the Tension and Compression Load Cell is a critical step to ensure that it provides accurate measurements over time. Here’s a detailed guide on how to calibrate the load cell:
- Zero the Load Cell: Before calibration, make sure that the load cell is not under any load, and that the signal is reset to zero. This step eliminates any offset errors.
- Apply Known Weights: Use calibrated test weights or forces that are close to the load cell’s rated capacity. These known weights will serve as references during calibration.
- Record the Output: For each known weight applied, record the load cell’s output signal (e.g., voltage or current). This will help establish a relationship between the applied load and the output signal.
- Adjust the Output Signal: Using the calibration equipment or software, adjust the load cell’s output signal so that it matches the applied weight. This step aligns the system with the known values.
- Verify Calibration: After completing the calibration, apply different known weights (spanning the load cell’s range) and check that the output signal matches the expected values. This helps verify that the calibration is accurate.
2. Will the diameter of the load cell be 15-20 mm for compressive loads upto 1000 kg? We are looking in that range.
3. Will the load cell be calibrated?
4. Is it reliable for carrying out high frequency dynamic load tests (research experiments)? If not do you have such load cells of up to 1000 kg? The time scale I am talking about is 2-5 milli seconds, thus the data required needs to be 100kHz.
When I measure the bridge impedances with a multimeter, I only get 350 Ohms on the Red/White and Green/Black pairings; all other measurements are Open Loop
The top cover of the unit is loose and can fall off of the threads, exposing the internals of the load cell.
When connected to the ATO-LCTR-DY510 load cell amplifier, the output from the amplifier is -13V, which I believe indicates that the amplifier is not seeing a proper connection to the load cell.
This all occurs whether the load cell is in tension, compression, or no load.
Is there any further troubleshooting I can do with this unit?
Is there a recommended installation procedure for these load cells to ensure they are not damaged by the tightening process on the threads?
It seems there are 2 weights needed for calibration,10% rated weight range or more than half the full range?
Secondly is, what is the tolerance of the load cell?
Can it achieve 0.00 for 0-500kg capacity?
What do you mean by F.S in accuracy 0.3%FS?
Refer attached photograph, that shows 1kg weight placed on the load cell at bottom side of the image. Refer the current reading on the multi-meter. It shows 7.2mA. [=(1/5)*16mA 4mA].
Hope this gives clear understanding of the problem we are facing.
For the 5 Kg load cell, 0.3%F.S provides 15gm.
We are not getting readings, even after loading 100gm.
Please check and revert.
You are supporting us from Hong Kong or USA?
Can you confirm, if the resistance is showing OK, that means the load cell should work well. However, after providing the excitation voltage, it did not able to show the output.
Product supplied shall meet the specifications as per catalogue provided. You need to resolve the issue on priority or provide replacement immediately. Our machine delivery stuck due to this issue.
We have a few questions about this load cell:
- Is this cell appropriate for our application?
- Do we need additional electronic components to output the readings?
- What are the units of the output? Can this be modified?
- Does the orientation of the load cell affect the readings?
I hope we can source some load cells as soon as possible to start testing.
Please don't hesitate to let me know if you have any questions regarding the application.
Or would we need to connect all 4 pcs load cell to a DAQ like the MCC USB-200 series? I worry about not having zero and span calibration using something like the MCC. Would we then need to have a transmitter between each load cell and the DAQ, to calibrate span and zero?