Portable Nitric Oxide (NO) Gas Detector, 0 to 20/50/100 ppm

$846.29
Favorable price Nitric Oxide (NO) Gas Detector for sale. Optional measuring range 0 to 20/50/100/250 ppm, light weight and compact size, portable and convenient to transport. Give sound, light and vibration alarm for NO gas leak, fast response and accurate detection.
SKU: GD200-NO
*
*
*
Free Shipping
Delivery date: 6-12 days

Portable Nitric Oxide (NO) gas leak detector draws the gas by built-in micro pump and comes in the measuring range 0 to 20/50/100 ppm for choice, fast response, precision measurement and affordable price.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof

Specification

ModelGD200-NO
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasNitric Oxide (NO)
Range (Optional) *0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 250ppm, 0 to 500ppm, 0 to 1000ppm
Resolution0.01ppm (0-20/50ppm), 0.1ppm (0-100/250ppm), 1ppm (0-500ppm/1000ppm)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note 1:

  • If you require an XX gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Portable Nitric Oxide (NO) Gas Detector Details

Applications

The NO gas detector is used to detect the nitric oxide gas leak, suitable for petroleum, chemical, coal, metallurgy, pharmaceutical and other places involving hazardous gases such as nitric oxide.

NO Gas Detector Applications

Tips:

Nitric oxide (NO) is a kind of colorless, odorless, toxic gas that is insoluble in water. Since nitric oxide contains free radicals, this makes its chemical properties very active. When it reacts with oxygen, it can form a corrosive gas-nitrogen dioxide (NO2) that can react with water to form nitric acid. In industrial production, boiler exhaust gas, pipeline desulfurization and denitrification waste gas, and the plant environment are need to be monitored where there is NO leakage in real time. It is also needed for the environmental protection bureau to real-time monitor the enterprise nitric oxide gas emissions. At this time, it is very meaningful to use an industrial nitric oxide gas detector to monitor nitric oxide (NO).

The nitric oxide (NO) detector can be a single gas detector or multi-gas detector which is also equipped with other gas sensor like oxygen sensor, LEL sensor and so on, to detect the concentration of NO in the air. It is selected according to the actual requirements.

ATO portable nitric oxide gas detector adopts a pumping sampling method and uses a high-precision electrochemical sensor with excellent sensitivity and high repeatability. With on-site sound and light alarm function, the detector will give an instant alarm when the gas concentration exceeds the standard value, safeguard the workers at dangerous field operations.

Basic Settings of Portable Gas Detector

This video will show you the basic settings of ATO portable gas detectors including high/low alarm setting, language setting and time setting.

Calibration of Portable Gas Detector

This video will show how to calibrate the ATO portable gas detectors.

Concentration Detection of Pesticides Gas

Methyl bromide is an organic compound with the chemical formula CH3Br, which is mainly used as a pesticide, fumigant, refrigerant and solvent, and can also be used in organic synthesis.This video will mainly use methyl bromide and CH3Br as examples to introduce the detection of their concentrations.

How to Detect Hydrogen Sulfide Concentration in the Toilet

Hydrogen sulfide is a flammable acidic gas that smells like rotten eggs at low concentrations and is very toxic. In actual operation, it is necessary to ensure that the detection equipment or method used can accurately measure the concentration of hydrogen sulfide, and pay attention to safety issues during operation to avoid hydrogen sulfide poisoning.

How much C2H4 (ethylene) do ripe bananas and apples produce?

We have various gas detectors such as: CO, O2, O3, H2, NH3, H2S, CH4, Cl2, CH2O, etc, from 0~10000ppm, Industrial or daily use.

How Does a Portable Detector Work?

This video explains how a portable detector works and uses it to measure the air around you.

Portable Single Gas Detector Parameter Settings

In this video, we show you the menu settings of the ATO portable detector. Five button operation makes it very simple to control and activate functions. This device provides two alarm types, high alarm point and low alarm point, which can be adjusted as needed. The speed of the pump is also allowed to be adjusted. Calibration options include zero calibration and span calibration, both of which should be performed by qualified professionals under strict operating conditions using necessary accessories and standard gases.

How to Calibrate a Portable Gas Detector?

This video shows how to calibrate a portable gas detector. The ATO portable gas detector is lithium battery powered, has data logging capabilities and is available with a calibration kit.

Gas Detector Detection Range Setting

This video demonstrates the detection range setting of a portable gas detector.

Product reviews
The role of nitric oxide gas detector
5
Paschak
Avatar
11/8/2021 7:25 PM
Can I use your NO gas detector to check for ultra-high purity nitric oxide leakage?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, NO gas detector can detect ultra-high purity nitric oxide leakage, the detection range is 0-100% VOL.
Small and easy to carry
5
Colleen
Avatar
8/3/2022 12:26 AM
This NO gas detector is small and easy to carry. The concentrations detected are also accurate. It's the one I've been looking for. Highly recommended!!!
Was this review helpful? Yes No (0/0)
What volume of gas is required to obtain an accurate reading?
5
Rachel
Avatar
9/9/2022 3:02 AM
How much gas must be used to get a precise reading?
What volume bag would this device need to be connected to in order for it to provide an accurate reading if, for instance, I collected gas from various locations in Tedlar bags (which have the same internal pressure as room air pressure), stored them, and then wanted to read the contents of each bag on this pump-type sensor?
Was this review helpful? Yes No (0/0)
ATO Responded
The volume of the bag shouldn't be too small if the gas detector needs to measure food packaging bags in order to prevent the bag from being easily sucked dry.
You can look at the attached demo case to get the bag's measurements. The bag's volume and dimensions should roughly match those of the box in the video.
One more thing: the additional probe required by the gas detector used to test the gas in the bag must be specified when ordering.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Portable Nitric Oxide (NO) gas leak detector draws the gas by built-in micro pump and comes in the measuring range 0 to 20/50/100 ppm for choice, fast response, precision measurement and affordable price.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof

Specification

ModelGD200-NO
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasNitric Oxide (NO)
Range (Optional) *0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 250ppm, 0 to 500ppm, 0 to 1000ppm
Resolution0.01ppm (0-20/50ppm), 0.1ppm (0-100/250ppm), 1ppm (0-500ppm/1000ppm)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note 1:

  • If you require an XX gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Portable Nitric Oxide (NO) Gas Detector Details

Applications

The NO gas detector is used to detect the nitric oxide gas leak, suitable for petroleum, chemical, coal, metallurgy, pharmaceutical and other places involving hazardous gases such as nitric oxide.

NO Gas Detector Applications

Tips:

Nitric oxide (NO) is a kind of colorless, odorless, toxic gas that is insoluble in water. Since nitric oxide contains free radicals, this makes its chemical properties very active. When it reacts with oxygen, it can form a corrosive gas-nitrogen dioxide (NO2) that can react with water to form nitric acid. In industrial production, boiler exhaust gas, pipeline desulfurization and denitrification waste gas, and the plant environment are need to be monitored where there is NO leakage in real time. It is also needed for the environmental protection bureau to real-time monitor the enterprise nitric oxide gas emissions. At this time, it is very meaningful to use an industrial nitric oxide gas detector to monitor nitric oxide (NO).

The nitric oxide (NO) detector can be a single gas detector or multi-gas detector which is also equipped with other gas sensor like oxygen sensor, LEL sensor and so on, to detect the concentration of NO in the air. It is selected according to the actual requirements.

ATO portable nitric oxide gas detector adopts a pumping sampling method and uses a high-precision electrochemical sensor with excellent sensitivity and high repeatability. With on-site sound and light alarm function, the detector will give an instant alarm when the gas concentration exceeds the standard value, safeguard the workers at dangerous field operations.

Product reviews
The role of nitric oxide gas detector
5
Paschak
Avatar
11/8/2021 7:25 PM
Can I use your NO gas detector to check for ultra-high purity nitric oxide leakage?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, NO gas detector can detect ultra-high purity nitric oxide leakage, the detection range is 0-100% VOL.
Small and easy to carry
5
Colleen
Avatar
8/3/2022 12:26 AM
This NO gas detector is small and easy to carry. The concentrations detected are also accurate. It's the one I've been looking for. Highly recommended!!!
Was this review helpful? Yes No (0/0)
What volume of gas is required to obtain an accurate reading?
5
Rachel
Avatar
9/9/2022 3:02 AM
How much gas must be used to get a precise reading?
What volume bag would this device need to be connected to in order for it to provide an accurate reading if, for instance, I collected gas from various locations in Tedlar bags (which have the same internal pressure as room air pressure), stored them, and then wanted to read the contents of each bag on this pump-type sensor?
Was this review helpful? Yes No (0/0)
ATO Responded
The volume of the bag shouldn't be too small if the gas detector needs to measure food packaging bags in order to prevent the bag from being easily sucked dry.
You can look at the attached demo case to get the bag's measurements. The bag's volume and dimensions should roughly match those of the box in the video.
One more thing: the additional probe required by the gas detector used to test the gas in the bag must be specified when ordering.
Only registered users can write reviews
Customers who bought this item also bought

Portable Ozone (O3) Gas Detector, 0 to 10/20/50 ppm

GD200-O3
$815.39
Portable Ozone gas detector, applied for the O3 gas detection with high accuracy and fast response, measuring range from 0 to 10ppm / 20ppm / 50ppm for options, real-time LCD display, give sound, light & vibrating alarm, small & light O3 detector at affordable price, handheld design, convenient to carry around.