Features
- DC 12-900V rated load voltage of contact circuit.
- SPST-NO of contact form, 12 volt, 24 volt coil for selecting.
- Main contact voltage drop at 50A, not above 100mV.
- The connection of contact and coil need to be nonpolarity.
- Efficient coil, retentive power is only 2-2.3W, counter electromotive force is 0V.
- The joint way of the coil is very convenient.
- The coil has no counter force of electromagnetism.
- Compare to the similar products, this product is smallest and lightest.
Specifications
| Basics | Model | ATO-ADH50 | |
| Dimension | 55 x 42 x 62 mm | ||
| Weight | 230 g | ||
| Main Contact Parameters | Contact Form | 1 NO | |
| Leading-Out | M5 internal thread/18 mm | ||
| Rated Load Current | 50 A | ||
| Rated Load Voltage | 12 – 900V DC | ||
| Maximum Switching Current | 500A 320V DC (≥1 times) | ||
| Maximum Switching Power | 160 kW | ||
| Rated Electric Life | 10,000 times | ||
| Coil Parameters | Standard Type Voltage | 12V DC | 24V DC |
| Work Voltage | 9~16V | 18~32 V | |
| Max Voltage | 16 V | 32 V | |
| Coil Resistance | 26 Ω | 96 Ω | |
| Average Holding Current | 0.46 A | 0.25 A | |
| Steady State Power | 5.5 W | 6 W | |
| Actuation Time | ≤25 ms | ||
| Release Time | ≤10 ms | ||
| Bounce Time | ≤5 ms | ||
| Mechanical Specification | Stability | 196 m/s2 (20G) | |
| Strength | 490 m/s2 (50G) | ||
| Vibration | 80 ~2000Hz 98m/s2 (20G) | ||
| IP Grade | IP67 | ||
| Environment | Operating Temperature | -40℃~85℃ | |
| Operating Humidity | 5~95% RH | ||
Installation Diagram (Unit: mm)
High Voltage DC Contactor Coil Schematic
Details

Tips: Fusion welding of the contactor due to electric shock, how to solve?
Possible causes of the fault:
- short circuit of contactor on the load side.
- Overload use of contactor contact.
- There’s a foreign body or a metal particle on the surface of the contact.
- Pressure of the contact spring is too small.
- Poor contact of contactor's lines, which makes the contactor repeatedly pull in and release at a moment.
Maintenance method:
- Power off at first, separate the welding contacts with a screwdriver, correct the contact surface and eliminate the short-circuit fault.
- Replace with a large capacity and high quality contactor.
- Smooth the contact surface with a steel file and remove foreign bodies.
- Readjust the spring pressure.
- Check the bad contacts of the coil control loop of the contactor, reconnect the loop or replace electrical components, ensure a good on-off situation.
Product reviews
Does your 50A high voltage DC contactor have a gas or vacuum filled arc chamber?
Covfe
11/2/2021 12:08 AM
I want to ask if your 50A high voltage DC contactor ADH150/900-E has a gas or vacuum filled arc chamber?
Was this review helpful? (0/0)
Few questions
Puth
12/10/2021 1:32 AM
1. Why does the DC version cost 20$ more? Is there a difference in the internal structure between AC coil and DC coil?
2. What are the typical open/close times?
3. The supported altitude is 2000m. Is there an option to increase it to 2500m?
2. What are the typical open/close times?
3. The supported altitude is 2000m. Is there an option to increase it to 2500m?
Was this review helpful? (0/0)
What part number should we order?
rayparker
6/29/2023 7:06 PM
We need two N.O. contactors rated at 150 amps with 12-volt coils and specified to use your 200 amp, with N.O. and assuming the use of an auxiliary NO, what part number should we order?
Was this review helpful? (0/0)
What is the internal difference between an AC and a DC contactor?
niki
7/19/2023 11:49 PM
What is the internal difference between an AC and a DC contactor?
It's just a switch why wouldn't it work because of being DC?
And I need a contactor with a 48V DC coil preferably normally closed.
It's just a switch why wouldn't it work because of being DC?
And I need a contactor with a 48V DC coil preferably normally closed.
Was this review helpful? (0/0)
What kind of threads do DC contactors have?
quella
7/25/2023 12:10 AM
Alright, thank you for your response.
If the main contacts do not have female M5 threads, what kind of threads do they have?
If the main contacts do not have female M5 threads, what kind of threads do they have?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
200A High Voltage DC Contactor, 12V/24V coil
ATO-DCCON-HV200
$161.08
High voltage DC contactor, built-in energy saving coil, available with 12V or 24V DC, normally open type (SPST-NO), main contact rated load current is 200 amps, operating voltage up to 1000V, maximum switching power up to 640 kW.
50A DC Reversing Contactor, 2 pole, 12V/24V/48V
ATO-DCCON-R50
$74.31
Two pole DC reversing contacor with 2 sets of switching contacts, 2NO and 2NC form, 50 amps rated load current of contact circuit, coil rated voltage with 12V/24V/48V DC for selection. Cheap price and manufacturer direct sale.
DC Voltage Monitoring Relay, Under/Over Voltage, 12V/24V/48V DC
ATO-MR-DVRD
$105.98
DC voltage monitoring relay with 2 C/O contacts (2 Form C or DPDT) provide protection for the equipment from undervoltage and overvoltage in DC circuit 12V, 24V, 36V or 48V, adjustable trip delay time, LED indicator for working state, DIN rail mounting, compact design, good quality and low price.
100A DC Reversing Contactor, 2 pole, 12V/24V/48V
ATO-DCCON-R100
$126.46
Low cost reversing contacor with two interlocked contacts, to prevent the motor from running forwards and backwards simultaneously. 2 pole DC contactor with 2NO and 2NC (DPST-NO, DPST-NC) contact form, coil rated voltage with 12V/24V/48V DC for choice.
250A High Voltage DC Contactor, 12V/24V coil
ATO-DCCON-HV250
$179.54
250A rated load current, main contact normal open (SPST-NO), available with 12V or 24V DC coil, switch rated loads at both low and high voltage from 12 to 900V DC. High voltage contactors offers exceptional performance in an extremely small and lightweight device.