Split-core AC Current Sensor 400A/2000A/8000A/10000A to 20000A

$151.19
Hall effect AC current sensors have non-invasive structure, with 1.0%FS accuracy, 1ms fast response time, 0-400A ~ 0-20000A measuring range, 4-20mA output signal, 12V/24V power supply, excellent linearity and strong anti-interference capacity. Open loop AC current sensors can be connected to AD, DSP and PLC directly. AC current sensors are now widely used for high current measurement of control systems.
SKU: ATO-CUS-AC20000
*
*
Free Shipping
Delivery date: 8-12 days

AC current sensor has measuring range of 400A/1000A/2000A/5000/8000A/10000A/15000A to 20000A.

Specification:

ModelATO-AHKC-KDAATO-AHKC-HBDA
Shipping weight1kg
Hole size *64*16mm132*52mm
Measuring range of input current *AC 0-400A ~ 0-2000AAC 0-2000A ~ 0-20000A
Output signalDC 4-20mA
Zero offset current±0.05mA
Offset current drift±0.04mA/℃
Linearity≤0.2%FS
Power supply *DC 24V±10% or DC 12V±10%
Accuracy1.0%F.S.
Response time≤1ms
Withstand voltageAC 2500V (between input, output and power supply)
Work temperature-25~+70℃
Storage temperature-40~+85℃
Humidity≤95%RH (no dew formation, no corrosive gas)
Elevation≤3500m
Measuring methodSplit-core type
InstallationScrew fixation

400A to 20000A AC current sensor dimensional diagram:
400A/2000A/8000A/10000A to 20000A AC current sensor dimension

ModelDimension (mm)
WHDa
eN (Mounting)
ATO-AHKC-KDA1276325641630
ATO-AHKC-HBDA204111.5291325248*2

400A to 20000A AC current sensor wiring diagram:
400A/2000A/8000A/10000A to 20000A AC current sensor wiring diagram

Details

Split Core AC Current Sensor 400A to 20000A

Tips: Application of Hall current sensor in retrofit distribution system
Open-loop Hall effect current sensor is mainly used in factory transformation of DC distribution system, such as power plant DC power system transformation, substation DC system transformation, communication room transformation, railway locomotive transformation and other projects. It can transform the system original coil DC Current signal into a standard DC ±5V or 4-20mA output signal. It plays the role of monitoring and electrical isolation and can be used in conjunction with multi channels monitoring instruments or other electrical measuring instruments. DC system transformation without power outage, engineering transformation is very difficult. Using traditional closed core hall current sensor or shunt cannot be resolved, and so the split-core open-loop Hall current sensor could be used to solve the DC current metering problem, to ensure that it is not power outage and safe in the engineering transformation process.

Product reviews
Nice current sensor
5
Phoeby
Avatar
9/26/2021 2:50 AM
My audio amplifier doesn't have good ventilation in its current location. I used two Loops of wire through the core to sense the 0.6 amps of current of my audio amplifier. For the load, I used a small fan. Now whenever I turn on my amplifier, the cooling fan goes on, keeping it nice and cool.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

AC current sensor has measuring range of 400A/1000A/2000A/5000/8000A/10000A/15000A to 20000A.

Specification:

ModelATO-AHKC-KDAATO-AHKC-HBDA
Shipping weight1kg
Hole size *64*16mm132*52mm
Measuring range of input current *AC 0-400A ~ 0-2000AAC 0-2000A ~ 0-20000A
Output signalDC 4-20mA
Zero offset current±0.05mA
Offset current drift±0.04mA/℃
Linearity≤0.2%FS
Power supply *DC 24V±10% or DC 12V±10%
Accuracy1.0%F.S.
Response time≤1ms
Withstand voltageAC 2500V (between input, output and power supply)
Work temperature-25~+70℃
Storage temperature-40~+85℃
Humidity≤95%RH (no dew formation, no corrosive gas)
Elevation≤3500m
Measuring methodSplit-core type
InstallationScrew fixation

400A to 20000A AC current sensor dimensional diagram:
400A/2000A/8000A/10000A to 20000A AC current sensor dimension

ModelDimension (mm)
WHDa
eN (Mounting)
ATO-AHKC-KDA1276325641630
ATO-AHKC-HBDA204111.5291325248*2

400A to 20000A AC current sensor wiring diagram:
400A/2000A/8000A/10000A to 20000A AC current sensor wiring diagram

Details

Split Core AC Current Sensor 400A to 20000A

Tips: Application of Hall current sensor in retrofit distribution system
Open-loop Hall effect current sensor is mainly used in factory transformation of DC distribution system, such as power plant DC power system transformation, substation DC system transformation, communication room transformation, railway locomotive transformation and other projects. It can transform the system original coil DC Current signal into a standard DC ±5V or 4-20mA output signal. It plays the role of monitoring and electrical isolation and can be used in conjunction with multi channels monitoring instruments or other electrical measuring instruments. DC system transformation without power outage, engineering transformation is very difficult. Using traditional closed core hall current sensor or shunt cannot be resolved, and so the split-core open-loop Hall current sensor could be used to solve the DC current metering problem, to ensure that it is not power outage and safe in the engineering transformation process.

Product reviews
Nice current sensor
5
Phoeby
Avatar
9/26/2021 2:50 AM
My audio amplifier doesn't have good ventilation in its current location. I used two Loops of wire through the core to sense the 0.6 amps of current of my audio amplifier. For the load, I used a small fan. Now whenever I turn on my amplifier, the cooling fan goes on, keeping it nice and cool.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

DC Current Sensor 50A/100A/200A/500A/1000A to 1500A

ATO-CUS-DC1500
$83.25
Hall effect DC current sensors are open loop current sensors, with split-core structure, 1ms fast response time, 1.0%FS accuracy, 4-20mA output signal, 12V/24V power supply, fixed installation, excellent linearity and strong anti-interference capacity. DC current sensors are widely used for DC current monitoring, system signal acquisition and feedback control.