I have come up with your product below:
Voltage Sensor
ATO-VOS-DC1000
Though, I have 2 questions:
1) I see there are several inputs for Voltage from 0V – 1000V. My first question is how can I select a range of fe150V?
In such case, what will the accuracy at low voltages fe 4V (I need accuracy of 2 decimals)?
Is there an option to switch between 2 ranges in one single sensor?
2) If I adjust the output range to 0-10V (this is my acceptable PLC input), what will be the output in case of reverse polarity connection? I really want to avoid a negative signal on my PLC input.
3 phase AC voltage transducer has measuring range of AC 10V/50V/100V/250V/300V to 500V.
Specification:
| Model | ATO-WB3U412U01 | ATO-WB3U414U01 |
| Shipping weight | 1kg | |
| Measuring range of input voltage * | 3 phase AC 0-10V ~ 0-500V | |
| Short-time overload | 2 times of nominal input voltage, 1s in duration, interval time 10s, repeat 10 times | |
| Linear measurement range | 0% ~ 120% measuring range | |
| Frequency range | 25Hz ~ 1kHz | |
| Input impedance | Ri=2/3(Ux*1kΩ/V) | |
| Output signal * | DC 0-5V | DC 0-20mA, 4-20mA |
| Power supply * | DC 12V±10%, 24V±10% | |
| Accuracy | 0.5%F.S. | |
| Load capacity | 5mA | 6V |
| Response time | ≤300ms | |
| Temperature drift | 250*10-6/℃ | 350*10-6/℃ |
| Static current | ≤8mA | Output 0-20mA: ≤12mA Output 4-20mA: ≤35mA |
| Isolation features | Isolation between input and output, output terminals provides power supply | |
| Isolation voltage | DC 2.5kV, 1min | |
| Work temperature | 0~50℃ | |
| Storage temperature | -25~+70℃ | |
| Protection class of housing | IP20 | |
| Mean time between failures | >50000h | |
| Housing material | Fire-retardant ABS | |
| Wiring | Terminal connection | |
| Installation | DIN rail (NS35/7.5, NS35/15, EN50022) | |
3 phase AC voltage transducer 10V to 500V dimensional drawing (unit: mm):
3 phase AC voltage transducer output 0-5V wiring diagram:
3 phase AC voltage transducer output 0-20mA/4-20mA wiring diagram:
Tips: Measuring requirements when using voltage sensors
To measure the voltage with a voltage sensor, it is generally required that the collected voltage signal is proportional to the measured voltage in amplitude, and the phase angles of the two are exactly the same or the difference is extremely small. In addition, there are the following basic requirements for the voltage sensor.
- The connection of the voltage sensor to the circuit under test should basically not affect the amplitude and waveform of the voltage under test.
- The voltage waveform obtained by the voltage sensor should be the same as the measured voltage waveform, and the voltage divider ratio should be independent of the measured voltage frequency and amplitude.
- The voltage divider ratio has nothing or basically nothing to do with atmospheric conditions (air pressure, temperature and humidity).
- The power consumed by the voltage sensor should not be large. Under certain cooling conditions, the temperature rise formed by the electrical energy dissipated by the voltage divider should not cause a change in the voltage divider ratio.
- The voltage sensor should not be interfered by the external electromagnetic field, and on the other hand, it should not produce strong electromagnetic interference from the external environment.
Product reviews
I want to buy your voltage sensor
Curtis
9/21/2021 9:26 PM
Was this review helpful? (0/0)
Works as expected
Walter
7/3/2025 4:08 PM
Great sensor, works as expected
Was this review helpful? (0/0)
Voltage measurement
Telis
7/9/2025 8:04 PM
I have a three-phase AC voltage sensor model ATO-WB3U412U01. Can this sensor provide phase-to-ground voltage measurement when only one phase is connected? Or can it only measure phase-to-phase voltage?
Was this review helpful? (1/0)
Maximum AC voltage
Bercy
1/13/2026 8:25 PM
We received a device with model number ATO-WB3U414U01_0.5. What is the maximum AC voltage of this device?
Was this review helpful? (0/0)
Performance below zero temperatures
Kenny
2/23/2026 11:41 PM
We purchased this 3-phase AC voltage transducer and want to know how it performs below zero temperatures. Will it break down or just experience a decrease in accuracy?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
AC Current Sensor, AC 200A/400A/600A/800A
ATO-CUS-AC800
$88.25
AC current sensor adopts electromagnetic isolation principle, small size, light weight, low price, fast response, high accuracy, good stability, 35mm/45mm/55mm hole diameter, and screws fixed installation. AC current sensor is widely used for AC current measurement of various occasions, especially for sine-wave ac current with power frequency 50Hz.
3 Phase AC Current Transducer 0.5A/1A/2A/5A/10A/20A/50A to 80A
ATO-CUS-3AC80
$161.39
AC current transducer is a special current sensor for 3 phase AC current measurement. Three phase current transducer adopts epoxy resin pouring sealant to ensure the stability of components, with 0.5%FS accuracy, three output signals 4-20mA/0-20mA/0-5V/0-10V, power supply DC 5V/12V/24V, fixed installation. 3 phase AC current transducer is widely used for real-time monitoring of power grid AC current.
DC Current Sensor 1mA/1A/5A/10A/100A to 800A
ATO-CUS-DC800
$85.56
DC current sensor has best cost performance, fast response, high accuracy, good stability, small size, light weight, DIN rail installation, widely used for DC current measurement of various occasions.
Isolated DC Voltage Sensor 10mV to 1000V, Power Supply DC 12V/24V
ATO-VOS-DC1000
$141.96
DC voltage sensor uses modulation and demodulation technology to achieve input/output/power supply isolation. Isolated voltage transducer has measuring range from DC 10mV/50mV/75mV/5V/150V/300V/500V to 1000V, supply voltage DC 12V/24V, accuracy 0.2%FS, output signal 0-5V/0-10V/0-20mA/4-20mA and strong anti-interference capability. DC voltage sensor is widely used for voltage isolated measuring and control, such as electric power, remote monitoring, medical equipment, etc.
AC/DC Voltage Sensor 75mV to 500V, RMS 0-5V/0-10V/4-20mA/0-20mA Output
ATO-VOS-ACDC500
$161.27
Voltage sensor has voltage measuring range from AC/DC 75mV/50V/100V/250V/300V to 500V, supply voltage DC 12V/24V, output DC voltage/current or True RMS voltage/current signal 0-5V/0-10V/0-20mA/4-20mA and protection class IP20. AC/DC voltage sensor has two installation methods, DIN rail installation and M3 screw fixation.