Multifunctional Monitoring Relay, Line Voltage, 3 Phase, 208-480V AC

$158.23
Phase-phase voltage monitoring relay, used for phase loss, phase sequence, voltage unbalance, overvoltage and undervoltage monitoring with 3 phase power supplied by 208-480V AC 50/60Hz, also with timer & counter function, 0.1-30s adjustable delay time, compact size relay with 1 CO + 1 NC contacts, real-time LCD display for voltage, fault and operation state, DIN rail mounting. High accuracy and favorable price.
SKU: ATO-MR-JVR8002
Free Shipping
Delivery date: 6-12 days

Line voltage monitoring relay with LCD display is used to monitor phase loss, phase sequence, voltage unbalance, overvoltage and undervoltage in the 3-phase power supply of 208-480V AC 50/60Hz. The monitoring relay is widely applied in the applications like air compressors, electric motors, pumps, fans, air-conditioning system, blowers, lifts, elevators, cranes, refrigeration units, mining excavators and conveyors, etc.

Features

  • Compact size in DIN rail mounting
  • Microprocessor technology provides highly accurate and repeatable protection
  • LCD display and keypad afford a precise digital setting
  • Adjustable overvoltage and undervoltage,phase unbalance threshold
  • Independent adjustable delay time for overvoltage, undervoltage, voltage unbalance, phase loss and phase sequence
  • Adjustable reset method: automatic reset or manual reset
  • Start delay (power-on delay)
  • Test trip with test button
  • Monitoring relay with 1 CO & 1 NC contacts
  • With timer and counter for running and faults

Specification

ModelATO-JVR800-2
Measuring Circuit3-Phase AC: L1, L2, L3
Monitoring FunctionsPhase Sequence (Reversal), Phase Loss (Failure)
Overvolatege, Undervoltage, Voltage Unbalance (Asymmetry)
Timer & Counter
Rated Voltage208-480V AC, 50/60Hz
Overvoltage Setting Range200-600V
Undervoltage Setting Range150-500V
Voltage Hysteresis1-20V
Delay Time for Overvoltage & Undervoltage0.1-30s
Voltage Unbalance Ratio1-50%
Voltage Unbalance Hysteresis1-10%
Delay Time for Voltage Unbalance0.1-30s
Delay Time for Phase Loss0.1-30s
Delay Time for Phase Sequence0.1-30s
Power On Delay Time0-999s
Reset ModeManual/Auto
Delay Time for Reset0.1-999s
Timer and Counter InputAC/DC 80-450V
IndicatorLCD display indicating voltage, fault and operation status
Output Contacts1 CO + 1 NC
Contact Capacity6A, 250V AC (resistive load)
Degree of ProtectionIP 20
CertificationCE
Working ConditionsOperating Temperature-25℃~65℃
Humidity≤85%RH, non-condensing
Mechanical Durability1,000,000 cycles
Dielectric Strength>2kVAC 1min
Mounting35mm DIN rail
CertificationCE
Weight130g
Dimensions (H*W*D)80*43*54mm

Wiring Diagram Multifunctional Phase Voltage Monitoring Relay Wiring Diagram

Monitoring relay contacts position shown in "Power-on" (Healthy) condition

Dimensions (Unit: mm)

Multifunctional Phase Voltage Monitoring Relay Dimension

Details

Three Phase Voltage  Monitoring Relay Details

Tips: Phase Failure and Phase Sequence Monitoring Relay Function

Generally, the wiring order of the motor is specified. If the phase sequence is disordered due to some reason, the motor will not work properly or even be damaged. Phase sequence monitoring relay is to prevent such accidents. Phase sequence protection can use phase sequence monitoring relays. When the phase sequence in the circuit does not match the specified phase sequence, the phase sequence relay will trigger the action and cut off the power of the control circuit to achieve the purpose of cutting off the motor power and protecting the motor.

Phase failure protection relay, or motor phase failure protector is generally used in three-phase motor circuits. If one line circuit is missing, the motor torque will become smaller and the rotor speed will decrease, resulting in the increasing current of other two circuits and the motor winding burning. The principle of phase failure monitoring relay is to monitor the three-phase power through different means: if there is a circuit break, the power will be automatically cut off by the relay to avoid burning the winding. Nowadays, the methods of phase-loss protection is to control the circuit on and off by monitoring the voltage of each channel or monitoring the current of each channel.

In the video below, ATO will use the ATO-MR-JVR8002 Multifunctional Monitoring Relay to monitor the three phase loss and reverse phase sequence when the 3-phase induction motor is running.

3-Phase Monitoring Relay Phase Failure & Phase Sequence Testing

In this video, we will give you a test of ATO 3-phase monitoring relay on phase failure and phase sequence, and the relay does the job at such these cases to protect the motor. In addition, this multi-purpose monitoring relay has other monitoring functions such as undervoltage, overvoltage, voltage unbalance, timer & counter.

Working Principles 3-Phase Monitoring Relay 

3-phase Monitoring Relay Phase Failure and Sequence Test

In this video, the phase failure and sequence test of the 3-phase monitoring relay is introduced.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
These work great!
5
Nathan
Avatar
7/1/2021 7:11 AM
This phase monitoring works like a champ and is so easy to set up and program.  My customer is extremely happy they now have a digital solution instead of the old turn-style analog relays they had before.  Thank you ATO, for the fast shipping and great product!
Was this review helpful? Yes No (1/0)
Do I need relay CTS or an access line?
5
sini
Avatar
7/24/2023 3:41 AM
When using ATO-MR-JVR8002, do I need CTS or an access line?
Do I need a CTS when using the ATO-MR-JVR8002, or do I need wiring, and can it handle 25-40 amps?
Was this review helpful? Yes No (0/0)
ATO Responded
1. You need to access the wires.
2. AT-MR-JVR8002 detects voltage instead of current.
Question about phase
5
Clare
Avatar
10/24/2023 1:49 AM
Is it working with only 2 phases (2 x 120v inverted = 220v)?
Was this review helpful? Yes No (0/0)
ATO Responded
This unit can Not be used as a 2-phase unit, it can only be used as a 3-phase unit.
Grounded Delta
5
John
Avatar
12/10/2025 11:03 AM
Will this work / can this be configured for Grounded Delta (one phase at 0V)?

Are you OEM or reseller of this device?
Was this review helpful? Yes No (0/0)
ATO Responded
I don't quite understand what you're saying, but this product can be used for both Wye and delta types; however, in the Wye type, it also measures the line voltage (L+L). We are a major distributor and can provide OEM services.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Line voltage monitoring relay with LCD display is used to monitor phase loss, phase sequence, voltage unbalance, overvoltage and undervoltage in the 3-phase power supply of 208-480V AC 50/60Hz. The monitoring relay is widely applied in the applications like air compressors, electric motors, pumps, fans, air-conditioning system, blowers, lifts, elevators, cranes, refrigeration units, mining excavators and conveyors, etc.

Features

  • Compact size in DIN rail mounting
  • Microprocessor technology provides highly accurate and repeatable protection
  • LCD display and keypad afford a precise digital setting
  • Adjustable overvoltage and undervoltage,phase unbalance threshold
  • Independent adjustable delay time for overvoltage, undervoltage, voltage unbalance, phase loss and phase sequence
  • Adjustable reset method: automatic reset or manual reset
  • Start delay (power-on delay)
  • Test trip with test button
  • Monitoring relay with 1 CO & 1 NC contacts
  • With timer and counter for running and faults

Specification

ModelATO-JVR800-2
Measuring Circuit3-Phase AC: L1, L2, L3
Monitoring FunctionsPhase Sequence (Reversal), Phase Loss (Failure)
Overvolatege, Undervoltage, Voltage Unbalance (Asymmetry)
Timer & Counter
Rated Voltage208-480V AC, 50/60Hz
Overvoltage Setting Range200-600V
Undervoltage Setting Range150-500V
Voltage Hysteresis1-20V
Delay Time for Overvoltage & Undervoltage0.1-30s
Voltage Unbalance Ratio1-50%
Voltage Unbalance Hysteresis1-10%
Delay Time for Voltage Unbalance0.1-30s
Delay Time for Phase Loss0.1-30s
Delay Time for Phase Sequence0.1-30s
Power On Delay Time0-999s
Reset ModeManual/Auto
Delay Time for Reset0.1-999s
Timer and Counter InputAC/DC 80-450V
IndicatorLCD display indicating voltage, fault and operation status
Output Contacts1 CO + 1 NC
Contact Capacity6A, 250V AC (resistive load)
Degree of ProtectionIP 20
CertificationCE
Working ConditionsOperating Temperature-25℃~65℃
Humidity≤85%RH, non-condensing
Mechanical Durability1,000,000 cycles
Dielectric Strength>2kVAC 1min
Mounting35mm DIN rail
CertificationCE
Weight130g
Dimensions (H*W*D)80*43*54mm

Wiring Diagram Multifunctional Phase Voltage Monitoring Relay Wiring Diagram

Monitoring relay contacts position shown in "Power-on" (Healthy) condition

Dimensions (Unit: mm)

Multifunctional Phase Voltage Monitoring Relay Dimension

Details

Three Phase Voltage  Monitoring Relay Details

Tips: Phase Failure and Phase Sequence Monitoring Relay Function

Generally, the wiring order of the motor is specified. If the phase sequence is disordered due to some reason, the motor will not work properly or even be damaged. Phase sequence monitoring relay is to prevent such accidents. Phase sequence protection can use phase sequence monitoring relays. When the phase sequence in the circuit does not match the specified phase sequence, the phase sequence relay will trigger the action and cut off the power of the control circuit to achieve the purpose of cutting off the motor power and protecting the motor.

Phase failure protection relay, or motor phase failure protector is generally used in three-phase motor circuits. If one line circuit is missing, the motor torque will become smaller and the rotor speed will decrease, resulting in the increasing current of other two circuits and the motor winding burning. The principle of phase failure monitoring relay is to monitor the three-phase power through different means: if there is a circuit break, the power will be automatically cut off by the relay to avoid burning the winding. Nowadays, the methods of phase-loss protection is to control the circuit on and off by monitoring the voltage of each channel or monitoring the current of each channel.

In the video below, ATO will use the ATO-MR-JVR8002 Multifunctional Monitoring Relay to monitor the three phase loss and reverse phase sequence when the 3-phase induction motor is running.

Product reviews
These work great!
5
Nathan
Avatar
7/1/2021 7:11 AM
This phase monitoring works like a champ and is so easy to set up and program.  My customer is extremely happy they now have a digital solution instead of the old turn-style analog relays they had before.  Thank you ATO, for the fast shipping and great product!
Was this review helpful? Yes No (1/0)
Do I need relay CTS or an access line?
5
sini
Avatar
7/24/2023 3:41 AM
When using ATO-MR-JVR8002, do I need CTS or an access line?
Do I need a CTS when using the ATO-MR-JVR8002, or do I need wiring, and can it handle 25-40 amps?
Was this review helpful? Yes No (0/0)
ATO Responded
1. You need to access the wires.
2. AT-MR-JVR8002 detects voltage instead of current.
Question about phase
5
Clare
Avatar
10/24/2023 1:49 AM
Is it working with only 2 phases (2 x 120v inverted = 220v)?
Was this review helpful? Yes No (0/0)
ATO Responded
This unit can Not be used as a 2-phase unit, it can only be used as a 3-phase unit.
Grounded Delta
5
John
Avatar
12/10/2025 11:03 AM
Will this work / can this be configured for Grounded Delta (one phase at 0V)?

Are you OEM or reseller of this device?
Was this review helpful? Yes No (0/0)
ATO Responded
I don't quite understand what you're saying, but this product can be used for both Wye and delta types; however, in the Wye type, it also measures the line voltage (L+L). We are a major distributor and can provide OEM services.
Only registered users can write reviews
Customers who bought this item also bought

95 Amps 4 Pole AC Contactor 24V/110V/220V Coil

ATO-ACCON-095
$177.89
4 pole 95 amps AC contactor has 24V/110V/220V coil volatge available for selection. When used in AC-3 380V, the rated current of contactor relay is 95A, when used in AC-3 660V, rated current is 49A. With 4P (4NO) or 4P (2NO+2NC) contact form, economical price and high quanlity.