Tension and Compression Load Cell, 1 kg - 500 kg

$137.98
Tension and compression load cell can bear both tension and pressure, with good anti-eccentric load performance, low height, all sealed structure and complete specifications. Miniature load cell with optional capacity 1 kg/ 100kg/ 200 kg/ 300kg/ 500 kg is suited to use in restricted spaces, such as using in vehicle/test instrument/laminator measurement and control.
SKU: ATO-LC-TC01
*
Availability: In stock
Free Shipping
Delivery date: 2-12 days

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Tension and compression load cells have capacity range from 1kg, 5kg, 20kg, 30kg, 100kg, 200kg, 250kg, 300kg to 500kg. Load cell capacity can be customized according to customer requirements.

Specification

ModelATO-LCC-DYMH-103
Weight0.1kg
Capacity Range *0kg~500kg
Matched Display ControllerATO-DDC5-CHB (Click it to the controller page)
Matched TransmitterATO-LCTR-OA (Click it to the transmitter page)
Accuracy0.3%F.S (linearity + hysteresis + repeatability)
Sensitivity1.0~1.5mV/V (Low range variations may differ)
Creep±0.05%F.S/30min
Zero Output±1%F.S
Temperature Effect on Zero±0.05%F.S/10℃
Temperature Effect on Output±0.05%F.S/10℃
Operating Temperature-30℃~+70℃
Input Impedance400±10Ω
Output Impedance350±10Ω
Insulation Resistance≥5000MΩ
Safety Overload150%F.S
Overload Limit200%F.S
Bridge Voltage (excitation voltage)DC 5-15V, suggest DC 10V
MaterialStainless steel
Protection ClassIP67
Cable Length2m
WiringEXC+: Red, EXC-: Black, SIG+: Green, SIG-: White


Feature

Tension and compression load cell 1kg to 200kg feature

  • High-Quality 17-4PH Stainless Steel: Resistant to fatigue and corrosion, offering exceptional strength and durability.
  • High Temperature Resistance: Ideal for high-temperature environments, with excellent heat resistance.
  • Compact and Lightweight: Small size and low-profile design provide high resistance to offset errors.
  • Versatile Application: Suitable for automotive assembly, automation, medical testing, industrial testing, and more.
  • Long-Term Stability: Designed for extended use without wear, ensuring stable performance over time.
  • Efficient and Reliable: Low hysteresis and excellent long-term stability even under fluctuating temperatures.
  • Wide Measurement Range: Capable of measuring a wide range of forces with minimal distortion.

Dimension (unit: mm)

CapacityM
1kg, 5kg, 10kg, 15kg, 20kg, 30kg, 50kgM5*0.8
60kg, 100kgM6*1.0
150kg, 200kg, 250kg, 300kg, 400kg, 500kgM8*1.25

Lead wire=1500mm, screw thread length=8mm

Tension and compression load cell 1kg to 200kg dimension

Application

Tension and compression load cell 1kg to 200kg-application

Tips: How do I calibrate the Tension and Compression Load Cell?

Calibration of the Tension and Compression Load Cell is a critical step to ensure that it provides accurate measurements over time. Here’s a detailed guide on how to calibrate the load cell:

  • Zero the Load Cell: Before calibration, make sure that the load cell is not under any load, and that the signal is reset to zero. This step eliminates any offset errors.
  • Apply Known Weights: Use calibrated test weights or forces that are close to the load cell’s rated capacity. These known weights will serve as references during calibration.
  • Record the Output: For each known weight applied, record the load cell’s output signal (e.g., voltage or current). This will help establish a relationship between the applied load and the output signal.
  • Adjust the Output Signal: Using the calibration equipment or software, adjust the load cell’s output signal so that it matches the applied weight. This step aligns the system with the known values.
  • Verify Calibration: After completing the calibration, apply different known weights (spanning the load cell’s range) and check that the output signal matches the expected values. This helps verify that the calibration is accurate.

In this video, we've presented two types of general-purpose micro load cells from ATO that can measure both compression and tensile forces. The capacitiy ranges are 1kg to 500kg, and 3kg to 500kg. Both are made of nickle-plated stainless steel, featuring corrosion-resistant and rugged construction. Incorporating metal foil strain gauging, these precision load cells will deliver excellent stability, reliability and accuracy under various industrial circumstances.

In this video, ATO offers a variety of load cells and weigh modules designed for your applications.

Product reviews
5kg micro load cells for tension test
5
Nathan
Avatar
7/4/2019 9:46 PM
I just bought 5 pcs 5kg micro load cells for tension test. The tension load cells have highly sensitive and good repeatability precision. The measured data is really accurate and stable. I am also satisfied with the delivery time. It takes about a week to receive them.
Was this review helpful? Yes No (0/0)
The output signal of the load cell
5
Emanuel
Avatar
6/10/2021 9:35 PM
Please advice the out put signal of the load cell.
Was this review helpful? Yes No (0/0)
ATO Responded
The output signal of the load cell is 0-20mV.
I am interested in your load cell. Can you recommend one for me?
5
Roth
Avatar
11/14/2021 8:14 PM
I am working at a research station in Norway and we have 12 loads (50 kg and 300 kg) which we want to connect to a computer, so that we can follow the weight over time. Is that possible, and what do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
We can recommend using our multi-channel junction box to connect the load cell together getting one output, and then connect the junction box output signal to our digital load cell amplifier, to output RS485 signal, and then connect to the computer software through the 485 signal to monitor the weight information.
Can you provide some advice for my test?
5
Alston
Avatar
5/24/2022 11:54 PM
I do impact testing for football collisions. I have a pendulum with a 15.3 kg mass, on which the load cell is mounted. I impact a head form which has the 6DXPro mounted inside. I record 4 seconds of data from the load cell, 3 accelerometer channels, and 3 gyroscope channels. For each of the 5 tests I performed the linear acceleration and angular velocity profiles are consistent, the load cell readings however changed drastically. They increased with each test from 29 kg to 49 kg to 108 kg to 120 kg then drastically dropped to 10 kg on my last test. Any insight you may be able to provide is greatly appreciated.
Was this review helpful? Yes No (0/0)
ATO Responded
The structure of the model DYMH-103 you purchased is not suitable for impact testing. When installed horizontally, the weight of the sensor itself will also have a certain impact on the measurement. Therefore, the output measurement value will be unstable and inaccurate under these factors. For your testing, it is recommended that you use our MH-105. When installing, please install it vertically, and use the vertical direction for impact testing.
I have the following queries.
5
Jonathan
Avatar
5/25/2022 2:09 AM
1. Can it be customizable to take compressive loads up to 1000 kg? Will the expected delivery date be still 12 days? If not do you have any estimate?
2. Will the diameter of the load cell be 15-20 mm for compressive loads upto 1000 kg? We are looking in that range.
3. Will the load cell be calibrated?
4. Is it reliable for carrying out high frequency dynamic load tests (research experiments)? If not do you have such load cells of up to 1000 kg? The time scale I am talking about is 2-5 milli seconds, thus the data required needs to be 100kHz.
Was this review helpful? Yes No (0/0)
ATO Responded
1.Sorry, we can't produce 15-20 mm diameter, our 1000kg load cell is 51mm in diameter.
2. The response frequency of our load cell is 1kHz, which cannot reach the 100kHz you require.
Correct information of load cell
5
pyng
Avatar
7/3/2022 10:46 PM
While checking the load cell specifications, I noticed some differences between the information in the catalog (pdf file) and the website overview (e.g. Excitation voltage, Accuracy). Which specifications are correct?
Was this review helpful? Yes No (0/0)
ATO Responded
The information on the page is correct, the information on the PDF is wrong, sorry for the confusion.
Problems about ATO load cell.
5
Carla
Avatar
7/27/2022 7:13 PM
I have an ATO-LC-TC01 load cell, which I think is malfunctioning and need support with it. The problem is as follows:
When I measure the bridge impedances with a multimeter, I only get 350 Ohms on the Red/White and Green/Black pairings; all other measurements are Open Loop
The top cover of the unit is loose and can fall off of the threads, exposing the internals of the load cell.
When connected to the ATO-LCTR-DY510 load cell amplifier, the output from the amplifier is -13V, which I believe indicates that the amplifier is not seeing a proper connection to the load cell.
This all occurs whether the load cell is in tension, compression, or no load.
Is there any further troubleshooting I can do with this unit?
Is there a recommended installation procedure for these load cells to ensure they are not damaged by the tightening process on the threads?
Was this review helpful? Yes No (0/0)
ATO Responded
If the red/white and green/black pairings are only 350 ohms when the multimeter measures the bridge impedance, and all other measurements are open loop, it means that the sensor is damaged inside. When installing the load cell, do not screw the screw to the end, and the screw should not touch the ring surface of the sensor, otherwise the sensor may be damaged.
Which interface recovers the signal of this tension and compression load cell?
5
DeLisle
Avatar
12/12/2022 8:15 PM
I would like to know which interface recovers the signal of this tension and compression load cell. I couldn’t find it on your page.
Was this review helpful? Yes No (0/0)
ATO Responded
This load sensor has no recovery signal interface, its output is 0-20mV, and you can get an analog signal or RS-485 if you connect its output to the load cell transmitter/amplifier.
Some question of load cell, 1kg-500kg
5
herman
Avatar
3/1/2023 7:56 PM
Would like to clarify a few things for recent purchase load cell 0-500 capacity.
It seems there are 2 weights needed for calibration,10% rated weight range or more than half the full range?
Secondly is, what is the tolerance of the load cell?
Can it achieve 0.00 for 0-500kg capacity?
What do you mean by F.S in accuracy 0.3%FS?
Was this review helpful? Yes No (0/0)
ATO Responded
1. It is also acceptable to calibrate the rated weight range of 10% of the sensor range or more than half the full range.
2. 0.3%F.S means: the accuracy error is 500kg*0.003=1.5kg.
Some problems about the calibration
5
Frederick
Avatar
3/9/2023 11:05 PM
I did the whole calibration and I put 2 kg thing during the weight calibration to verify the weight then after the set up. I put 2 kg thing on top of the load cell still show 1.7 kg. I am wondering why.
Was this review helpful? Yes No (0/0)
ATO Responded
We think that in your case, the calibration was not performed correctly. When calibrating, you need to complete 2 steps. To calibrate the zero point without load first, you need to adjust the zero point potentiometer to display the signal output to 0. After completion, perform load target point calibration. For example, the weight is 50Kg, which is equivalent to 10% of the full scale of 500Kg, then the output voltage signal should be 10% of 5V, which is 0.5V, so you need to adjust the span potentiometer until the output signal shows 0.5V.
500kg load cell full scale
5
Demetrius
Avatar
3/30/2023 3:35 PM
In documentation of DY510 Weight Transmitter, it states that if it is desired to calibrate such that load cell can measure tension and compression, 0 load point must be set to at 12 mA, so that min/max is at 4mA/20mA. I purchased 500kg load cell, and I was wondering if 500kg means that the full scale of the load cell is 1000 kg [-500 500]. In addition, I was wondering if it were possible to set range to [-250 750]. These loads cell will be used on a vehicle, and while I don't expect to have more than 500kg, that scenario is more likely than -500kg.
Was this review helpful? Yes No (0/0)
ATO Responded
No, whether it is compression or tension, the specification of 500kg can only be (-500, +500), exceeding this value may damage the sensor. So its capacity is not 1000kg.. However, the transmitter is different, it only detects the voltage signal, it is very flexible, you can adjust it according to your needs, they are fundamentally not much related.
Some question of tension load cell
5
Betty
Avatar
5/9/2023 8:39 PM
Thanks for your email. As per specification we have 15g resolution (0.3% of F.S = 5000gm*0.03 = 15g). This is not accuracy figure as per my understanding.
Refer attached photograph, that shows 1kg weight placed on the load cell at bottom side of the image. Refer the current reading on the multi-meter. It shows 7.2mA. [=(1/5)*16mA 4mA].
Hope this gives clear understanding of the problem we are facing.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for your feedback.
1. DYMH-103 5kg the accuracy of this sensor is 0.3%, and the minimum accuracy is 15g, but there will be an error of about 10g.
We recommend that you replace the sensor ATO-LCS-DYLY-108, its accuracy is 0.05%.
Please refer to the link: https://www.ato.com/micro-load-cell-s-type-0kg-to-200kg
2. The current reading on the multi-meter in your attached picture shows 7.2mA, which is a normal reading, no problem.
Accuracy results of tension load cell
5
crane
Avatar
5/9/2023 11:47 PM
We are not getting specified "Accuracy" results.
For the 5 Kg load cell, 0.3%F.S provides 15gm.
We are not getting readings, even after loading 100gm.
Please check and revert.
You are supporting us from Hong Kong or USA?
Was this review helpful? Yes No (0/0)
ATO Responded
Change the decimal point of the sensor to 0, and it will show 5kg.
Please refer to the attached DY510 manual.
Solve the load cell problem
5
doro
Avatar
6/13/2023 7:11 PM
We have checked one of the load cell from the faulty ones and found that it is showing 350 Ohm resistance at the input side instead of 400 Ohm ( which is  /- 10 Ohm) and 350 Ohm at the output side.
Can you confirm, if the resistance is showing OK, that means the load cell should work well. However, after providing the excitation voltage, it did not able to show the output.
Product supplied shall meet the specifications as per catalogue provided. You need to resolve the issue on priority or provide replacement immediately. Our machine delivery stuck due to this issue.
Was this review helpful? Yes No (0/0)
ATO Responded
1. It is normal in showing 350 Ohm resistance at the input side.
2. Perhaps we can help to solve the your problems before the return.  Please check the quality of the sensor again, the method of judging the quality of the load cell:
1) Find the connection terminal of the sensor in the weighing instrument (or amplifier). When the connection circuit of the measuring sensor is normal, the red and black wires (EX+, EX-) of the sensor are the excitation voltage, generally 5v power supply voltage.
2) Remove the green and white line (SIG+, SIG-) signal line when the sensor is unloaded, set the multi-meter voltage mv gear, and then directly measure the mv voltage of the green and white line. If the measurement result does not exceed 0.3mv, then press the sensor with your hand. If you see obvious mv voltage changes, it means that the sensor is good. If the mv voltage of the green and white line exceeds 0.3mv, there is a problem.
Hope my explanation is able to assist you. Look forward to your reply.
We have a few questions about this load cell
5
bai
Avatar
7/24/2023 8:47 PM
We're looking to source a load cell to use in an impact test of up to 3-4 kN. The one we think may be a good fit for this application is the ATO-LC-TC01. The load cell will be sandwiched between two plates, one will be receiving the impact and the other one will be fixed.

We have a few questions about this load cell:
- Is this cell appropriate for our application?
- Do we need additional electronic components to output the readings?
- What are the units of the output? Can this be modified?
- Does the orientation of the load cell affect the readings?

I hope we can source some load cells as soon as possible to start testing.
Please don't hesitate to let me know if you have any questions regarding the application.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our load cell is not suitable for impact tests.
The sensor measurement reading will be inaccurate and unstable.
Tension and Compression Load Cell
5
Sameh
Avatar
11/15/2023 7:48 PM
Do approximately 52mm from bearing surface to bearing surface with the eyes attached?
Was this review helpful? Yes No (0/0)
ATO Responded
The total length of the sensor body is 37mm (including the screws at both ends), and the total length of the eye nut is 36.6mm.  Therefore, after installing the eye nuts at both ends, the total length of the sensor will Not exceed 109mm (37+36+36). This is because the eye nuts need to be fixed into the sensor screw.
Problems when using the tension and compression load cell
4
Santos
Avatar
4/8/2024 2:37 AM
We purchased 4 x load cells. For out test configuration, we plan to read and log force values from each load cell individually throughout the test. Is this achievable using the junction box and transmitter from ATO?
Or would we need to connect all 4 pcs load cell to a DAQ like the MCC USB-200 series? I worry about not having zero and span calibration using something like the MCC. Would we then need to have a transmitter between each load cell and the DAQ, to calibrate span and zero?
Was this review helpful? Yes No (0/0)
ATO Responded
If you want to read and record the force value of each load cell separately during the test, you will need to install a transmitter between each load cell and the DAQ.
If you want to read the force values of 4 load cells together during the test, you only need to use a junction box, a transmitter and DAQ to achieve it. Regarding DAQ software, you can refer to this model SKU: ATO-DPM-DY800, which can configure DAQ software.
About raspberry pi
5
Tigreur
Avatar
12/13/2024 12:16 AM
Is there any reason I wouldn't be able to use a standard HX711 converter to amplify the load cell to be readable with a raspberry pi? I don't see any reason this wouldn't work, but only see instructions for using ATO amplifiers with traditional PLCs. Thanks
Was this review helpful? Yes No (0/0)
ATO Responded
Our load cell ATO-LCC-DYMH-103 can match our amplifier to output analog signals and then connect to PLC. But we are Not sure whether the standard HX711 converter is compatible with our load cell. You need to understand what type of signal this raspberry pi supports to read, or you should consult the supplier of raspberry pi.
About load cell
5
Tijuana
Avatar
5/26/2025 8:57 PM
I need a load cell with an axial load of 44.5 lbs (max) (range 0-50 lbs), an accuracy of ±0.5 or less, a threaded rod on both ends for easy mounting in a test fixture, and a maximum range of 50 lbs.
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-LC-TC01 sensor is capable of withstanding axial loads and concentric forces with an accuracy of 0.3% of full scale. Eccentric loads are not recommended, and the nuts mounted on both sides should not contact the annular level.
About voltage
5
Sawyor
Avatar
6/17/2025 8:04 PM
The bridge voltage listed on your ATO-LCC-DYMH-103 load cell product page is 5-15V, but the PDF datasheet says 10-15V. Can you explain which range is correct? Our system is rated for 5V only.
Was this review helpful? Yes No (0/0)
ATO Responded
We confirm that our ATO-LCC-DYMH-103 load cell can be used with a 5V bridge voltage, no problem.
Data sheet
5
nektaria
Avatar
2/3/2026 6:18 PM
Hello, where is the datasheet for this load cell? The catalog is linked but I cannot see the data sheet with specifications and wave forms for the sensor's dynamic response.
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, you can contact our sales team for relevant information: sales@ato.com, service@ato.com
Two questions
4
Ivank
Avatar
3/11/2026 12:28 AM
I need an ATO-LCC-DYMH-103 load cell and have two questions. First, what are the accurate reading resolutions (accuracy) of the 1 kg and 2.5 kg load cells? Second, what type of cable does the load cell come with? We need a specific type of cable connection (avionics interface).
Was this review helpful? Yes No (0/0)
ATO Responded
This load cell has a default lead output of 2 meters. Do you want to configure it with an aviation connector cable? What is the required cable length? The sensor's accuracy is 0.3%F.S.
Cable diameter
5
George
Avatar
4/10/2026 3:05 AM
What is the diameter of the cable connected to the ATO-LC-TC01 (5kg)? I am threading the cable through a cable connector.
Was this review helpful? Yes No (0/0)
ATO Responded
The wire diameter for this load-cel unit ATO-LC-TC01 (5kg) is φ3*2mm.
Fatigue Testing
5
Harpern
Avatar
4/16/2026 12:06 AM
Hello, I am very interested in purchasing the ATO-LCC-DYMH-103 load cell. Can this load cell undergo fatigue testing? If so, what is its maximum loading frequency? Thank you!
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, we do not recommend fatigue testing.
Question
5
Julia
Avatar
5/23/2026 12:34 PM
What is the diameter of the cable connected to the ATO-LC-TC01 (100kg)?
Was this review helpful? Yes No (0/0)
ATO Responded
It is a 3mm multi-core cable.
Question
5
Julia
Avatar
5/28/2026 10:22 PM
What is the grade of the threaded stud?
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, for more information, please contact our sales team: sales@ato.com, service@ato.com. We will provide you with detailed answers.
Some Questions
4
Kurtes
Avatar
10/29/2026 8:59 PM
Hello, I intend to purchase a miniature tension/compression sensor with a 1 kg range. I plan to use it for low-force mechanical testing in the tensile and compressive directions (approximately 0.1 to 10 N). Could you please confirm whether the sensor's overall accuracy (approximately 0.03 N) at 0.3% F.S. (full scale) is applicable at a 1 kg range? Additionally, could you provide specific parameter values for nonlinearity, hysteresis, repeatability, creep, and safe overload at this range?
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-LC-TC01 model has an overall accuracy of 0.3% F.S. (approximately 0.03 N) at a 1 kg range. The safe overload is 150% F.S. (1.5 kg), and the overload limit is 200% F.S. (2 kg). Linearity, hysteresis, and repeatability parameters can be found in the product manual on the website: https://www.ato.com/Content/doc/Load-cell-catalog.pdf
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Tension and compression load cells have capacity range from 1kg, 5kg, 20kg, 30kg, 100kg, 200kg, 250kg, 300kg to 500kg. Load cell capacity can be customized according to customer requirements.

Specification

ModelATO-LCC-DYMH-103
Weight0.1kg
Capacity Range *0kg~500kg
Matched Display ControllerATO-DDC5-CHB (Click it to the controller page)
Matched TransmitterATO-LCTR-OA (Click it to the transmitter page)
Accuracy0.3%F.S (linearity + hysteresis + repeatability)
Sensitivity1.0~1.5mV/V (Low range variations may differ)
Creep±0.05%F.S/30min
Zero Output±1%F.S
Temperature Effect on Zero±0.05%F.S/10℃
Temperature Effect on Output±0.05%F.S/10℃
Operating Temperature-30℃~+70℃
Input Impedance400±10Ω
Output Impedance350±10Ω
Insulation Resistance≥5000MΩ
Safety Overload150%F.S
Overload Limit200%F.S
Bridge Voltage (excitation voltage)DC 5-15V, suggest DC 10V
MaterialStainless steel
Protection ClassIP67
Cable Length2m
WiringEXC+: Red, EXC-: Black, SIG+: Green, SIG-: White


Feature

Tension and compression load cell 1kg to 200kg feature

  • High-Quality 17-4PH Stainless Steel: Resistant to fatigue and corrosion, offering exceptional strength and durability.
  • High Temperature Resistance: Ideal for high-temperature environments, with excellent heat resistance.
  • Compact and Lightweight: Small size and low-profile design provide high resistance to offset errors.
  • Versatile Application: Suitable for automotive assembly, automation, medical testing, industrial testing, and more.
  • Long-Term Stability: Designed for extended use without wear, ensuring stable performance over time.
  • Efficient and Reliable: Low hysteresis and excellent long-term stability even under fluctuating temperatures.
  • Wide Measurement Range: Capable of measuring a wide range of forces with minimal distortion.

Dimension (unit: mm)

CapacityM
1kg, 5kg, 10kg, 15kg, 20kg, 30kg, 50kgM5*0.8
60kg, 100kgM6*1.0
150kg, 200kg, 250kg, 300kg, 400kg, 500kgM8*1.25

Lead wire=1500mm, screw thread length=8mm

Tension and compression load cell 1kg to 200kg dimension

Application

Tension and compression load cell 1kg to 200kg-application

Tips: How do I calibrate the Tension and Compression Load Cell?

Calibration of the Tension and Compression Load Cell is a critical step to ensure that it provides accurate measurements over time. Here’s a detailed guide on how to calibrate the load cell:

  • Zero the Load Cell: Before calibration, make sure that the load cell is not under any load, and that the signal is reset to zero. This step eliminates any offset errors.
  • Apply Known Weights: Use calibrated test weights or forces that are close to the load cell’s rated capacity. These known weights will serve as references during calibration.
  • Record the Output: For each known weight applied, record the load cell’s output signal (e.g., voltage or current). This will help establish a relationship between the applied load and the output signal.
  • Adjust the Output Signal: Using the calibration equipment or software, adjust the load cell’s output signal so that it matches the applied weight. This step aligns the system with the known values.
  • Verify Calibration: After completing the calibration, apply different known weights (spanning the load cell’s range) and check that the output signal matches the expected values. This helps verify that the calibration is accurate.
Product reviews
5kg micro load cells for tension test
5
Nathan
Avatar
7/4/2019 9:46 PM
I just bought 5 pcs 5kg micro load cells for tension test. The tension load cells have highly sensitive and good repeatability precision. The measured data is really accurate and stable. I am also satisfied with the delivery time. It takes about a week to receive them.
Was this review helpful? Yes No (0/0)
The output signal of the load cell
5
Emanuel
Avatar
6/10/2021 9:35 PM
Please advice the out put signal of the load cell.
Was this review helpful? Yes No (0/0)
ATO Responded
The output signal of the load cell is 0-20mV.
I am interested in your load cell. Can you recommend one for me?
5
Roth
Avatar
11/14/2021 8:14 PM
I am working at a research station in Norway and we have 12 loads (50 kg and 300 kg) which we want to connect to a computer, so that we can follow the weight over time. Is that possible, and what do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
We can recommend using our multi-channel junction box to connect the load cell together getting one output, and then connect the junction box output signal to our digital load cell amplifier, to output RS485 signal, and then connect to the computer software through the 485 signal to monitor the weight information.
Can you provide some advice for my test?
5
Alston
Avatar
5/24/2022 11:54 PM
I do impact testing for football collisions. I have a pendulum with a 15.3 kg mass, on which the load cell is mounted. I impact a head form which has the 6DXPro mounted inside. I record 4 seconds of data from the load cell, 3 accelerometer channels, and 3 gyroscope channels. For each of the 5 tests I performed the linear acceleration and angular velocity profiles are consistent, the load cell readings however changed drastically. They increased with each test from 29 kg to 49 kg to 108 kg to 120 kg then drastically dropped to 10 kg on my last test. Any insight you may be able to provide is greatly appreciated.
Was this review helpful? Yes No (0/0)
ATO Responded
The structure of the model DYMH-103 you purchased is not suitable for impact testing. When installed horizontally, the weight of the sensor itself will also have a certain impact on the measurement. Therefore, the output measurement value will be unstable and inaccurate under these factors. For your testing, it is recommended that you use our MH-105. When installing, please install it vertically, and use the vertical direction for impact testing.
I have the following queries.
5
Jonathan
Avatar
5/25/2022 2:09 AM
1. Can it be customizable to take compressive loads up to 1000 kg? Will the expected delivery date be still 12 days? If not do you have any estimate?
2. Will the diameter of the load cell be 15-20 mm for compressive loads upto 1000 kg? We are looking in that range.
3. Will the load cell be calibrated?
4. Is it reliable for carrying out high frequency dynamic load tests (research experiments)? If not do you have such load cells of up to 1000 kg? The time scale I am talking about is 2-5 milli seconds, thus the data required needs to be 100kHz.
Was this review helpful? Yes No (0/0)
ATO Responded
1.Sorry, we can't produce 15-20 mm diameter, our 1000kg load cell is 51mm in diameter.
2. The response frequency of our load cell is 1kHz, which cannot reach the 100kHz you require.
Correct information of load cell
5
pyng
Avatar
7/3/2022 10:46 PM
While checking the load cell specifications, I noticed some differences between the information in the catalog (pdf file) and the website overview (e.g. Excitation voltage, Accuracy). Which specifications are correct?
Was this review helpful? Yes No (0/0)
ATO Responded
The information on the page is correct, the information on the PDF is wrong, sorry for the confusion.
Problems about ATO load cell.
5
Carla
Avatar
7/27/2022 7:13 PM
I have an ATO-LC-TC01 load cell, which I think is malfunctioning and need support with it. The problem is as follows:
When I measure the bridge impedances with a multimeter, I only get 350 Ohms on the Red/White and Green/Black pairings; all other measurements are Open Loop
The top cover of the unit is loose and can fall off of the threads, exposing the internals of the load cell.
When connected to the ATO-LCTR-DY510 load cell amplifier, the output from the amplifier is -13V, which I believe indicates that the amplifier is not seeing a proper connection to the load cell.
This all occurs whether the load cell is in tension, compression, or no load.
Is there any further troubleshooting I can do with this unit?
Is there a recommended installation procedure for these load cells to ensure they are not damaged by the tightening process on the threads?
Was this review helpful? Yes No (0/0)
ATO Responded
If the red/white and green/black pairings are only 350 ohms when the multimeter measures the bridge impedance, and all other measurements are open loop, it means that the sensor is damaged inside. When installing the load cell, do not screw the screw to the end, and the screw should not touch the ring surface of the sensor, otherwise the sensor may be damaged.
Which interface recovers the signal of this tension and compression load cell?
5
DeLisle
Avatar
12/12/2022 8:15 PM
I would like to know which interface recovers the signal of this tension and compression load cell. I couldn’t find it on your page.
Was this review helpful? Yes No (0/0)
ATO Responded
This load sensor has no recovery signal interface, its output is 0-20mV, and you can get an analog signal or RS-485 if you connect its output to the load cell transmitter/amplifier.
Some question of load cell, 1kg-500kg
5
herman
Avatar
3/1/2023 7:56 PM
Would like to clarify a few things for recent purchase load cell 0-500 capacity.
It seems there are 2 weights needed for calibration,10% rated weight range or more than half the full range?
Secondly is, what is the tolerance of the load cell?
Can it achieve 0.00 for 0-500kg capacity?
What do you mean by F.S in accuracy 0.3%FS?
Was this review helpful? Yes No (0/0)
ATO Responded
1. It is also acceptable to calibrate the rated weight range of 10% of the sensor range or more than half the full range.
2. 0.3%F.S means: the accuracy error is 500kg*0.003=1.5kg.
Some problems about the calibration
5
Frederick
Avatar
3/9/2023 11:05 PM
I did the whole calibration and I put 2 kg thing during the weight calibration to verify the weight then after the set up. I put 2 kg thing on top of the load cell still show 1.7 kg. I am wondering why.
Was this review helpful? Yes No (0/0)
ATO Responded
We think that in your case, the calibration was not performed correctly. When calibrating, you need to complete 2 steps. To calibrate the zero point without load first, you need to adjust the zero point potentiometer to display the signal output to 0. After completion, perform load target point calibration. For example, the weight is 50Kg, which is equivalent to 10% of the full scale of 500Kg, then the output voltage signal should be 10% of 5V, which is 0.5V, so you need to adjust the span potentiometer until the output signal shows 0.5V.
500kg load cell full scale
5
Demetrius
Avatar
3/30/2023 3:35 PM
In documentation of DY510 Weight Transmitter, it states that if it is desired to calibrate such that load cell can measure tension and compression, 0 load point must be set to at 12 mA, so that min/max is at 4mA/20mA. I purchased 500kg load cell, and I was wondering if 500kg means that the full scale of the load cell is 1000 kg [-500 500]. In addition, I was wondering if it were possible to set range to [-250 750]. These loads cell will be used on a vehicle, and while I don't expect to have more than 500kg, that scenario is more likely than -500kg.
Was this review helpful? Yes No (0/0)
ATO Responded
No, whether it is compression or tension, the specification of 500kg can only be (-500, +500), exceeding this value may damage the sensor. So its capacity is not 1000kg.. However, the transmitter is different, it only detects the voltage signal, it is very flexible, you can adjust it according to your needs, they are fundamentally not much related.
Some question of tension load cell
5
Betty
Avatar
5/9/2023 8:39 PM
Thanks for your email. As per specification we have 15g resolution (0.3% of F.S = 5000gm*0.03 = 15g). This is not accuracy figure as per my understanding.
Refer attached photograph, that shows 1kg weight placed on the load cell at bottom side of the image. Refer the current reading on the multi-meter. It shows 7.2mA. [=(1/5)*16mA 4mA].
Hope this gives clear understanding of the problem we are facing.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for your feedback.
1. DYMH-103 5kg the accuracy of this sensor is 0.3%, and the minimum accuracy is 15g, but there will be an error of about 10g.
We recommend that you replace the sensor ATO-LCS-DYLY-108, its accuracy is 0.05%.
Please refer to the link: https://www.ato.com/micro-load-cell-s-type-0kg-to-200kg
2. The current reading on the multi-meter in your attached picture shows 7.2mA, which is a normal reading, no problem.
Accuracy results of tension load cell
5
crane
Avatar
5/9/2023 11:47 PM
We are not getting specified "Accuracy" results.
For the 5 Kg load cell, 0.3%F.S provides 15gm.
We are not getting readings, even after loading 100gm.
Please check and revert.
You are supporting us from Hong Kong or USA?
Was this review helpful? Yes No (0/0)
ATO Responded
Change the decimal point of the sensor to 0, and it will show 5kg.
Please refer to the attached DY510 manual.
Solve the load cell problem
5
doro
Avatar
6/13/2023 7:11 PM
We have checked one of the load cell from the faulty ones and found that it is showing 350 Ohm resistance at the input side instead of 400 Ohm ( which is  /- 10 Ohm) and 350 Ohm at the output side.
Can you confirm, if the resistance is showing OK, that means the load cell should work well. However, after providing the excitation voltage, it did not able to show the output.
Product supplied shall meet the specifications as per catalogue provided. You need to resolve the issue on priority or provide replacement immediately. Our machine delivery stuck due to this issue.
Was this review helpful? Yes No (0/0)
ATO Responded
1. It is normal in showing 350 Ohm resistance at the input side.
2. Perhaps we can help to solve the your problems before the return.  Please check the quality of the sensor again, the method of judging the quality of the load cell:
1) Find the connection terminal of the sensor in the weighing instrument (or amplifier). When the connection circuit of the measuring sensor is normal, the red and black wires (EX+, EX-) of the sensor are the excitation voltage, generally 5v power supply voltage.
2) Remove the green and white line (SIG+, SIG-) signal line when the sensor is unloaded, set the multi-meter voltage mv gear, and then directly measure the mv voltage of the green and white line. If the measurement result does not exceed 0.3mv, then press the sensor with your hand. If you see obvious mv voltage changes, it means that the sensor is good. If the mv voltage of the green and white line exceeds 0.3mv, there is a problem.
Hope my explanation is able to assist you. Look forward to your reply.
We have a few questions about this load cell
5
bai
Avatar
7/24/2023 8:47 PM
We're looking to source a load cell to use in an impact test of up to 3-4 kN. The one we think may be a good fit for this application is the ATO-LC-TC01. The load cell will be sandwiched between two plates, one will be receiving the impact and the other one will be fixed.

We have a few questions about this load cell:
- Is this cell appropriate for our application?
- Do we need additional electronic components to output the readings?
- What are the units of the output? Can this be modified?
- Does the orientation of the load cell affect the readings?

I hope we can source some load cells as soon as possible to start testing.
Please don't hesitate to let me know if you have any questions regarding the application.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our load cell is not suitable for impact tests.
The sensor measurement reading will be inaccurate and unstable.
Tension and Compression Load Cell
5
Sameh
Avatar
11/15/2023 7:48 PM
Do approximately 52mm from bearing surface to bearing surface with the eyes attached?
Was this review helpful? Yes No (0/0)
ATO Responded
The total length of the sensor body is 37mm (including the screws at both ends), and the total length of the eye nut is 36.6mm.  Therefore, after installing the eye nuts at both ends, the total length of the sensor will Not exceed 109mm (37+36+36). This is because the eye nuts need to be fixed into the sensor screw.
Problems when using the tension and compression load cell
4
Santos
Avatar
4/8/2024 2:37 AM
We purchased 4 x load cells. For out test configuration, we plan to read and log force values from each load cell individually throughout the test. Is this achievable using the junction box and transmitter from ATO?
Or would we need to connect all 4 pcs load cell to a DAQ like the MCC USB-200 series? I worry about not having zero and span calibration using something like the MCC. Would we then need to have a transmitter between each load cell and the DAQ, to calibrate span and zero?
Was this review helpful? Yes No (0/0)
ATO Responded
If you want to read and record the force value of each load cell separately during the test, you will need to install a transmitter between each load cell and the DAQ.
If you want to read the force values of 4 load cells together during the test, you only need to use a junction box, a transmitter and DAQ to achieve it. Regarding DAQ software, you can refer to this model SKU: ATO-DPM-DY800, which can configure DAQ software.
About raspberry pi
5
Tigreur
Avatar
12/13/2024 12:16 AM
Is there any reason I wouldn't be able to use a standard HX711 converter to amplify the load cell to be readable with a raspberry pi? I don't see any reason this wouldn't work, but only see instructions for using ATO amplifiers with traditional PLCs. Thanks
Was this review helpful? Yes No (0/0)
ATO Responded
Our load cell ATO-LCC-DYMH-103 can match our amplifier to output analog signals and then connect to PLC. But we are Not sure whether the standard HX711 converter is compatible with our load cell. You need to understand what type of signal this raspberry pi supports to read, or you should consult the supplier of raspberry pi.
About load cell
5
Tijuana
Avatar
5/26/2025 8:57 PM
I need a load cell with an axial load of 44.5 lbs (max) (range 0-50 lbs), an accuracy of ±0.5 or less, a threaded rod on both ends for easy mounting in a test fixture, and a maximum range of 50 lbs.
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-LC-TC01 sensor is capable of withstanding axial loads and concentric forces with an accuracy of 0.3% of full scale. Eccentric loads are not recommended, and the nuts mounted on both sides should not contact the annular level.
About voltage
5
Sawyor
Avatar
6/17/2025 8:04 PM
The bridge voltage listed on your ATO-LCC-DYMH-103 load cell product page is 5-15V, but the PDF datasheet says 10-15V. Can you explain which range is correct? Our system is rated for 5V only.
Was this review helpful? Yes No (0/0)
ATO Responded
We confirm that our ATO-LCC-DYMH-103 load cell can be used with a 5V bridge voltage, no problem.
Data sheet
5
nektaria
Avatar
2/3/2026 6:18 PM
Hello, where is the datasheet for this load cell? The catalog is linked but I cannot see the data sheet with specifications and wave forms for the sensor's dynamic response.
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, you can contact our sales team for relevant information: sales@ato.com, service@ato.com
Two questions
4
Ivank
Avatar
3/11/2026 12:28 AM
I need an ATO-LCC-DYMH-103 load cell and have two questions. First, what are the accurate reading resolutions (accuracy) of the 1 kg and 2.5 kg load cells? Second, what type of cable does the load cell come with? We need a specific type of cable connection (avionics interface).
Was this review helpful? Yes No (0/0)
ATO Responded
This load cell has a default lead output of 2 meters. Do you want to configure it with an aviation connector cable? What is the required cable length? The sensor's accuracy is 0.3%F.S.
Cable diameter
5
George
Avatar
4/10/2026 3:05 AM
What is the diameter of the cable connected to the ATO-LC-TC01 (5kg)? I am threading the cable through a cable connector.
Was this review helpful? Yes No (0/0)
ATO Responded
The wire diameter for this load-cel unit ATO-LC-TC01 (5kg) is φ3*2mm.
Fatigue Testing
5
Harpern
Avatar
4/16/2026 12:06 AM
Hello, I am very interested in purchasing the ATO-LCC-DYMH-103 load cell. Can this load cell undergo fatigue testing? If so, what is its maximum loading frequency? Thank you!
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, we do not recommend fatigue testing.
Question
5
Julia
Avatar
5/23/2026 12:34 PM
What is the diameter of the cable connected to the ATO-LC-TC01 (100kg)?
Was this review helpful? Yes No (0/0)
ATO Responded
It is a 3mm multi-core cable.
Question
5
Julia
Avatar
5/28/2026 10:22 PM
What is the grade of the threaded stud?
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, for more information, please contact our sales team: sales@ato.com, service@ato.com. We will provide you with detailed answers.
Some Questions
4
Kurtes
Avatar
10/29/2026 8:59 PM
Hello, I intend to purchase a miniature tension/compression sensor with a 1 kg range. I plan to use it for low-force mechanical testing in the tensile and compressive directions (approximately 0.1 to 10 N). Could you please confirm whether the sensor's overall accuracy (approximately 0.03 N) at 0.3% F.S. (full scale) is applicable at a 1 kg range? Additionally, could you provide specific parameter values for nonlinearity, hysteresis, repeatability, creep, and safe overload at this range?
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-LC-TC01 model has an overall accuracy of 0.3% F.S. (approximately 0.03 N) at a 1 kg range. The safe overload is 150% F.S. (1.5 kg), and the overload limit is 200% F.S. (2 kg). Linearity, hysteresis, and repeatability parameters can be found in the product manual on the website: https://www.ato.com/Content/doc/Load-cell-catalog.pdf
Only registered users can write reviews
Customers who bought this item also bought

Load Cell Transmitter, Output 0-5V/0-10V/4-20mA

ATO-LCTR-OA
$81.27
Load cell transmitter is made of aluminum alloy, output standard signal 0-5V/0-10V/4-20mA, has linear compensation, humidity compensation, external zero debugging, external span debugging, input overload protection and output short circuit protection functions.

Digital Load Cell Amplifier, Output 4-20mA/0-10V/RS485

ATO-LCTR-OAR
$109.85
High precision load cell amplifier has a 6 digit LED display, output signal 4-20mA/ 0-5V/ 0-10V/ RS485. There are 3 keys for parameter settings. Digital load cell amplifier can be calibrated on-line by its 3 keys. The setting parameters include zero, capacity, communication rate, division value, decimal digits, etc.

Load Cell Junction Box for Scales, 2/3/4/6/8/10 Inlets to 1 Outlet

ATO-LCBOX-10I
$66.67
Multi-channel load cell junction box has 2/3/4/6/8/10 inlets and 1 outlet, aluminum alloy casing, good anti-interference, special for waterproof sealing joint, waterproof and dustproof rubber gasket for cover, easy to assemble and debug. Each channel can be adjusted balance to prevent damage to the sensor caused by inductive lightning and surge signals.

Strain Gauge Load Cell, S type, 5kg/50kg/1000kg/3 ton to 20 ton

ATO-LC-S01
$88.41
S type load cell can bear both tension and pressure, with good output symmetry, high accuracy, compact structure and complete specifications. Strain gauge load cell can be applied for batching scale, electronic-mechanical scale, crane scales and other force value measurement and control.

5 Digit Display Controller for Load Cells

ATO-DPM-LC5D
$210.80
Digital panel meter can cooperate with load cells, force sensors and weighing sensors, two outputs for data comparison, digital panel meter can display gross, net, peak and valley value alternately.