Dew Point Sensor

A dew point sensor is an instrument used to measure the temperature at which moisture condenses from air or gas. It helps monitor moisture levels in compressed air systems, industrial gases, and drying processes to prevent corrosion, contamination, and equipment failure. ATO dew point sensors and transmitters provide accurate moisture measurement with 4–20mA, 0–10V, and RS485 outputs for reliable industrial monitoring and automation.

Why Use a Dew Point Sensor?

Excess moisture in compressed air and industrial gas systems can lead to condensation, corrosion, equipment failure, and reduced product quality. A dew point sensor continuously monitors moisture levels by measuring dew point temperature, helping industries maintain dry operating conditions and improve process reliability.

By providing real-time moisture data, dew point sensors help to:

  • Prevent condensation and corrosion in compressed air pipelines
  • Protect pneumatic tools, valves, and production equipment
  • Maintain product quality in moisture-sensitive processes
  • Improve dryer efficiency and energy utilization
  • Reduce maintenance costs and unexpected downtime
  • Support reliable process control and quality management

How Does a Dew Point Sensor Work?

A dew point sensor works by detecting water vapor in a gas stream and converting moisture measurements into a dew point temperature value. The sensor uses a specialized sensing element and signal processing technology to provide accurate moisture monitoring for industrial automation and process control systems.

The measurement process typically includes:

  • Moisture Sensing: The sensing element detects water vapor changes in the gas stream using technologies such as capacitive polymer, chilled mirror, or impedance measurement.
  • Signal Processing: The internal electronics process the sensor signal, compensate for temperature variations, and calculate the dew point temperature with high accuracy.
  • Data Transmission: The measured dew point value is converted into standard output signals, including 4–20 mA, 0–10 V, and RS485 Modbus, for connection with controllers and monitoring systems.
  • Process Control: PLCs, SCADA systems, and industrial controllers use the data for moisture monitoring, alarm activation, dryer control, and process optimization.

What Is the Difference Between Dew Point and Humidity?

Dew point and humidity are both measurements related to moisture in the air, but they describe moisture conditions in different ways. Dew point indicates the actual moisture content by measuring the temperature at which condensation occurs, while humidity shows how much moisture is present compared with the maximum amount of moisture the air can hold at a specific temperature.

FeatureDew PointRelative Humidity (RH)
DefinitionThe temperature at which air becomes saturated and water vapor starts to condenseThe percentage of moisture in the air compared with the maximum moisture capacity at a given temperature
Measurement Unit°C Td or °F Td%RH
Temperature InfluenceLess affected by temperature changesHighly affected by temperature changes
Measurement FocusAbsolute moisture contentMoisture level relative to air capacity
Best ApplicationsCompressed air, industrial gases, dryers, moisture controlHVAC, weather monitoring, indoor comfort

What Output Does a Dew Point Sensor Provide?

A dew point sensor converts measured moisture levels into electrical signals for monitoring and control systems. Different output options allow the sensor to connect with PLCs, SCADA systems, data loggers, and industrial automation equipment.

Common dew point sensor output types include:

Output TypeDescriptionTypical Applications
4–20 mA Analog OutputProvides a stable current signal for long-distance transmission with strong resistance to electrical interferenceIndustrial PLC control, compressed air monitoring, process automation
0–10 V Analog OutputProvides a voltage signal proportional to the measured dew point valueLocal controllers, instrumentation systems
RS485 Modbus OutputEnables digital communication and multi-device networking through the Modbus RTU protocolSCADA systems, smart factories, IoT monitoring
Relay Alarm OutputProvides switching signals when moisture levels exceed preset limitsAlarm systems, dryer control, safety monitoring

When selecting a dew point sensor, choose an output type based on your existing control system. 4–20 mA and RS485 Modbus are commonly used in industrial applications because they provide reliable long-distance transmission and easy integration with automation systems.

How Do I Choose a Dew Point Sensor?

Choosing the right dew point sensor depends on your application requirements, measurement range, accuracy, output signal, and installation environment.

Selection FactorConsideration
Dew Point RangeSelect a suitable range based on your dryer type and required moisture level. Low dew point sensors are recommended for desiccant dryers and ultra-dry gas systems.
AccuracyChoose higher accuracy models for critical applications such as pharmaceuticals and semiconductor manufacturing.
Output SignalSelect 4–20 mA, 0–10 V, or RS485 Modbus according to your control system.
Operating ConditionsEnsure the sensor matches the temperature, pressure, and installation environment of your application.

What Measurement Technologies Are Used in Dew Point Sensors?

Dew point sensors use different sensing technologies to measure moisture content in air and gases. The selection of sensing technology depends on required accuracy, dew point range, response time, and application conditions. The most common technologies include capacitive, chilled mirror, and aluminum oxide sensing methods.

Sensor TypeWorking PrincipleTypical Applications
Capacitive Dew Point SensorMeasures moisture changes through variations in capacitance of a sensing filmCompressed air systems, dryers, industrial gases
Chilled Mirror Dew Point SensorDetects condensation on a cooled mirror surface for high-precision measurementCalibration, laboratories, reference measurement
Aluminum Oxide Dew Point SensorMeasures moisture through changes in electrical impedanceUltra-low dew point gases and critical processes

For most industrial moisture monitoring applications, capacitive dew point sensors are widely used due to their fast response, wide measurement range, and cost-effective performance. Chilled mirror sensors are preferred for high-accuracy reference measurements, while aluminum oxide sensors are suitable for ultra-low moisture applications.

ATO Dew Point Sensor Selection Guide

The following table compares different dew point sensors and transmitters by measurement range, accuracy, output, and typical applications to help you select the right solution.

Product TypeDew Point RangeAccuracyOutputApplication
Dew Point Sensor for Cold Dryer-30~50°C Td±2°C Td4-20mA / RS485Refrigerated dryers
Dew Point Sensor for Compressed Air-60~60°C Td±2°C Td4-20mA / RS485Compressed air systems
Dew Point Sensor for Air Dryer-60~20°C Td±2°C Td4-20mA / RS485Air dryers
Industrial Dew Point Transmitter-60~90°C Td±2°C Td4-20mA / RS485Industrial process monitoring
Dew Point Temperature Sensor-20~100°C Td±3°C Td4-20mA / RS485High-temperature applications


Why Choose Our Dew Point Sensors?

Different models are designed for various moisture monitoring requirements, from refrigerated dryers and compressed air systems to industrial processes and high-temperature applications.

Key advantages include:

  • Wide Dew Point Measurement Range: Supports different moisture monitoring needs from standard compressed air systems to ultra-dry applications.
  • Multiple Output Options: Available with 4–20mA, 0–10V, and RS485 communication for easy integration with PLC and industrial control systems.
  • High Measurement Accuracy: Provides reliable dew point monitoring with accuracy up to ±2°C Td for demanding industrial applications.
  • Designed for Different Applications: Models are available for cold dryers, compressed air systems, air dryers, and high-temperature processes.
  • Stable Industrial Performance: Designed for continuous operation with reliable moisture measurement and long-term stability.
View as Grid List
Sort by
Display per page

Dew Point Sensor for Cold Dryer, -30~50°C, RS485&4-20mA

ATO-DPS-HG602C
$592.21
Dew point sensor for cold dryer delivers reliable moisture monitoring for compressed air systems, providing dual RS485 and 4-20mA outputs. With high-pressure resistance and minimal power consumption, this online dew point transmitter measures from -30 to 50°C with ±2°C accuracy, and features anti-condensation heating for harsh environments, ensuring accurate dew point tracking in industrial applications.

Dew Point Sensor for Compressed Air, -60~60°C, RS485&4-20mA

ATO-DPS-HG602D
$709.85
Maintain optimal compressed air quality with ATO -60~60°C dew point monitoring. The dew point sensor for compressed air delivers ±2°C Td accuracy and features anti-condensation heating for challenging environments, offering simultaneous RS485 & 4-20mA outputs for flexible system integration. With 16-bar pressure resistance and low power consumption under 0.1W, continuous dew point monitor ensures stable performance in refrigerated and desiccant dryer applications.

Dew Point Sensor for Air Dryer, -60~+20°C, 4-20mA/RS485

ATO-DPS-HDP6206
$539.26
Buy ATO dew point sensor for air dryer to optimize air dryer performance. This industrial dew point transmitter offers a measurement range of -60 to +20°C with ±2°C Td accuracy. Designed for harsh conditions, the sensor features stainless steel housing and IP65 protection. Dual 4-20mA and RS485 outputs enable seamless industrial integration.

Industrial digital Dew Point Transmitter, -60~90°C, Online Type

ATO-DPS-HG808D
$1,068.68
The industrial digital dew point transmitter provides reliable -60~90°C monitoring for industrial process control. This online type sensor delivers ±2°C Td accuracy with excellent long-term stability. Flexible RS485 and analog outputs support various control system integrations. Factory-calibrated dew point temperature transmitter offers dependable operation for compressed air systems and industrial gas processing applications.

Dew Point Temperature Sensor, -20~100°C Dewpoint, 80~180°C Temp

ATO-DPS-HG808A
$1,068.68
The dew point temperature sensor delivers reliable -20~100°C dewpoint monitoring for high-temperature processes operating at 80~180°C ambient. Ensuring real-time moisture tracking in demanding industrial applications including thermal processing and compressed air systems, this continuous dew point monitor maintains ±3°C Td accuracy with excellent long-term stability below 0.1°C/year. Robust dew point transmitter construction withstands 16-bar pressure environments while providing flexible RS485 and analog outputs.

Dew Point Sensor