Voltage Monitoring Relay, Under/Over Voltage, 1 Phase, 110-240V AC/DC

$115.67
Single phase voltage monitoring relay, suitable for undervoltage and overvoltage monitoring of DC 12V, AC/DC 24-48V or AC/DC 110V-240V, adjustable delay time, compact size relay with 1 CO & 1 NC contacts, real-time LCD for voltage, operation and fault status display, DIN rail mounting, high quality and low cost.
SKU: ATO-MR-SVR1000
*
Free Shipping
Delivery date: 6-12 days

The AC/DC voltage monitoring relay with LCD display is a multifunctional monitoring and protection device. The relay is applied in supply voltage of DC 12V, AC/DC 24-48V or AC/DC 110V-240V to protect the equipment or devices from undervoltage and overvoltage in the applications like air compressors, electric motors, pumps, fans, air-conditioning system, blowers, elevators, cranes, refrigeration equipment, laser equipment, industrial control system, etc.

Features

  • Powered by the measuring circuit
  • Compatible with AC and DC supply
  • LCD display and keypad afford precise digital setting
  • Compact size in DIN rail mounting
  • Adjustable overvoltage and undervoltage threshold
  • Independent adjustable delay time for overvoltage, undervoltage
  • Adjustable reset mode: automatic reset or manual reset
  • Monitoring relay with 1 CO + 1 NC contacts
  • Fault recording for the last 3 faults

Specification

ModelATO-SVR1000/D12ATO-SVR1000/AD48ATO-SVR1000/AD220
Measuring CircuitAC/DC circuit (A1+, A2-)
Monitoring FunctionsOvervoltage, Undervoltage
Rated VoltageDC 12VAC/DC 24-48V 50/60HzAC/DC 110-240V 50/60Hz
Undervoltage Setting RangeDC 9-18V adjustableAC/DC 20-80V adjustableAC/DC 50-300V adjustable
Overvoltage Setting RangeDC 9-18V adjustableAC/DC 20-80V adjustableAC/DC 50-300V adjustable
Voltage Hysteresis0.1-6.0V adjustable0.1-30.0V adjustable1.0-90.0V adjustable
Delay Time for Overvoltage & Undervoltage0.1-999s adjustable
Reset ModeManual/Automatic/Automatic with power-on delay
Delay Time for Reset0.1-999s adjustable
IndicatorLCD display indicating voltage, operation and fault status
Fault RecordsThe last 3 faults
Output Contacts1 CO + 1 NC
Contact Capacity6A, 250V AC (resistive load)
Degree of ProtectionIP 20
CertificationCE
Working ConditionsOperating Temperature-25℃~65℃
Humidity≤85%RH, non-condensing
Mechanical Durability1,000,000 cycles
Dielectric Strength>2kVAC 1min
Mounting35mm DIN rail
Weight130g
Dimensions (H*W*D)80*43*54mm

Wiring Diagram

1-Phase Voltage AC Monitoring Relay Wiring Diagram

Note:
1. Relay contacts position shown in "Power-on" (Healthy) condition. If power is off or any fault occurs, the relay contacts will be opposite to the diagram.
2. For DC power, the polarities must be correctly connected. Otherwise, the relay doesn't work.

Details

Single Phase Voltage Monitoring Relay Details

Tips: Under/Over Voltage Monitoring Relay Function

The under/over voltage monitoring relay is used to automatically disconnect the circuit when the overvoltage and undervoltage in the line exceed the specified value and can automatically detect the line voltage, and it can automatically connect the circuit when the voltage in the line returns to normal, so as to protect our electricity safety.

The voltage monitoring relay is mainly used to protect the insulation of electrical equipment such as generators, transformers, vacuum switches, busbars, and motors from damage by overvoltage.

When the power supply line has overvoltage and under voltage, the voltage monitoring relay can quickly and safely cut off the circuit under continuous high-voltage impact to avoid the occurrence of accidents caused by abnormal voltage being sent to the terminal appliances. When the voltage returns to the normal value, the monitoring relay will automatically connect the circuit within the specified time to ensure that the terminal appliances are in normal operation under unattended duty.

3-Phase Monitoring Relay Phase Failure & Phase Sequence Testing

In this video, we will give you a test of ATO 3-phase monitoring relay on phase failure and phase sequence, and the relay does the job at such these cases to protect the motor. In addition, this multi-purpose monitoring relay has other monitoring functions such as undervoltage, overvoltage, voltage unbalance, timer & counter.

Working Principles 3-Phase Monitoring Relay 

3-phase Monitoring Relay Phase Failure and Sequence Test

In this video, the phase failure and sequence test of the 3-phase monitoring relay is introduced.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
What is the Aux. Power Supply voltage range?
5
Raymond
Avatar
11/24/2020 6:22 PM
Hi. For your DC under and overvoltage relay (ATO-MR-SVR1000), what is the Aux. Power Supply voltage range?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Raymond. There is no need for Aux. Power Supply, and the relay is directly connected to your circuit for using.
Can you suggest me a contactor to use with this voltage monitoring relay?
5
Alston
Avatar
5/24/2022 11:50 PM
I bought SVR1000\AD220 to use to cut off my solar array as protection for my inverter when voltage is too high. My inverter limit is 260V DC. From the string, I get a max amperage of 18 to 20A. Can you suggest me a contactor to use with SVR1000\AD220 and the current I have?
Was this review helpful? Yes No (0/0)
ATO Responded
What is the voltage rating of your solar array system? The maximum voltage of our DC contactor coil is 220VDC, we recommend you to use this model ATO-DCCON-80A, plz see spec and price on: https://www.ato.com/80-amp-dc-contactor
Voltage relay unit monitor
5
sera
Avatar
7/24/2023 9:17 PM
Can the ATO-MR-SVR1000 unit monitor a 3-phase system at 30-40 amps at 480 volts?
Was this review helpful? Yes No (0/0)
ATO Responded
ATO-MR-SVR1000 can only detect voltage, not current.
ATO-MR-SVR1000 can only pass a maximum current of 6A.
Screen display
5
Syrillic
Avatar
4/2/2025 7:42 PM
I would like to know if the voltage value can be displayed on the screen.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the voltage value can be displayed on the screen.
Usage Situation
4
Mohr
Avatar
9/4/2026 1:30 AM
Would your voltage monitoring relay (undervoltage/overvoltage protection, single-phase, 110-240V AC/DC) be suitable for my situation? My system consists of: a 120-150V DC generator charging at 8 amps; a 120-150V DC battery pack; and a 1000W DC offload load. If your relay contacts cannot handle such a high DC load, I can use another relay to control the offload load. I need to regulate the battery voltage to prevent overcharging and undercharging.
Was this review helpful? Yes No (0/0)
ATO Responded
This relay can only be used to monitor overvoltage and undervoltage. The relay contacts cannot handle high DC loads, and we have not tested it with a DC battery pack, so we are unsure if it suits your application. We suggest you purchase a unit for testing.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The AC/DC voltage monitoring relay with LCD display is a multifunctional monitoring and protection device. The relay is applied in supply voltage of DC 12V, AC/DC 24-48V or AC/DC 110V-240V to protect the equipment or devices from undervoltage and overvoltage in the applications like air compressors, electric motors, pumps, fans, air-conditioning system, blowers, elevators, cranes, refrigeration equipment, laser equipment, industrial control system, etc.

Features

  • Powered by the measuring circuit
  • Compatible with AC and DC supply
  • LCD display and keypad afford precise digital setting
  • Compact size in DIN rail mounting
  • Adjustable overvoltage and undervoltage threshold
  • Independent adjustable delay time for overvoltage, undervoltage
  • Adjustable reset mode: automatic reset or manual reset
  • Monitoring relay with 1 CO + 1 NC contacts
  • Fault recording for the last 3 faults

Specification

ModelATO-SVR1000/D12ATO-SVR1000/AD48ATO-SVR1000/AD220
Measuring CircuitAC/DC circuit (A1+, A2-)
Monitoring FunctionsOvervoltage, Undervoltage
Rated VoltageDC 12VAC/DC 24-48V 50/60HzAC/DC 110-240V 50/60Hz
Undervoltage Setting RangeDC 9-18V adjustableAC/DC 20-80V adjustableAC/DC 50-300V adjustable
Overvoltage Setting RangeDC 9-18V adjustableAC/DC 20-80V adjustableAC/DC 50-300V adjustable
Voltage Hysteresis0.1-6.0V adjustable0.1-30.0V adjustable1.0-90.0V adjustable
Delay Time for Overvoltage & Undervoltage0.1-999s adjustable
Reset ModeManual/Automatic/Automatic with power-on delay
Delay Time for Reset0.1-999s adjustable
IndicatorLCD display indicating voltage, operation and fault status
Fault RecordsThe last 3 faults
Output Contacts1 CO + 1 NC
Contact Capacity6A, 250V AC (resistive load)
Degree of ProtectionIP 20
CertificationCE
Working ConditionsOperating Temperature-25℃~65℃
Humidity≤85%RH, non-condensing
Mechanical Durability1,000,000 cycles
Dielectric Strength>2kVAC 1min
Mounting35mm DIN rail
Weight130g
Dimensions (H*W*D)80*43*54mm

Wiring Diagram

1-Phase Voltage AC Monitoring Relay Wiring Diagram

Note:
1. Relay contacts position shown in "Power-on" (Healthy) condition. If power is off or any fault occurs, the relay contacts will be opposite to the diagram.
2. For DC power, the polarities must be correctly connected. Otherwise, the relay doesn't work.

Details

Single Phase Voltage Monitoring Relay Details

Tips: Under/Over Voltage Monitoring Relay Function

The under/over voltage monitoring relay is used to automatically disconnect the circuit when the overvoltage and undervoltage in the line exceed the specified value and can automatically detect the line voltage, and it can automatically connect the circuit when the voltage in the line returns to normal, so as to protect our electricity safety.

The voltage monitoring relay is mainly used to protect the insulation of electrical equipment such as generators, transformers, vacuum switches, busbars, and motors from damage by overvoltage.

When the power supply line has overvoltage and under voltage, the voltage monitoring relay can quickly and safely cut off the circuit under continuous high-voltage impact to avoid the occurrence of accidents caused by abnormal voltage being sent to the terminal appliances. When the voltage returns to the normal value, the monitoring relay will automatically connect the circuit within the specified time to ensure that the terminal appliances are in normal operation under unattended duty.

Product reviews
What is the Aux. Power Supply voltage range?
5
Raymond
Avatar
11/24/2020 6:22 PM
Hi. For your DC under and overvoltage relay (ATO-MR-SVR1000), what is the Aux. Power Supply voltage range?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Raymond. There is no need for Aux. Power Supply, and the relay is directly connected to your circuit for using.
Can you suggest me a contactor to use with this voltage monitoring relay?
5
Alston
Avatar
5/24/2022 11:50 PM
I bought SVR1000\AD220 to use to cut off my solar array as protection for my inverter when voltage is too high. My inverter limit is 260V DC. From the string, I get a max amperage of 18 to 20A. Can you suggest me a contactor to use with SVR1000\AD220 and the current I have?
Was this review helpful? Yes No (0/0)
ATO Responded
What is the voltage rating of your solar array system? The maximum voltage of our DC contactor coil is 220VDC, we recommend you to use this model ATO-DCCON-80A, plz see spec and price on: https://www.ato.com/80-amp-dc-contactor
Voltage relay unit monitor
5
sera
Avatar
7/24/2023 9:17 PM
Can the ATO-MR-SVR1000 unit monitor a 3-phase system at 30-40 amps at 480 volts?
Was this review helpful? Yes No (0/0)
ATO Responded
ATO-MR-SVR1000 can only detect voltage, not current.
ATO-MR-SVR1000 can only pass a maximum current of 6A.
Screen display
5
Syrillic
Avatar
4/2/2025 7:42 PM
I would like to know if the voltage value can be displayed on the screen.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the voltage value can be displayed on the screen.
Usage Situation
4
Mohr
Avatar
9/4/2026 1:30 AM
Would your voltage monitoring relay (undervoltage/overvoltage protection, single-phase, 110-240V AC/DC) be suitable for my situation? My system consists of: a 120-150V DC generator charging at 8 amps; a 120-150V DC battery pack; and a 1000W DC offload load. If your relay contacts cannot handle such a high DC load, I can use another relay to control the offload load. I need to regulate the battery voltage to prevent overcharging and undercharging.
Was this review helpful? Yes No (0/0)
ATO Responded
This relay can only be used to monitor overvoltage and undervoltage. The relay contacts cannot handle high DC loads, and we have not tested it with a DC battery pack, so we are unsure if it suits your application. We suggest you purchase a unit for testing.
Only registered users can write reviews
Customers who bought this item also bought

DC Voltage Monitoring Relay, Under/Over Voltage, 12V/24V/48V DC

ATO-MR-DVRD
$105.98
DC voltage monitoring relay with 2 C/O contacts (2 Form C or DPDT) provide protection for the equipment from undervoltage and overvoltage in DC circuit 12V, 24V, 36V or 48V, adjustable trip delay time, LED indicator for working state, DIN rail mounting, compact design, good quality and low price.

30A High Voltage DC Contactor, 12V/24V coil

ATO-DCCON-HV30
$87.23
Cheap Price DC contactor relay, normally open (SPST-NO) type, 30 amps rated load current of contact circuit, available with 12V or 24V coils. Magnetic contactor is widely used in the DC 12-900V high voltage field, offers exceptional performance in an extremely small and lightweight device.