100A DC Contactor, 12V/24V/48V

$103.63
High performance 100A DC contactor with normally open or normally closed main contact type, and available with two optional auxiliary contacts. Coil rated voltage with 12V/24V/48V for selection, main contact voltage drop at 100A, not above 100mV.
SKU: ATO-DCCON-C100
*
Availability: In stock
Free Shipping
Delivery date: 2-12 days

The 100A contactor, normally open (NO) or normally closed (NC) contact form, has been designed for direct current loads, particularly for electric vehicles, telecommunication equipment, car batteries, trains, ships, and electronic control systems.

Features

  • The DC contactor has the characteristics of small size, large load capacity, long service life and simple maintenance, and is very popular among users.
  • 100 amps contactor complies with the requirements of the ministry standards JB2286-78, JB3974-85, YD/585-92, YD/T512-92. It has been tested in the factory and by relevant testing units and meets the requirements of the ministry standards. It has been used by users for many years to satisfy users to the maximum extent. Needed, reliable quality.
  • 100A DC contactors are suitable for electric forklifts, battery trucks, tractors, excavators, brick making machines, cleaning vehicles, automotive air conditioners, communication power supplies, switch control of electronic control circuits of uninterruptible power supplies, electroplating power supplies and other systems.

Specifications

ModelATO-SZJB100A-DATO-SZJ100A
Contact FormNormally Closed (NC)Normally Open (NO)
Coil Rated Voltage (DC V)12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V, 220V12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V
Contact Rated Voltage (DC V)≤60V
Contact 48V Circuit Rated Load Current (DC-1)100A
Main Contact Contact Voltage Drop Under 100A Load≤80mV
Cooling pull-in voltage (V), (20±5)℃≤70%
Cooling release operating voltage (V), (20±5)℃≤35%, ≥5%≤40%, ≥5%
40℃ Coil Operating Voltage Range0.8-1.2Us
Power-on Action Time10ms12ms
Power-off Release Time25ms8ms
Maximum Bounce Time of Contact Connection10ms
Maximum Bounce Time of Contact Disconnection3ms
Insulation Resistance20MΩ
Dielectric Strength50Hz/60Hz 1000VAC 1minute
Maximum Breaking Capacity of Main Contact (Power on for 5ms)800A/5ms at 48V DC600A/5ms at 48V DC
Coil Power Consumption (W)5-10Start: 120-170, Hold: 3-8
Coil Temperature Rise (K)≤80≤40
Terminal Temperature Rise (K)≤65
Electrical Life20000 times
Mechanical Life300,000 times
Work SpecificationsContinuous
Contact MaterialSilver Alloy
Load Terminal TypeM6 Screw
Coil Terminal TypeM4 Screw
Auxiliary Contact Rated Load (Optional)2A/48V DC, 5A/24V DC, One Open and One Closed
Testing Agency CertificationCCC, CE, FCC, RoHS


Load Characteristic Curve

100A load characteristic curve

Installation Dimension Diagram

100A DC contactor installation dimension drawing

Wiring Diagram & Temperature Rise Curve Graph

100A DC contactor wiring

100A DC contactor temperature rise curve graph

Mechanical Capabilities and Usage Environment

Contact Terminal M8 Tightening Torque (Nm)≯9.0 is appropriate
Coil Lead-out M4 Tightening Torque (Nm)≯1.2 is appropriate
Ambient Temperature-25~+70℃
Relative Humidity+20℃ 98%
Vibration Frequency at Fixed Location3G, 1~50Hz, amplitude 0.5mm
Impact(60~100) times/min, acceleration ≤4g
Altitude2000 meters
Installation DirectionArbitrary
Protection LevelIP40 (equivalent to IEC60947)

Tips: Contactor series and parallel connection

Many power consumption equipment are single-phase loads, therefore, several poles of the multipole contactor can be used in parallel, such as the electric resistance furnace, and welder transformer. When several poles are used in parallel, a small-capacity contactor can be selected. However, it has to be noticed that the heating current of the parallel contactor is not completely proportional to the number of parallel poles. Because the resistance value of moving and static contact loops may not be equal, thus the flowing current may not the averagely distributed. Therefore, the current could only be increased by 1.8 times for bipolar parallel and by 2~2.4 times for triode parallel.
Moreover, various polar contacts can't connect or disconnect at the same time after a parallel connection, so the connection and breaking ability can't be improved.
Sometimes, several contacts of the contactor can be used in series. Due to the increase of contact fracture, the arc is divided into many segments, thus improving the arc extinguishing ability and accelerating arc quenching. When several contactors are connected in series, the working voltage could be enhanced, but it can’t exceed the rated insulation voltage. Agreed heating current and rated working current of the contactor would not change after a series connection.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Works great
5
pribula
Avatar
3/7/2019 6:46 PM
It is simple to install this DC conductor if you have an electrical background. I bought this conductor for my motor home. 12 volt battery banks can put out a lot of current. You can also choose 24V or 48V to output as you need. It is a fair price for the quality!
Was this review helpful? Yes No (0/0)
The peak voltage
4
Medeo
Avatar
3/11/2025 2:33 AM
I would like to know whether ATO-AZJ100 can be used at a peak voltage of 50V?
Was this review helpful? Yes No (0/0)
ATO Responded
Regarding the question of whether ATO-AZJ100 can be used at a peak voltage of 50V, we do not recommend doing so. Because if a power supply with a peak voltage of 50V is used, the coil may be easily burned, thus affecting the performance and life of the product.
We’re impressed with its solid performance
5
Mason
Avatar
11/9/2025 10:46 PM
It handles high current smoothly with minimal voltage drop. The silver alloy contacts show no signs of arcing after months of use. Compact size fits perfectly in our battery enclosure. Solid performance for heavy-duty applications.
Was this review helpful? Yes No (0/0)
It's dependable and durable
5
Daniel
Avatar
11/17/2025 8:01 PM
This little contactor never lets me down. It handles daily bumps and rain without fail. So reliable and worry-free.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The 100A contactor, normally open (NO) or normally closed (NC) contact form, has been designed for direct current loads, particularly for electric vehicles, telecommunication equipment, car batteries, trains, ships, and electronic control systems.

Features

  • The DC contactor has the characteristics of small size, large load capacity, long service life and simple maintenance, and is very popular among users.
  • 100 amps contactor complies with the requirements of the ministry standards JB2286-78, JB3974-85, YD/585-92, YD/T512-92. It has been tested in the factory and by relevant testing units and meets the requirements of the ministry standards. It has been used by users for many years to satisfy users to the maximum extent. Needed, reliable quality.
  • 100A DC contactors are suitable for electric forklifts, battery trucks, tractors, excavators, brick making machines, cleaning vehicles, automotive air conditioners, communication power supplies, switch control of electronic control circuits of uninterruptible power supplies, electroplating power supplies and other systems.

Specifications

ModelATO-SZJB100A-DATO-SZJ100A
Contact FormNormally Closed (NC)Normally Open (NO)
Coil Rated Voltage (DC V)12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V, 220V12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V
Contact Rated Voltage (DC V)≤60V
Contact 48V Circuit Rated Load Current (DC-1)100A
Main Contact Contact Voltage Drop Under 100A Load≤80mV
Cooling pull-in voltage (V), (20±5)℃≤70%
Cooling release operating voltage (V), (20±5)℃≤35%, ≥5%≤40%, ≥5%
40℃ Coil Operating Voltage Range0.8-1.2Us
Power-on Action Time10ms12ms
Power-off Release Time25ms8ms
Maximum Bounce Time of Contact Connection10ms
Maximum Bounce Time of Contact Disconnection3ms
Insulation Resistance20MΩ
Dielectric Strength50Hz/60Hz 1000VAC 1minute
Maximum Breaking Capacity of Main Contact (Power on for 5ms)800A/5ms at 48V DC600A/5ms at 48V DC
Coil Power Consumption (W)5-10Start: 120-170, Hold: 3-8
Coil Temperature Rise (K)≤80≤40
Terminal Temperature Rise (K)≤65
Electrical Life20000 times
Mechanical Life300,000 times
Work SpecificationsContinuous
Contact MaterialSilver Alloy
Load Terminal TypeM6 Screw
Coil Terminal TypeM4 Screw
Auxiliary Contact Rated Load (Optional)2A/48V DC, 5A/24V DC, One Open and One Closed
Testing Agency CertificationCCC, CE, FCC, RoHS


Load Characteristic Curve

100A load characteristic curve

Installation Dimension Diagram

100A DC contactor installation dimension drawing

Wiring Diagram & Temperature Rise Curve Graph

100A DC contactor wiring

100A DC contactor temperature rise curve graph

Mechanical Capabilities and Usage Environment

Contact Terminal M8 Tightening Torque (Nm)≯9.0 is appropriate
Coil Lead-out M4 Tightening Torque (Nm)≯1.2 is appropriate
Ambient Temperature-25~+70℃
Relative Humidity+20℃ 98%
Vibration Frequency at Fixed Location3G, 1~50Hz, amplitude 0.5mm
Impact(60~100) times/min, acceleration ≤4g
Altitude2000 meters
Installation DirectionArbitrary
Protection LevelIP40 (equivalent to IEC60947)

Tips: Contactor series and parallel connection

Many power consumption equipment are single-phase loads, therefore, several poles of the multipole contactor can be used in parallel, such as the electric resistance furnace, and welder transformer. When several poles are used in parallel, a small-capacity contactor can be selected. However, it has to be noticed that the heating current of the parallel contactor is not completely proportional to the number of parallel poles. Because the resistance value of moving and static contact loops may not be equal, thus the flowing current may not the averagely distributed. Therefore, the current could only be increased by 1.8 times for bipolar parallel and by 2~2.4 times for triode parallel.
Moreover, various polar contacts can't connect or disconnect at the same time after a parallel connection, so the connection and breaking ability can't be improved.
Sometimes, several contacts of the contactor can be used in series. Due to the increase of contact fracture, the arc is divided into many segments, thus improving the arc extinguishing ability and accelerating arc quenching. When several contactors are connected in series, the working voltage could be enhanced, but it can’t exceed the rated insulation voltage. Agreed heating current and rated working current of the contactor would not change after a series connection.

Product reviews
Works great
5
pribula
Avatar
3/7/2019 6:46 PM
It is simple to install this DC conductor if you have an electrical background. I bought this conductor for my motor home. 12 volt battery banks can put out a lot of current. You can also choose 24V or 48V to output as you need. It is a fair price for the quality!
Was this review helpful? Yes No (0/0)
The peak voltage
4
Medeo
Avatar
3/11/2025 2:33 AM
I would like to know whether ATO-AZJ100 can be used at a peak voltage of 50V?
Was this review helpful? Yes No (0/0)
ATO Responded
Regarding the question of whether ATO-AZJ100 can be used at a peak voltage of 50V, we do not recommend doing so. Because if a power supply with a peak voltage of 50V is used, the coil may be easily burned, thus affecting the performance and life of the product.
We’re impressed with its solid performance
5
Mason
Avatar
11/9/2025 10:46 PM
It handles high current smoothly with minimal voltage drop. The silver alloy contacts show no signs of arcing after months of use. Compact size fits perfectly in our battery enclosure. Solid performance for heavy-duty applications.
Was this review helpful? Yes No (0/0)
It's dependable and durable
5
Daniel
Avatar
11/17/2025 8:01 PM
This little contactor never lets me down. It handles daily bumps and rain without fail. So reliable and worry-free.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

200A DC Contactor, 12V/24V/48V

ATO-DCCON-C200
$121.65
This 200 amps contactor is available in coil voltage 12V, 24V, 48V, continuous operating duty, normally open (NO) or normally closed (NC) contact form, high quality DC contactor with high-performance quality, low cost and manufacturer direct sale.

50 amp 3/4 Pole DC Coil Contactor, 12V/24V/48V/220V Coil

ATO-DCCON-50A
$156.92
50A 3 or 4 pole AC contactor is an electrical switching device with DC control to control electric motors, lighting and other electrical loads at 12V, 24V, 36V, 48V, 110V, 220V coil rated voltage. Rated power up to 37 kW, contact form 3 NO or 2NO+2NC for your choices.

50A DC Contactor, 12V/24V/48V

ATO-DCCON-C50
$102.61
High quality DC contactor with 12V, 24V, 36V and 48V coil voltage for choice, normally open or normally closed type, contact circuit rated load current of 50A, offers exceptional performance in an extremely small and lightweight device.

600A DC Contactor, 12V/24V/48V

ATO-DCCON-C600
$185.32
High current contactor, designed for DC loads, contact circuit rated load current is 600A, normally open (NO) or normally closed (NC) contact form which has excellent conductivity. Single pole contactor, cheap price and manufacturer direct sale.

DC Voltage Monitoring Relay, Under/Over Voltage, 12V/24V/48V DC

ATO-MR-DVRD
$105.98
DC voltage monitoring relay with 2 C/O contacts (2 Form C or DPDT) provide protection for the equipment from undervoltage and overvoltage in DC circuit 12V, 24V, 36V or 48V, adjustable trip delay time, LED indicator for working state, DIN rail mounting, compact design, good quality and low price.