Mechanical Limit Switch with Roller Lever/Plunger, IP65 Waterproof

$63.46
Mechanical limit switch features a roller lever or plunger design, achieving an IP65 waterproof rating suitable for use in humid or dusty conditions. The waterproof limit switch supports a rated current of 10A 125/250V AC and 0.5A 125V DC, providing versatile electrical control options, and includes both normally open (NO) and normally closed (NC) contacts, suitable for applications in automation equipment, mechanical operations, and more.
SKU: ATO-LS-LZ5
*
Free Shipping
Delivery date: 6-12 days

Mechanical limit switch reaches IP65 protection level, which can prevent dust, oil, and water, ensuring reliable operation in various industrial environments, with long-term stability and durability.

Features

  • Waterproof limit switch features a dustproof, oil-proof, and waterproof design (IP65 rating).
  • It offers various types of actuators to choose from.
  • Sealed limit switch boasts high mechanical durability and strength.
  • It operates with high precision and rapid action.
  • Mechanical limit switch finds wide applications in production equipment, machinery, and automation.
  • It holds CCC and CE certifications, guaranteeing quality and safety compliance.

Specification

ModelATO-LZ5
Rating10A 125/250VAC 0.5A 125VDC
Initial contact resistance25mΩ max.
Initial insulation resistance100mΩ min. (at 500VDC)
Dielectric strengthBetween non-consecutive terminals1000Vrms, 50/60Hz for 1 min
Between non-current carrying metal parts and each terminal2000Vrms, 50/60Hz for 1 min
Between ground and each terminal2000Vrms, 50/60Hz for 1 min
Max.shock resistanceDestruction1000m/s2
Malfunction300m/s2
Vibration resistance10-55Hz, 1.5mm double amplitude
Operating lifeMechanical life1,000,000 times min.
Electrical life100,000 times min.
Ambient temperature-10℃ to +85℃
Ambient humidity95%RH max.
Operating frequencyMechanical120 times/min
Electrical30 times/min
Operating speed0.01mm-50cm/s
Protection degreeIP65


Actuator Operating Characteristic

ModelLZ5120 (Short roller lever)
ModelLZ5121 (Roller lever)
O.F. max.300g (2.94N)O.F. max.200g (1.96N)
R.F. min.40g (0.39N)R.F. min.40g (0.39N)
O.T. min.2mmO.T. min.5mm
M.D. max.1.5mmM.D. max.3mm
O.P.40±1 mmO.P.40±1 mm
F.P. max.47mmF.P. max.51mm
ModelLZ5341 (Panel mount across roller plunger)ModelLZ5342 (Panel mount roller plunger)
O.F. max.600g (5.88N)O.F. max.600g (5.88N)
R.F. min.100g (0.98N)R.F. min.100g (0.98N)
P.T. max.1.6mmP.T. max.1.6mm
O.T. min.5mmO.T. min.5mm
M.D. max.0.2mmM.D. max.0.2mm
O.P.33.4±1.2 mmO.P.33.4±1.2 mm

OF: Operating Force
RF: Release Force
PT: Pre-Travel
OT: Over Travel
MD: Movement Differential
OP: Operating Position
FP: Free Position

Contact Form

Mechanical limit switch contacts

Actuators

Mechanical limit switch with short roller lever

LZ5120 (Short roller lever)

Mechanical limit switch roller lever

LZ5121 (Roller lever)

Mechanical limit switch panel mount across roller plunger

LZ5341 (Panel mount across roller plunger)

Mechanical limit switch panel mount roller plunger

LZ5342 (Panel mount roller plunger)


Tips: Some precautions for using mechanical limit switch

  1. Installation Orientation: Ensure the switch is installed correctly to match the movement of the actuator (roller lever or plunger). Improper orientation can affect performance and longevity.
  2. Actuator Alignment: Properly align the roller lever or plunger with the moving parts it interacts with. Misalignment can cause premature wear or failure.
  3. Environmental Conditions: Despite IP65 rating, avoid extreme environmental conditions like excessive vibration, extreme temperatures, or corrosive atmospheres that can degrade the switch over time.
  4. Operating Force: Be mindful of the force applied to the actuator. Excessive force can damage internal components or lead to inaccurate switching.
  5. Maintenance: Regularly inspect and maintain the switch and actuator to ensure proper operation. Clean and lubricate as necessary to prevent buildup or sticking.
  6. Electrical Ratings: Adhere to the specified electrical ratings (voltage and current) to prevent electrical damage or safety hazards.
  7. Testing: Before putting into service, test the switch and actuator to ensure they operate correctly and reliably under normal operating conditions.

Mounting Holes Dimensions (mm)

Mechanical limit switch installing dimension

Specific Model Dimensions (mm)

Mechanical limit switch with short roller lever dimension

Mechanical limit switch with roller lever dimension

Mechanical limit switch with panel mount across roller plunger dimension

Mechanical limit switch panel mount roller plunger dimension

VFD Emergency Stop with Limit Switches

In this video, you will learn about the setup and operation of emergency stopping a motor by using limit switches and a variable frequency drive (VFD). By combining the limit switches of the emergency stop function with the VFD GK3000, a strong safety measure can be established that can quickly stop the motor operation in an emergency.

Automatic Material Trolley Control with Limit Switch

In this video, the method of applying limit switches to automatic material trolley control is demonstrated.

Roller Limit Switch NO NC Contact Wiring and Detection

In this video, the roller limit switch NO NC contact wiring and detection operation are shown.

Product reviews
I need to purchase limit switches
5
Kuoli
Avatar
8/10/2026 1:28 AM
I need two single-pole double-throw (SPDT) microswitches, 24VDC.
Was this review helpful? Yes No (0/0)
ATO Responded
Our microswitch SKU is ATO-LS-LZ5. Please check the specifications on our website to see if they meet your requirements.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Mechanical limit switch reaches IP65 protection level, which can prevent dust, oil, and water, ensuring reliable operation in various industrial environments, with long-term stability and durability.

Features

  • Waterproof limit switch features a dustproof, oil-proof, and waterproof design (IP65 rating).
  • It offers various types of actuators to choose from.
  • Sealed limit switch boasts high mechanical durability and strength.
  • It operates with high precision and rapid action.
  • Mechanical limit switch finds wide applications in production equipment, machinery, and automation.
  • It holds CCC and CE certifications, guaranteeing quality and safety compliance.

Specification

ModelATO-LZ5
Rating10A 125/250VAC 0.5A 125VDC
Initial contact resistance25mΩ max.
Initial insulation resistance100mΩ min. (at 500VDC)
Dielectric strengthBetween non-consecutive terminals1000Vrms, 50/60Hz for 1 min
Between non-current carrying metal parts and each terminal2000Vrms, 50/60Hz for 1 min
Between ground and each terminal2000Vrms, 50/60Hz for 1 min
Max.shock resistanceDestruction1000m/s2
Malfunction300m/s2
Vibration resistance10-55Hz, 1.5mm double amplitude
Operating lifeMechanical life1,000,000 times min.
Electrical life100,000 times min.
Ambient temperature-10℃ to +85℃
Ambient humidity95%RH max.
Operating frequencyMechanical120 times/min
Electrical30 times/min
Operating speed0.01mm-50cm/s
Protection degreeIP65


Actuator Operating Characteristic

ModelLZ5120 (Short roller lever)
ModelLZ5121 (Roller lever)
O.F. max.300g (2.94N)O.F. max.200g (1.96N)
R.F. min.40g (0.39N)R.F. min.40g (0.39N)
O.T. min.2mmO.T. min.5mm
M.D. max.1.5mmM.D. max.3mm
O.P.40±1 mmO.P.40±1 mm
F.P. max.47mmF.P. max.51mm
ModelLZ5341 (Panel mount across roller plunger)ModelLZ5342 (Panel mount roller plunger)
O.F. max.600g (5.88N)O.F. max.600g (5.88N)
R.F. min.100g (0.98N)R.F. min.100g (0.98N)
P.T. max.1.6mmP.T. max.1.6mm
O.T. min.5mmO.T. min.5mm
M.D. max.0.2mmM.D. max.0.2mm
O.P.33.4±1.2 mmO.P.33.4±1.2 mm

OF: Operating Force
RF: Release Force
PT: Pre-Travel
OT: Over Travel
MD: Movement Differential
OP: Operating Position
FP: Free Position

Contact Form

Mechanical limit switch contacts

Actuators

Mechanical limit switch with short roller lever

LZ5120 (Short roller lever)

Mechanical limit switch roller lever

LZ5121 (Roller lever)

Mechanical limit switch panel mount across roller plunger

LZ5341 (Panel mount across roller plunger)

Mechanical limit switch panel mount roller plunger

LZ5342 (Panel mount roller plunger)


Tips: Some precautions for using mechanical limit switch

  1. Installation Orientation: Ensure the switch is installed correctly to match the movement of the actuator (roller lever or plunger). Improper orientation can affect performance and longevity.
  2. Actuator Alignment: Properly align the roller lever or plunger with the moving parts it interacts with. Misalignment can cause premature wear or failure.
  3. Environmental Conditions: Despite IP65 rating, avoid extreme environmental conditions like excessive vibration, extreme temperatures, or corrosive atmospheres that can degrade the switch over time.
  4. Operating Force: Be mindful of the force applied to the actuator. Excessive force can damage internal components or lead to inaccurate switching.
  5. Maintenance: Regularly inspect and maintain the switch and actuator to ensure proper operation. Clean and lubricate as necessary to prevent buildup or sticking.
  6. Electrical Ratings: Adhere to the specified electrical ratings (voltage and current) to prevent electrical damage or safety hazards.
  7. Testing: Before putting into service, test the switch and actuator to ensure they operate correctly and reliably under normal operating conditions.
Product reviews
I need to purchase limit switches
5
Kuoli
Avatar
8/10/2026 1:28 AM
I need two single-pole double-throw (SPDT) microswitches, 24VDC.
Was this review helpful? Yes No (0/0)
ATO Responded
Our microswitch SKU is ATO-LS-LZ5. Please check the specifications on our website to see if they meet your requirements.
Only registered users can write reviews