Pressure Sensor for Air/Water/Oil, 4-20mA/RS485/0-5V/0-10V Output

$119.68
Low-range pressure sensor provides 0–10/20/50/100 kPa, -100–0 kPa and -100–100 kPa options with current, voltage or RS485 outputs. Designed for low-pressure and vacuum/compound pressure measurement of air, water and oil, with flexible 12V, 24V or 12–36V DC power supply.
SKU: ATO-PRES-P300S
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

High performance pressure sensor for sale online. It is available with 0~10kPa, 0~20kPa, 0~50kPa, 0~100kPa, -100~0kPa, and-100~100kPa measuring range, 4-20mA, 0-5V, 1-5V, 0-10V, RS485 output signals, and DC 12V, DC 24V or DC 12-36V power supply, specially used for measuring air, water or oil pressure.

Specifications

  • Model: ATO-PRES-P300
  • Measuring Range: 0~10kPa, 0~20kPa, 0~50kPa, 0~100kPa, -100~0kPa, -100~100kPa
  • Output Signal: 4-20mA, 0-5V, 1-5V, 0-10V, RS485
  • Accuracy: ±0.5%FS,  ±1%FS
  • Power Supply: DC 12V, DC 24V, DC 12-36V
  • Electrical Connection: DIN Connector Type, Direct Lead Wire Type, M12 Circular Connector Type
  • Thread of Pressure Connection: G1/4, G1/2, 1/4 NPT, 1/2 NPT, M14*1.5, M20*1.5
  • Protection Class: IP65
  • Measuring Medium: Air, Water and Oil (Non-explosion Proof Area)
  • Pressure Type: Gauge Pressure (Standard), Contact Us for Absolute Pressure and Sealed Pressure Type (Note: The measuring range for these two types must be ≤ 1MPa)
  • Application: Pressure sensor is widely used in process control, aerospace, automotive, medical equipment, HVAC and other fields.

Pressure Sensor Dimension Drawing (Unit: mm)
Pressure sensor dimensional drawing

Pressure Sensor Wiring Diagram
Pressure sensor wiring diagram

Tips: What is the output singal of the pressure sensor?

The output signal of a pressure sensor depends on the specific model and configuration, but common types include:

  • 4–20mA: Most common in industrial applications. It is noise-resistant and allows long cable runs.
  • 0–5V/1–5V/0–10V: Voltage outputs are common in general-purpose applications. 0–5V and 1–5V are typical for lower voltage systems. 0–10V provides a wider range but is more sensitive to electrical noise.
  • RS485 (Modbus RTU): A digital output type used for remote communication and advanced monitoring. Allows multiple sensors on a single bus and can provide more detailed data (e.g., pressure, temperature, diagnostics).

Measuring range conversion table:

UnitkPaMPabarpsi
Measuring range0~50~0.0050~0.050~0.7
0~100~0.010~0.10~1.5
0~200~0.020~0.20~3
0~500~0.050~0.50~7
0~1000~0.10~10~14
-100~0-0.1~0-1~0-14~0
-100~100-0.1~0.1-1~1-14~14
0~6000~0.60~60~87
0~10000~10~100~145
0~16000~1.60~160~232
0~25000~2.50~250~362
0~60000~60~600~870
0~100000~100~1000~1450
0~200000~200~2000~2900
0~300000~300~3000~4351
0~400000~400~4000~5801
0~500000~500~5000~7252
0~600000~600~6000~8702
0~1000000~1000~10000~14503



Related videos for ATO pressure sensors:

How to install and wire a pressure sensor?

How to install a constant pressure water pump with digital pressure sensor?

Pressure sensor 4-20mA output wiring details

VFD Constant Pressure Water Supply System Wiring and Testing

The video shows a 4~20mA pressure sensor connected to an ATO VFD to form a constant pressure water supply system.

Product reviews
It's a pretty good deal.
5
Alex
Avatar
9/2/2025 2:35 AM
The previous sensor broke, so I bought two of these as replacements. I chose the 0-100kPa   4-20mA model. When it arrived, I found the threading matched the original port perfectly—no need to re-tap the hole. Installation took just twenty minutes. After two months of use, the pressure readings on the PLC have remained consistently stable with no fluctuations. The cost-performance ratio is significantly better than the imported brand I bought before.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High performance pressure sensor for sale online. It is available with 0~10kPa, 0~20kPa, 0~50kPa, 0~100kPa, -100~0kPa, and-100~100kPa measuring range, 4-20mA, 0-5V, 1-5V, 0-10V, RS485 output signals, and DC 12V, DC 24V or DC 12-36V power supply, specially used for measuring air, water or oil pressure.

Specifications

  • Model: ATO-PRES-P300
  • Measuring Range: 0~10kPa, 0~20kPa, 0~50kPa, 0~100kPa, -100~0kPa, -100~100kPa
  • Output Signal: 4-20mA, 0-5V, 1-5V, 0-10V, RS485
  • Accuracy: ±0.5%FS,  ±1%FS
  • Power Supply: DC 12V, DC 24V, DC 12-36V
  • Electrical Connection: DIN Connector Type, Direct Lead Wire Type, M12 Circular Connector Type
  • Thread of Pressure Connection: G1/4, G1/2, 1/4 NPT, 1/2 NPT, M14*1.5, M20*1.5
  • Protection Class: IP65
  • Measuring Medium: Air, Water and Oil (Non-explosion Proof Area)
  • Pressure Type: Gauge Pressure (Standard), Contact Us for Absolute Pressure and Sealed Pressure Type (Note: The measuring range for these two types must be ≤ 1MPa)
  • Application: Pressure sensor is widely used in process control, aerospace, automotive, medical equipment, HVAC and other fields.

Pressure Sensor Dimension Drawing (Unit: mm)
Pressure sensor dimensional drawing

Pressure Sensor Wiring Diagram
Pressure sensor wiring diagram

Tips: What is the output singal of the pressure sensor?

The output signal of a pressure sensor depends on the specific model and configuration, but common types include:

  • 4–20mA: Most common in industrial applications. It is noise-resistant and allows long cable runs.
  • 0–5V/1–5V/0–10V: Voltage outputs are common in general-purpose applications. 0–5V and 1–5V are typical for lower voltage systems. 0–10V provides a wider range but is more sensitive to electrical noise.
  • RS485 (Modbus RTU): A digital output type used for remote communication and advanced monitoring. Allows multiple sensors on a single bus and can provide more detailed data (e.g., pressure, temperature, diagnostics).
Product reviews
It's a pretty good deal.
5
Alex
Avatar
9/2/2025 2:35 AM
The previous sensor broke, so I bought two of these as replacements. I chose the 0-100kPa   4-20mA model. When it arrived, I found the threading matched the original port perfectly—no need to re-tap the hole. Installation took just twenty minutes. After two months of use, the pressure readings on the PLC have remained consistently stable with no fluctuations. The cost-performance ratio is significantly better than the imported brand I bought before.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Pressure Sensor for Air/Water/Oil, 4-20mA/0-5V/RS485 Output

ATO-PRES-P300
$119.68
Silicon piezoresistive pressure sensor covers -0.1 to 100 MPa with 4–20mA, 0–20mA, multiple voltage or RS485 output options. Stainless steel construction supports air, water and oil pressure measurement at medium temperatures from -40°C to 60°C.

Digital Pressure Sensor for Hydraulic/Steam/Air

ATO-PRES-PX300
$173.33
Digital pressure sensor covers -0.1 to 100 MPa and supports 4–20mA, 0–20mA, voltage and RS485 outputs, with a backlit LCD display. Suitable for hydraulic, steam, air and liquid pressure measurement, with medium temperatures from -40°C to 60°C.

3 hp (2.2 kW) VFD, Single Phase Input & Output

GK3000-1S0022
$379.23
Cheap 3 hp VFD, 1 phase for single phase AC induction motor, good variable speed performance, 220V - 240V 17 amps, manufacturer direct sale.

Oxygen Gas Sensor/Transmitter, RS485/4-20mA/0-5V

ATO-GS-O2-3002
$101.58
The oxygen gas sensor measures ranges of 0-30%VOL for RS485 output and 0-25%VOL for analog output, with an accuracy of ±3%FS and a resolution of 0.1%VOL. Gas transmitter has a power supply range of 10~30V DC, with the 0~10V output type requiring a 24V supply. Widely used in industries such as process control, environmental monitoring, medical devices, food and beverage, safety detection, scientific research, and combustion system optimization.

Medical Oxygen Sensor, Lead-free, 0-100% Linear

ATO-GS-O2-3100
$104.46
Factory price medical oxygen sensor is for sale. It is based on the voltage divider electrochemistry principle, featuring linear measurement across the full range of 0 - 100%, a response time of less than 15 seconds, and high precision and efficiency. O2 oxygen sensor is lead-free and complies with the RoHS standard, can be widely used in medical equipment such as oxygen generators and medical ventilators.