Oxygen Gas Sensor/Transmitter, RS485/4-20mA/0-5V

$101.58
The oxygen gas sensor measures ranges of 0-30%VOL for RS485 output and 0-25%VOL for analog output, with an accuracy of ±3%FS and a resolution of 0.1%VOL. Gas transmitter has a power supply range of 10~30V DC, with the 0~10V output type requiring a 24V supply. Widely used in industries such as process control, environmental monitoring, medical devices, food and beverage, safety detection, scientific research, and combustion system optimization.
SKU: ATO-GS-O2-3002
*
*
Free Shipping
Delivery date: 6-12 days

The oxygen gas sensor measures 0-30%VOL (RS485) and 0-25%VOL (analog) with ±3%FS accuracy and 0.1%VOL resolution. It operates on 10~30V DC, requiring 24V for 0~10V output, and is widely used in process control, environmental monitoring, healthcare, and safety applications.

Specification

ModelATO-VMS-3002-O2-*
Power Supply10~30V DC (0~10V output type requires 24V supply)
Output Signal4-20mA, 0-5V, 0-10V (optional)
Power ConsumptionRS485: 0.12W; 4-20mA, 0-5V, 0-10V: 0.25W
Operating Temperature-20~50°C
Operating Humidity5~95%RH, non-condensing
Pressure Range90~110kPa
Stability≤5% signal value/year
Response Time≤10s
Preheating Time≥5 minutes
Zero Drift (-20~40°C)±0.3%VOL
Repeatability≤1%
Service Life≥24 months
Measurement RangeRS485: 030%VOL; Analog: 025%VOL
Accuracy±3%FS
Resolution0.1%VOL


Feature

  • High Protection and Durable Exterior: Made with high-density materials and equipped with waterproof seals to provide moisture and dust resistance, ensuring reliable operation in harsh environments.
  • Standard ModBus-RTU Communication Protocol: Supports RS485 communication interface with configurable communication addresses and baud rates. It offers a maximum communication distance of up to 2000 meters, ideal for remote monitoring applications.
  • High Efficiency and Sensitivity: Equipped with a highly sensitive gas detection sensor that delivers stable signals and high precision, ensuring real-time and accurate oxygen monitoring.
  • Wide Application Environments: Suitable for use in factories, warehouses, food storage facilities, farms, orchards, and forestry applications, meeting both industrial and agricultural oxygen detection needs.

Size (Unit:mm)

O2 transmitter size

Wiring Instructions

RS485

Wide voltage power supply input 10~30V is available. 485 signal line wiring, pay attention to the A\B two lines can not be reversed, the address of multiple devices on the bus can not conflict.

O2 transmitter wiring diagram

Wire ColorDescription
PowerBrownPower Positive
BlackPower Negative
CommunicationYellowRS485-A
BlueRS485-B

4-20mA/0-5V

Wide voltage 10~30V DC power input. For 0-10V output type devices only 24V power supply can be used.

Wire ColorDescription
PowerBrownPower Positive
BlackPower Negative
Output SignalYellowSignal Positive
BlueSignal Negative


Application

O2 transmitter application

Tips: What kind of maintenance does the sensor require?

To ensure long-term performance and accuracy, the sensor requires minimal but regular maintenance, which includes:

  • Periodic calibration: Calibration every 6-12 months to correct signal drift and maintain accuracy.
  • Cleaning: Gently clean the exterior to remove dust, moisture, or contaminants. Ensure the waterproof and dustproof seals remain intact.
  • Inspection: Regularly check for signs of wear, damage, or unusual readings. Address issues promptly to avoid sensor failure.
  • System check: For RS485 communication, confirm that the wiring, connections, and data transmission remain stable over time.
Product reviews
0-5V Sensor
5
Enres
Avatar
9/4/2025 9:54 PM
Unfortunately, we're looking for a sensor with a 0-5V output, but the SKU: GD300-O2 doesn't seem to have this option. For the SKU: ATO-OS-3002O2, what's the temperature of the heating element? Will the sensor still output readings during the 5-minute warm-up period?
Was this review helpful? Yes No (0/0)
ATO Responded
This sensor (SKU: ATO-OS-3002O2) will only output accurate data after the 5-minute warm-up period. While it will output data during the 5-minute warm-up period, the values may be inaccurate.
Application in oxygen detection
5
Zinia
Avatar
12/16/2025 8:24 PM
Hello, I am interested in the device with product number ATO-GS-O2-3002. We plan to use it in a copper leaching process, requiring hourly oxygen concentration measurements. We have designed a system where gas samples are collected through a T-connector, and the gas flows upwards driven by a pump. Is this sensor suitable for this application? We are concerned that the pump might interfere with gas sampling or affect the sensor's measurement accuracy.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, we haven't tested it and are unsure if it's suitable for your application. You can purchase one to test.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The oxygen gas sensor measures 0-30%VOL (RS485) and 0-25%VOL (analog) with ±3%FS accuracy and 0.1%VOL resolution. It operates on 10~30V DC, requiring 24V for 0~10V output, and is widely used in process control, environmental monitoring, healthcare, and safety applications.

Specification

ModelATO-VMS-3002-O2-*
Power Supply10~30V DC (0~10V output type requires 24V supply)
Output Signal4-20mA, 0-5V, 0-10V (optional)
Power ConsumptionRS485: 0.12W; 4-20mA, 0-5V, 0-10V: 0.25W
Operating Temperature-20~50°C
Operating Humidity5~95%RH, non-condensing
Pressure Range90~110kPa
Stability≤5% signal value/year
Response Time≤10s
Preheating Time≥5 minutes
Zero Drift (-20~40°C)±0.3%VOL
Repeatability≤1%
Service Life≥24 months
Measurement RangeRS485: 030%VOL; Analog: 025%VOL
Accuracy±3%FS
Resolution0.1%VOL


Feature

  • High Protection and Durable Exterior: Made with high-density materials and equipped with waterproof seals to provide moisture and dust resistance, ensuring reliable operation in harsh environments.
  • Standard ModBus-RTU Communication Protocol: Supports RS485 communication interface with configurable communication addresses and baud rates. It offers a maximum communication distance of up to 2000 meters, ideal for remote monitoring applications.
  • High Efficiency and Sensitivity: Equipped with a highly sensitive gas detection sensor that delivers stable signals and high precision, ensuring real-time and accurate oxygen monitoring.
  • Wide Application Environments: Suitable for use in factories, warehouses, food storage facilities, farms, orchards, and forestry applications, meeting both industrial and agricultural oxygen detection needs.

Size (Unit:mm)

O2 transmitter size

Wiring Instructions

RS485

Wide voltage power supply input 10~30V is available. 485 signal line wiring, pay attention to the A\B two lines can not be reversed, the address of multiple devices on the bus can not conflict.

O2 transmitter wiring diagram

Wire ColorDescription
PowerBrownPower Positive
BlackPower Negative
CommunicationYellowRS485-A
BlueRS485-B

4-20mA/0-5V

Wide voltage 10~30V DC power input. For 0-10V output type devices only 24V power supply can be used.

Wire ColorDescription
PowerBrownPower Positive
BlackPower Negative
Output SignalYellowSignal Positive
BlueSignal Negative


Application

O2 transmitter application

Tips: What kind of maintenance does the sensor require?

To ensure long-term performance and accuracy, the sensor requires minimal but regular maintenance, which includes:

  • Periodic calibration: Calibration every 6-12 months to correct signal drift and maintain accuracy.
  • Cleaning: Gently clean the exterior to remove dust, moisture, or contaminants. Ensure the waterproof and dustproof seals remain intact.
  • Inspection: Regularly check for signs of wear, damage, or unusual readings. Address issues promptly to avoid sensor failure.
  • System check: For RS485 communication, confirm that the wiring, connections, and data transmission remain stable over time.
Product reviews
0-5V Sensor
5
Enres
Avatar
9/4/2025 9:54 PM
Unfortunately, we're looking for a sensor with a 0-5V output, but the SKU: GD300-O2 doesn't seem to have this option. For the SKU: ATO-OS-3002O2, what's the temperature of the heating element? Will the sensor still output readings during the 5-minute warm-up period?
Was this review helpful? Yes No (0/0)
ATO Responded
This sensor (SKU: ATO-OS-3002O2) will only output accurate data after the 5-minute warm-up period. While it will output data during the 5-minute warm-up period, the values may be inaccurate.
Application in oxygen detection
5
Zinia
Avatar
12/16/2025 8:24 PM
Hello, I am interested in the device with product number ATO-GS-O2-3002. We plan to use it in a copper leaching process, requiring hourly oxygen concentration measurements. We have designed a system where gas samples are collected through a T-connector, and the gas flows upwards driven by a pump. Is this sensor suitable for this application? We are concerned that the pump might interfere with gas sampling or affect the sensor's measurement accuracy.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, we haven't tested it and are unsure if it's suitable for your application. You can purchase one to test.
Only registered users can write reviews
Customers who bought this item also bought

Noise Sensor, 0-5V, 0-10V, 4-20mA

ATO-YS1920
$127.46
With a compact design measuring 110mm in length and 20mm in diameter, featuring versatile output options of 0-5V, and 4-20mA, covering frequencies from 31.5Hz to 8kHz, noise sensor captures a broad spectrum of sound.

Industrial Vibration Sensor, RS485/4-20mA/0-5V/0-10V

ATO-VT-N01
$139.66
Good quality industrial vibration sensors for sale support RS485/4-20mA/0-5V/0-10V and other transmission modes to meet different site monitoring needs. This vibration transmitter can detect 10-1600Hz/10-5000Hz frequency range of uniaxial/triaxial vibration displacement, suitable for all kinds of motors, fans, pumps, machine tools and other equipment vibration testing and fault reduction.

Pressure Sensor for Air/Water/Oil, 4-20mA/RS485/0-5V/0-10V Output

ATO-PRES-P300S
$119.68
Low-range pressure sensor provides 0–10/20/50/100 kPa, -100–0 kPa and -100–100 kPa options with current, voltage or RS485 outputs. Designed for low-pressure and vacuum/compound pressure measurement of air, water and oil, with flexible 12V, 24V or 12–36V DC power supply.

Medical Oxygen Sensor, Lead-free, 0-100% Linear

ATO-GS-O2-3100
$104.46
Factory price medical oxygen sensor is for sale. It is based on the voltage divider electrochemistry principle, featuring linear measurement across the full range of 0 - 100%, a response time of less than 15 seconds, and high precision and efficiency. O2 oxygen sensor is lead-free and complies with the RoHS standard, can be widely used in medical equipment such as oxygen generators and medical ventilators.

Digital Pressure Sensor for Hydraulic/Steam/Air

ATO-PRES-PX300
$173.33
Digital pressure sensor covers -0.1 to 100 MPa and supports 4–20mA, 0–20mA, voltage and RS485 outputs, with a backlit LCD display. Suitable for hydraulic, steam, air and liquid pressure measurement, with medium temperatures from -40°C to 60°C.