Ultrasonic Water Flow Meter, Wall Mounted

$886.98
Wall mounted ultrasonic flow meter ranging from DN25 to DN600mm, with ultra large scale integrated circuit design, low hardware count, low voltage operation and multiple pulse emission. The Wall mounted ultrasonic flow meter is compatible with 4-20mA/OTC pulses, RS485 communication, IP65 protection class allows the flowmeter to be used in harsh field environments for long periods of time.
SKU: ATO-FLOW-WM
*
Free Shipping
Delivery date: 6-12 days

The wall mounted ultrasonic flow meter is designed to measure the flow of liquids in various closed pipes, measuring range from DN25 to DN600 mm, with instantaneous and totalised values displayed in real time, compatible with 4-20mA/OTC pulses, RS485 communication, etc. The optimised intelligent signal adaption allows the user to use the meter without any circuit adjustments, just as easy as using a multimeter.

Specification

ModelATO-SUP-1158S
Measurement Accuracy0.01~5.0m/s (0.03~16ft/s)
Accuracy ClassGrade 1
Pipe Diameter Range25mm~600mm (1° ~24* )
Measuring MediumWater, oil and other single medium liquid
Pipe MaterialCarbon steel, stainless steel, PVC
OutputOCT pulse output: 0-5000Hz
Analog Output4~20mA, maximum load resistance 7500
Communication InterfaceRS485 communication interface supports MODBUS protocol
Power Supply10~36VDC/1A
Transmitter Installation Environment Temperature-10℃ ~ 50℃
Special Sensor Measurement Medium Temperature0℃~ 80℃
Transmitter MaterialPC / ABS plastic housing
Protection ClassIP65
Sensor MaterialSealed design, protection class IP68
Standard Cable Length9m (30ft)
Transmitter Weight0.7kg
Sensor Weight0.4kg


Transducer Selection

TransducerMeasuring Pipe Size RangeTemperature RangeDimensions (mm)
Standard clamp-on transducer - SmallDN32-DN100-40℃~90℃45*25*32
Standard clamp-on transducer - MediumDN50-DN70064*39*44
Standard clamp-on transducer - LargeDN300-DN600097*54*33
High-temp clamp-on transducer - SmallDN32-DN100-30℃~160℃45*25*32
High-temp clamp-on transducer - MediumDN50-DN70064*39*44
High-temp clamp-on transducer - LargeDN300-DN600097*54*33


Feature

  1. Host Upgrade: 2-in-1 volume is more compact, easier to use and carry.
  2. Probe Upgrade: Transmitter power is strengthened, only one kind of probe is needed, easy to realize DN25-1200 caliber pipeline flow measurement Protection level is upgraded to IP68, which can resist water immersion.
  3. Signal Upgrade: Standard 4-20mA output, support standard 485 communication standard, 10-36V instrument wide voltage supply.
  4. Installation Upgrade: Alternative to the traditional pipeline installation flowmeter, without the need to stop the flow of broken pipe, pipe wall a paste to easily realize the flow measurement.

Dimension (unit: mm)

Wall-mounted ultrasonic flow meter size

Detail

Wall-mounted ultrasonic flow meter detail

Transducer Installation

1. Choosing right installation position

Ultrasonic flow meter transducer installing position

  • The pipeline where the transducer is installed must have a long enough straight pipe section, of course, the longer the better, generally 10 times the pipe diameter upstream, 5 times the pipe diameter downstream, and 30 times the pipe diameter from the pump port. At the same time, ensure that the liquid in this section must be full.
  • Make sure that the temperature range of the pipe under test is within the applicable range of the sensor, usually at room temperature.
  • Take the corrosion or scaling of the pipeline into consideration. It is better to choose a newer pipeline for the measurement. If it is not available, subtract the corrosion from the pipe wall thickness or consider scaling as the pipe lining.

2. Transducer installation method

  • Z-installation method: generally suitable for the pipes above DN100mm

Ultrasonic flow meter transducer Z installation

  • V-installation method: generally suitable for the DN20-300mm pipes

Ultrasonic flow meter transducer V installation.

  • W-installation method: usually used for pipes of DN10- 100mm pipes

Ultrasonic flow meter transducer W installation

* The installation distance is shown after entering the pipe parameters into the ultrasonic flow meter.


Applications

Wall-mounted ultrasonic flow meter applications

Tips: What are the advantages of Wall mounted ultrasonic flow meter?

  • Real-time display of instantaneous and accumulated values
  • Compatible with 4-20mA/OTC pulse, RS485 communication, and other functions.
  • IP65 protection rating for long-term use in harsh field environments.
  • Low hardware count, low voltage operation, multi-pulse emission, low power consumption, and high reliability.

How to Set the Parameters of the Wall Mounted Ultrasonic Flow Meter for Water?

When using the flow meter, you need to set the parameters of the pipeline. In this video, the steps for setting the pipeline are shown.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The wall mounted ultrasonic flow meter is designed to measure the flow of liquids in various closed pipes, measuring range from DN25 to DN600 mm, with instantaneous and totalised values displayed in real time, compatible with 4-20mA/OTC pulses, RS485 communication, etc. The optimised intelligent signal adaption allows the user to use the meter without any circuit adjustments, just as easy as using a multimeter.

Specification

ModelATO-SUP-1158S
Measurement Accuracy0.01~5.0m/s (0.03~16ft/s)
Accuracy ClassGrade 1
Pipe Diameter Range25mm~600mm (1° ~24* )
Measuring MediumWater, oil and other single medium liquid
Pipe MaterialCarbon steel, stainless steel, PVC
OutputOCT pulse output: 0-5000Hz
Analog Output4~20mA, maximum load resistance 7500
Communication InterfaceRS485 communication interface supports MODBUS protocol
Power Supply10~36VDC/1A
Transmitter Installation Environment Temperature-10℃ ~ 50℃
Special Sensor Measurement Medium Temperature0℃~ 80℃
Transmitter MaterialPC / ABS plastic housing
Protection ClassIP65
Sensor MaterialSealed design, protection class IP68
Standard Cable Length9m (30ft)
Transmitter Weight0.7kg
Sensor Weight0.4kg


Transducer Selection

TransducerMeasuring Pipe Size RangeTemperature RangeDimensions (mm)
Standard clamp-on transducer - SmallDN32-DN100-40℃~90℃45*25*32
Standard clamp-on transducer - MediumDN50-DN70064*39*44
Standard clamp-on transducer - LargeDN300-DN600097*54*33
High-temp clamp-on transducer - SmallDN32-DN100-30℃~160℃45*25*32
High-temp clamp-on transducer - MediumDN50-DN70064*39*44
High-temp clamp-on transducer - LargeDN300-DN600097*54*33


Feature

  1. Host Upgrade: 2-in-1 volume is more compact, easier to use and carry.
  2. Probe Upgrade: Transmitter power is strengthened, only one kind of probe is needed, easy to realize DN25-1200 caliber pipeline flow measurement Protection level is upgraded to IP68, which can resist water immersion.
  3. Signal Upgrade: Standard 4-20mA output, support standard 485 communication standard, 10-36V instrument wide voltage supply.
  4. Installation Upgrade: Alternative to the traditional pipeline installation flowmeter, without the need to stop the flow of broken pipe, pipe wall a paste to easily realize the flow measurement.

Dimension (unit: mm)

Wall-mounted ultrasonic flow meter size

Detail

Wall-mounted ultrasonic flow meter detail

Transducer Installation

1. Choosing right installation position

Ultrasonic flow meter transducer installing position

  • The pipeline where the transducer is installed must have a long enough straight pipe section, of course, the longer the better, generally 10 times the pipe diameter upstream, 5 times the pipe diameter downstream, and 30 times the pipe diameter from the pump port. At the same time, ensure that the liquid in this section must be full.
  • Make sure that the temperature range of the pipe under test is within the applicable range of the sensor, usually at room temperature.
  • Take the corrosion or scaling of the pipeline into consideration. It is better to choose a newer pipeline for the measurement. If it is not available, subtract the corrosion from the pipe wall thickness or consider scaling as the pipe lining.

2. Transducer installation method

  • Z-installation method: generally suitable for the pipes above DN100mm

Ultrasonic flow meter transducer Z installation

  • V-installation method: generally suitable for the DN20-300mm pipes

Ultrasonic flow meter transducer V installation.

  • W-installation method: usually used for pipes of DN10- 100mm pipes

Ultrasonic flow meter transducer W installation

* The installation distance is shown after entering the pipe parameters into the ultrasonic flow meter.


Applications

Wall-mounted ultrasonic flow meter applications

Tips: What are the advantages of Wall mounted ultrasonic flow meter?

  • Real-time display of instantaneous and accumulated values
  • Compatible with 4-20mA/OTC pulse, RS485 communication, and other functions.
  • IP65 protection rating for long-term use in harsh field environments.
  • Low hardware count, low voltage operation, multi-pulse emission, low power consumption, and high reliability.
Only registered users can write reviews