DC Voltage Monitoring Relay, Under/Over Voltage, 12V/24V/48V DC

$105.98
DC voltage monitoring relay with 2 C/O contacts (2 Form C or DPDT) provide protection for the equipment from undervoltage and overvoltage in DC circuit 12V, 24V, 36V or 48V, adjustable trip delay time, LED indicator for working state, DIN rail mounting, compact design, good quality and low price.
SKU: ATO-MR-DVRD
*
Free Shipping
Delivery date: 6-12 days

This voltage monitoring relay is applied in the DC circuit for monitoring undervoltage and overvoltage of DC cabinet, battery, electric control system, etc.

Features

  • Compact size in DIN rail mounting
  • DC circuit monitoring of overvoltage and undervoltage
  • Adjustable overvoltage and undervoltage threshold
  • Adjustable trip delay time
  • Powered by the measuring circuit
  • Monitoring relay with 2 C/O contacts (2 Form C or DPDT)
  • 2 LEDs for status indication

Specification

ModelATO-DVRD-12ATO-DVRD-24ATO-DVRD-36ATO-DVRD-48
Measuring CircuitDC circuit
Monitoring FunctionsOvervoltage, Undervoltage
Rated VoltageDC 12VDC 24VDC 36VDC 48V
Voltage Setting RangeUndervoltage10-14V20-28V30-42V40-56V
Overvoltage13-17V26-34V39-51V52-68V
Trip Delay Time0.1-15s adjustable
Voltage Hysteresis3-5% fixed
IndicatorsLED indicators for Normal, Trip
Output Contacts2 C/O
Contact Capacity6A, 250V AC (resistive load)
Degree of ProtectionIP 20
CertificationCE
Working ConditionsOperating Temperature-25℃~65℃
Humidity≤85%RH, non-condensing
Mechanical Durability1,000,000 cycles
Dielectric Strength>2kVAC 1min
Power Consumption≤2W
Mounting35mm DIN rail
Weight130g
Dimensions (H*W*D)79*23*79mm

Wiring Diagram

DC Voltage Monitor Relay Wiring Diagram

Monitoring relay contactor wiring

Dimensions (Unit: mm)

DC Voltage Monitor Relay Dimension

Details

DC Voltage Monitoring Relay Details

Tips: Is an AC Voltage Monitoring Relay Effective?

1. The voltage monitoring relay must be able to withstand an AC voltage above 450V.
For 3-phase 380V AC, the grid voltage sometimes has 380V-450V at zero-break, the voltage monitoring relay can be tested before installation, and the relay can be directly connected to the two fire lines for more than 4 hours to confirm whether it can withstand. Of course, it can not ignore whether the voltage monitoring relay can work normally at low voltage. You can use a voltage regulator, and adjust it to about 60V for testing.

2. The voltage monitoring relay should be able to set the trip protection value according to the rated voltage of the electrical appliance to be protected.
The setting of the trip protection value must be based on the nameplate identification or instruction manual on the electrical product. Do not set it too high or too low, otherwise the performance and life of the electrical appliance will be greatly reduced or even damaged.

3. The response speed of the voltage monitoring relay should be fast.
When the voltage is abnormal, the relay can quickly cut off the power, and the sooner the better.

4. The voltage monitoring relay should be able to set the delayed closing time according to the characteristics of the electrical appliance being protected.
This is also very important, because some electrical appliances can not be powered on immediately after power failure; then the delayed closing is a better protection for electrical appliances.

3-Phase Monitoring Relay Phase Failure & Phase Sequence Testing

In this video, we will give you a test of ATO 3-phase monitoring relay on phase failure and phase sequence, and the relay does the job at such these cases to protect the motor. In addition, this multi-purpose monitoring relay has other monitoring functions such as undervoltage, overvoltage, voltage unbalance, timer & counter.

Working Principles 3-Phase Monitoring Relay 

3-phase Monitoring Relay Phase Failure and Sequence Test

In this video, the phase failure and sequence test of the 3-phase monitoring relay is introduced.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Looking for DC voltage monitoring relay
5
Carlos
Avatar
11/27/2019 5:57 PM
What is the power consumption of this DC voltage monitoring relay during normal operation and when a under voltage occurrence is in?
Was this review helpful? Yes No (0/0)
ATO Responded
The power consumption of this relay is ≤2W during normal operation, and when the under-voltage occurs, the power consumption will be smaller than this. And you can adjust the over-voltage and under-voltage threshold in the voltage setting range as you like.
Reliable Monitoring
5
Cassian
Avatar
11/23/2023 1:41 AM
The continuous monitoring of DC voltage ensures real-time awareness of the electrical system's status. In the event of voltage deviations beyond the set thresholds, the relay responds promptly, providing an added layer of protection.
Was this review helpful? Yes No (0/0)
I have some questions
4
Izefia
Avatar
10/10/2024 12:22 AM
What wire gauge sizes do the terminals accept? (Will the terminals allow for #14 AWG wiring?) Is the relay "energized" under normal operation, or when the relay senses an out-of-range voltage (based on the adjustable setpoints)?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The terminals support a maximum of 2.5mm² wire, and the terminals allow for #14 AWG wiring, no problem.
2. Whether the relay "energized" under normal operation under normal operation, the positive/negative terminals of the relay will be connected to the monitored circuit until an overvoltage/undervoltage is detected, triggering the relay signal.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

This voltage monitoring relay is applied in the DC circuit for monitoring undervoltage and overvoltage of DC cabinet, battery, electric control system, etc.

Features

  • Compact size in DIN rail mounting
  • DC circuit monitoring of overvoltage and undervoltage
  • Adjustable overvoltage and undervoltage threshold
  • Adjustable trip delay time
  • Powered by the measuring circuit
  • Monitoring relay with 2 C/O contacts (2 Form C or DPDT)
  • 2 LEDs for status indication

Specification

ModelATO-DVRD-12ATO-DVRD-24ATO-DVRD-36ATO-DVRD-48
Measuring CircuitDC circuit
Monitoring FunctionsOvervoltage, Undervoltage
Rated VoltageDC 12VDC 24VDC 36VDC 48V
Voltage Setting RangeUndervoltage10-14V20-28V30-42V40-56V
Overvoltage13-17V26-34V39-51V52-68V
Trip Delay Time0.1-15s adjustable
Voltage Hysteresis3-5% fixed
IndicatorsLED indicators for Normal, Trip
Output Contacts2 C/O
Contact Capacity6A, 250V AC (resistive load)
Degree of ProtectionIP 20
CertificationCE
Working ConditionsOperating Temperature-25℃~65℃
Humidity≤85%RH, non-condensing
Mechanical Durability1,000,000 cycles
Dielectric Strength>2kVAC 1min
Power Consumption≤2W
Mounting35mm DIN rail
Weight130g
Dimensions (H*W*D)79*23*79mm

Wiring Diagram

DC Voltage Monitor Relay Wiring Diagram

Monitoring relay contactor wiring

Dimensions (Unit: mm)

DC Voltage Monitor Relay Dimension

Details

DC Voltage Monitoring Relay Details

Tips: Is an AC Voltage Monitoring Relay Effective?

1. The voltage monitoring relay must be able to withstand an AC voltage above 450V.
For 3-phase 380V AC, the grid voltage sometimes has 380V-450V at zero-break, the voltage monitoring relay can be tested before installation, and the relay can be directly connected to the two fire lines for more than 4 hours to confirm whether it can withstand. Of course, it can not ignore whether the voltage monitoring relay can work normally at low voltage. You can use a voltage regulator, and adjust it to about 60V for testing.

2. The voltage monitoring relay should be able to set the trip protection value according to the rated voltage of the electrical appliance to be protected.
The setting of the trip protection value must be based on the nameplate identification or instruction manual on the electrical product. Do not set it too high or too low, otherwise the performance and life of the electrical appliance will be greatly reduced or even damaged.

3. The response speed of the voltage monitoring relay should be fast.
When the voltage is abnormal, the relay can quickly cut off the power, and the sooner the better.

4. The voltage monitoring relay should be able to set the delayed closing time according to the characteristics of the electrical appliance being protected.
This is also very important, because some electrical appliances can not be powered on immediately after power failure; then the delayed closing is a better protection for electrical appliances.

Product reviews
Looking for DC voltage monitoring relay
5
Carlos
Avatar
11/27/2019 5:57 PM
What is the power consumption of this DC voltage monitoring relay during normal operation and when a under voltage occurrence is in?
Was this review helpful? Yes No (0/0)
ATO Responded
The power consumption of this relay is ≤2W during normal operation, and when the under-voltage occurs, the power consumption will be smaller than this. And you can adjust the over-voltage and under-voltage threshold in the voltage setting range as you like.
Reliable Monitoring
5
Cassian
Avatar
11/23/2023 1:41 AM
The continuous monitoring of DC voltage ensures real-time awareness of the electrical system's status. In the event of voltage deviations beyond the set thresholds, the relay responds promptly, providing an added layer of protection.
Was this review helpful? Yes No (0/0)
I have some questions
4
Izefia
Avatar
10/10/2024 12:22 AM
What wire gauge sizes do the terminals accept? (Will the terminals allow for #14 AWG wiring?) Is the relay "energized" under normal operation, or when the relay senses an out-of-range voltage (based on the adjustable setpoints)?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The terminals support a maximum of 2.5mm² wire, and the terminals allow for #14 AWG wiring, no problem.
2. Whether the relay "energized" under normal operation under normal operation, the positive/negative terminals of the relay will be connected to the monitored circuit until an overvoltage/undervoltage is detected, triggering the relay signal.
Only registered users can write reviews
Customers who bought this item also bought

Voltage Monitoring Relay, Under/Over Voltage, 1 Phase, 110-240V AC/DC

ATO-MR-SVR1000
$115.67
Single phase voltage monitoring relay, suitable for undervoltage and overvoltage monitoring of DC 12V, AC/DC 24-48V or AC/DC 110V-240V, adjustable delay time, compact size relay with 1 CO & 1 NC contacts, real-time LCD for voltage, operation and fault status display, DIN rail mounting, high quality and low cost.

50A High Voltage DC Contactor, 12V/24V coil

ATO-DCCON-HV50
$111.85
High voltage DC contactor, normally open type (SPST-NO), 50 amps rated load current of contact circuit, available with 12V or 24V coils, the connection of contact and coil need to be nonpolarity. It is widely used in the DC high voltage field, such as electric car, wind power generation, DC power supply control system and so on.

50A DC Reversing Contactor, 2 pole, 12V/24V/48V

ATO-DCCON-R50
$74.31
Two pole DC reversing contacor with 2 sets of switching contacts, 2NO and 2NC form, 50 amps rated load current of contact circuit, coil rated voltage with 12V/24V/48V DC for selection. Cheap price and manufacturer direct sale.

100A DC Contactor, 12V/24V/48V

ATO-DCCON-C100
$103.63
High performance 100A DC contactor with normally open or normally closed main contact type, and available with two optional auxiliary contacts. Coil rated voltage with 12V/24V/48V for selection, main contact voltage drop at 100A, not above 100mV.

40 amp 3/4 Pole DC Coil Contactor, 12V/24V/48V/220V Coil

ATO-DCCON-40A
$155.24
3 or 4 pole AC contactor is a DC controlled electrical switching device to control electric motors, lighting and other electrical loads at 40 amp rated current. Rated power up to 30 kW, contact form 3 NO or 2NO+2NC, coil rated voltage of 12V, 24V, 36V, 48V, 110V, 220V for your choices.