Medical Oxygen Sensor, Lead-free, 0-100% Linear

$104.46
Factory price medical oxygen sensor is for sale. It is based on the voltage divider electrochemistry principle, featuring linear measurement across the full range of 0 - 100%, a response time of less than 15 seconds, and high precision and efficiency. O2 oxygen sensor is lead-free and complies with the RoHS standard, can be widely used in medical equipment such as oxygen generators and medical ventilators.
SKU: ATO-GS-O2-3100
Free Shipping
Delivery date: 6-12 days

ATO medical oxygen sensor is a full-range oxygen sensor using voltage divider electrochemistry technology. It has a measurement range of 0-100%, a response time of less than 15 seconds, and is equipped with temperature compensation (0-40℃) to ensure accurate and stable detection. Medical O2 sensor does not require an external power supply, is lead-free and environmentally friendly, and can be directly integrated into medical devices such as oxygen generators and anesthesia equipment. Meanwhile, O2 oxygen sensor's lead-free and environmentally friendly characteristics meet the demand for green products in the medical field, providing a reliable and efficient solution for oxygen concentration monitoring in medical scenarios.

Specification

ModelATO-AOX3100
Detectable Gas TypeOxygen
Working PrincipleVoltage Divider Electrochemistry
Output Voltage9-14mV (in air)
Measurement Range0-100%
Response Time (T90)<15s
LinearityFull-scale Linear
Temperature Compensation<2% O2 equivalent (0-40℃)
Load Resistance≥10kΩ
InterfaceMolex 3-pin header (2.54mm) (MOLEX 22-29-2031)
Recommended Matching InterfaceMolex wire harness (MOLEX 22-01-2035)
Molex crimp terminal (MOLEX 08-45-0110)
Housing MaterialWhite HDPE
Weight30g
Operating Temperature Range0-50℃
Recommended Storage Temperature5-15℃
Operating Pressure Range0.5-2.0bar
Operating Humidity Range0-99% RH (no condensation)
Long-term Drift in 100% O2 Environment<5% (voltage decay/year)
Expected Service Life24 months
Warranty Period12 months


Features

Measurement Performance: 0-100% full-scale linear measurement with response time <15s, output voltage 9-14mV (in air), and temperature compensation <2% O2 equivalent (0-40℃), ensuring high accuracy and stability.
Convenience & Integration: No external power supply required, comes with Molex 3-pin interface (2.54mm) and recommended matching wire harness and crimp terminal for easy integration.
Environmental & Durability: Medical oxygen sensor is lead-free and RoHS compliant, with white HDPE housing. It has an expected service life of 24 months, a warranty period of 12 months, and can operate in a temperature range of 0-50℃, humidity range of 0-99% RH (no condensation), and pressure range of 0.5-2.0bar.
Application: O2 sensor is suitable for medical devices such as oxygen concentrator control devices, medical ventilators, anesthesia equipment, as well as incubators and other scenarios requiring oxygen concentration monitoring, also performs excellently in the automobile, fire-fighting, and coal mining industries.

Pin Definition

Medical O2 sensor pin definition

Dimension (Unit: mm)

Medical O2 sensor dimension

Application

Medical O2 sensor appliation

Tips: How Does Response Time Affect Performance of Oxygen Sensor in Medical Industry?

Among the core performance indicators of medical devices, "response time" is a key parameter for evaluating the suitability of oxygen sensors in clinical scenarios, directly related to the accuracy and timeliness of medical monitoring. The T₉₀ response time is even recognized as the industry's core evaluation standard. Simply put, the T90 response time refers to the time required for an oxygen sensor to stabilize its output signal to 90% of the final target value after coming into contact with the target oxygen concentration environment. The value directly reflects the sensor's "perceptual sensitivity" to changes in oxygen concentration — the smaller the value, the faster the sensor's reaction speed, enabling it to capture concentration fluctuations and feedback valid signals in a shorter time. In the medical field, especially for life-support equipment, the T90 response time is by no means a dispensable technical parameter, but a "threshold" that determines whether a sensor meets clinical requirements, and it directly safeguards patients' lives.

ATO medical oxygen sensor is equipped with a T90 response time of <15s, demonstrating irreplaceable value in medical industry applications. Its importance and advantages are reflected in multiple core scenarios. In life-support equipment such as ventilators and anesthesia machines, the fast response of <15s can accurately adapt to the dynamic breathing needs of critically ill patients: whether it is the breathing fluctuations of patients with acute respiratory distress syndrome or changes in airway oxygen concentration during surgical anesthesia, the sensor can instantly capture signals and feed them back to the equipment control system. This ensures real-time adjustment of oxygen supply parameters, avoiding the fatal risks of oxygen toxicity caused by excessively high concentrations and hypoxia due to excessively low concentrations. Compared with some ordinary sensors in the industry with a response time of 30-60s, the core advantage of the ATO-AOX3100 oxygen sensor lies not only in its "speed" but also in the "stability" brought by fast response — it enables medical equipment to achieve efficient closed-loop operation of "concentration monitoring - parameter adjustment", providing reliable monitoring data support for medical staff, reducing medical errors caused by signal delays, and ultimately building a solid line of defense for patients' lives.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

ATO medical oxygen sensor is a full-range oxygen sensor using voltage divider electrochemistry technology. It has a measurement range of 0-100%, a response time of less than 15 seconds, and is equipped with temperature compensation (0-40℃) to ensure accurate and stable detection. Medical O2 sensor does not require an external power supply, is lead-free and environmentally friendly, and can be directly integrated into medical devices such as oxygen generators and anesthesia equipment. Meanwhile, O2 oxygen sensor's lead-free and environmentally friendly characteristics meet the demand for green products in the medical field, providing a reliable and efficient solution for oxygen concentration monitoring in medical scenarios.

Specification

ModelATO-AOX3100
Detectable Gas TypeOxygen
Working PrincipleVoltage Divider Electrochemistry
Output Voltage9-14mV (in air)
Measurement Range0-100%
Response Time (T90)<15s
LinearityFull-scale Linear
Temperature Compensation<2% O2 equivalent (0-40℃)
Load Resistance≥10kΩ
InterfaceMolex 3-pin header (2.54mm) (MOLEX 22-29-2031)
Recommended Matching InterfaceMolex wire harness (MOLEX 22-01-2035)
Molex crimp terminal (MOLEX 08-45-0110)
Housing MaterialWhite HDPE
Weight30g
Operating Temperature Range0-50℃
Recommended Storage Temperature5-15℃
Operating Pressure Range0.5-2.0bar
Operating Humidity Range0-99% RH (no condensation)
Long-term Drift in 100% O2 Environment<5% (voltage decay/year)
Expected Service Life24 months
Warranty Period12 months


Features

Measurement Performance: 0-100% full-scale linear measurement with response time <15s, output voltage 9-14mV (in air), and temperature compensation <2% O2 equivalent (0-40℃), ensuring high accuracy and stability.
Convenience & Integration: No external power supply required, comes with Molex 3-pin interface (2.54mm) and recommended matching wire harness and crimp terminal for easy integration.
Environmental & Durability: Medical oxygen sensor is lead-free and RoHS compliant, with white HDPE housing. It has an expected service life of 24 months, a warranty period of 12 months, and can operate in a temperature range of 0-50℃, humidity range of 0-99% RH (no condensation), and pressure range of 0.5-2.0bar.
Application: O2 sensor is suitable for medical devices such as oxygen concentrator control devices, medical ventilators, anesthesia equipment, as well as incubators and other scenarios requiring oxygen concentration monitoring, also performs excellently in the automobile, fire-fighting, and coal mining industries.

Pin Definition

Medical O2 sensor pin definition

Dimension (Unit: mm)

Medical O2 sensor dimension

Application

Medical O2 sensor appliation

Tips: How Does Response Time Affect Performance of Oxygen Sensor in Medical Industry?

Among the core performance indicators of medical devices, "response time" is a key parameter for evaluating the suitability of oxygen sensors in clinical scenarios, directly related to the accuracy and timeliness of medical monitoring. The T₉₀ response time is even recognized as the industry's core evaluation standard. Simply put, the T90 response time refers to the time required for an oxygen sensor to stabilize its output signal to 90% of the final target value after coming into contact with the target oxygen concentration environment. The value directly reflects the sensor's "perceptual sensitivity" to changes in oxygen concentration — the smaller the value, the faster the sensor's reaction speed, enabling it to capture concentration fluctuations and feedback valid signals in a shorter time. In the medical field, especially for life-support equipment, the T90 response time is by no means a dispensable technical parameter, but a "threshold" that determines whether a sensor meets clinical requirements, and it directly safeguards patients' lives.

ATO medical oxygen sensor is equipped with a T90 response time of <15s, demonstrating irreplaceable value in medical industry applications. Its importance and advantages are reflected in multiple core scenarios. In life-support equipment such as ventilators and anesthesia machines, the fast response of <15s can accurately adapt to the dynamic breathing needs of critically ill patients: whether it is the breathing fluctuations of patients with acute respiratory distress syndrome or changes in airway oxygen concentration during surgical anesthesia, the sensor can instantly capture signals and feed them back to the equipment control system. This ensures real-time adjustment of oxygen supply parameters, avoiding the fatal risks of oxygen toxicity caused by excessively high concentrations and hypoxia due to excessively low concentrations. Compared with some ordinary sensors in the industry with a response time of 30-60s, the core advantage of the ATO-AOX3100 oxygen sensor lies not only in its "speed" but also in the "stability" brought by fast response — it enables medical equipment to achieve efficient closed-loop operation of "concentration monitoring - parameter adjustment", providing reliable monitoring data support for medical staff, reducing medical errors caused by signal delays, and ultimately building a solid line of defense for patients' lives.

Only registered users can write reviews
Customers who bought this item also bought

Oxygen Gas Sensor/Transmitter, RS485/4-20mA/0-5V

ATO-GS-O2-3002
$101.58
The oxygen gas sensor measures ranges of 0-30%VOL for RS485 output and 0-25%VOL for analog output, with an accuracy of ±3%FS and a resolution of 0.1%VOL. Gas transmitter has a power supply range of 10~30V DC, with the 0~10V output type requiring a 24V supply. Widely used in industries such as process control, environmental monitoring, medical devices, food and beverage, safety detection, scientific research, and combustion system optimization.

Pressure Sensor for Air/Water/Oil, 4-20mA/RS485/0-5V/0-10V Output

ATO-PRES-P300S
$119.68
Low-range pressure sensor provides 0–10/20/50/100 kPa, -100–0 kPa and -100–100 kPa options with current, voltage or RS485 outputs. Designed for low-pressure and vacuum/compound pressure measurement of air, water and oil, with flexible 12V, 24V or 12–36V DC power supply.