125 hp (90 kW) Soft starter, 180 A, 3ph 220v/380v/460v

$1,168.42
Inexpensive 125 hp soft starter, 90 kW three phase 220v, 380v, 460v AC motor starter, control motor in soft start & soft stop, buy it from Chinese manufacturer directly.
SKU: GS-090
Free Shipping
Delivery date: 6-12 days

125 hp motor soft starter, 90 kW three phase 220v, 380v, 460v, 690v AC motor soft starter.

ModelGS2-090 (220v, 240v), GS3-090 (380v, 400v, 415v), GS4-090 (460v, 480v), GS6-090 (575v, 690v).
Capacity125 hp (90 kw)
Current180 amps at 380v/480v, 400 amps at 220v, 110 amps at 690v
Weight21 kg
Dimension270*146*160 mm
InputVoltageThree-phase 220v, 380v, 460v, 660v AC
Frequency50Hz/ 60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
485 CommunicationDB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureEnclosureIP 20
CoolingNatural wind cooling.

Details

90KW Soft Starters Details

Tips: Daily maintenance and inspection of soft starters
Check the environmental conditions of the soft starter to prevent it from operating beyond its permissible ambient conditions. Check whether object is obstructing the ventilation and heat dissipation around the soft starter, and ensure that there is sufficient space around the soft starter (greater than 150mm).
Check whether the distribution wire terminals are loose regularly, and whether the components in the cabinet are overheated, discoloring and burnt with a burnt taste.
Clean the dust regularly so as not to affect the heat dissipation, prevent the SCR from being damaged due to high temperature, and avoid leakage and short circuit accidents caused as dirt retention.
The dust can be cleaned away with a dry brush, or blown with bellows and sucked with dust collector. The massive dirt can be removed with insulating rod. If conditions permit, it can be scavenged with 0.6MPa compressed air.
Observe the operation of the fan at ordinary times, once the fan speed is slow or abnormal, it shall be promptly repaired (such as cleaning oil dirt and dust, adding lubricants, replacing the damaged or degenerative capacitor). Damaged fans shall be replaced in time. If the soft starter is sued without a fan, SCR may be damaged.
If the soft starter is sued in an environment that is humid or easy to condense, it shall be dried with infrared light bulbs or electric hair drier, in order to avoid leakage or short circuit accident.

Soft Starter Works with a Bypass Contactor

Soft starter works with a bypass contactor saving energy by eliminating thyristor losses during the run. The bypass contactor shunts the current flowing through the soft starter switch circuit to reduce heat accumulation in the soft starter power electronics during motor operation. This provides maximum efficiency and prolongs the life of soft-start switching components because they only work during the start and stop cycles of the motor.

How to Change the Soft Starter Rated Current

Delayed Soft Start of A Motor

In this video, we introduce how to use a soft starter together with a bypass contactor to achieve a delayed soft start of a motor.

Product reviews
Practical 125hp soft starter
5
Rachlin
Avatar
6/28/2021 3:07 AM
This 125hp (90kW) soft starter works well on fans and pumps. Moreover, its starting current is small, which reduces the trip probability of my car. It is highly recommended that you buy this 125 hp (90kW) soft starter from the ATO.com online store.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

125 hp motor soft starter, 90 kW three phase 220v, 380v, 460v, 690v AC motor soft starter.

ModelGS2-090 (220v, 240v), GS3-090 (380v, 400v, 415v), GS4-090 (460v, 480v), GS6-090 (575v, 690v).
Capacity125 hp (90 kw)
Current180 amps at 380v/480v, 400 amps at 220v, 110 amps at 690v
Weight21 kg
Dimension270*146*160 mm
InputVoltageThree-phase 220v, 380v, 460v, 660v AC
Frequency50Hz/ 60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
485 CommunicationDB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureEnclosureIP 20
CoolingNatural wind cooling.

Details

90KW Soft Starters Details

Tips: Daily maintenance and inspection of soft starters
Check the environmental conditions of the soft starter to prevent it from operating beyond its permissible ambient conditions. Check whether object is obstructing the ventilation and heat dissipation around the soft starter, and ensure that there is sufficient space around the soft starter (greater than 150mm).
Check whether the distribution wire terminals are loose regularly, and whether the components in the cabinet are overheated, discoloring and burnt with a burnt taste.
Clean the dust regularly so as not to affect the heat dissipation, prevent the SCR from being damaged due to high temperature, and avoid leakage and short circuit accidents caused as dirt retention.
The dust can be cleaned away with a dry brush, or blown with bellows and sucked with dust collector. The massive dirt can be removed with insulating rod. If conditions permit, it can be scavenged with 0.6MPa compressed air.
Observe the operation of the fan at ordinary times, once the fan speed is slow or abnormal, it shall be promptly repaired (such as cleaning oil dirt and dust, adding lubricants, replacing the damaged or degenerative capacitor). Damaged fans shall be replaced in time. If the soft starter is sued without a fan, SCR may be damaged.
If the soft starter is sued in an environment that is humid or easy to condense, it shall be dried with infrared light bulbs or electric hair drier, in order to avoid leakage or short circuit accident.

Product reviews
Practical 125hp soft starter
5
Rachlin
Avatar
6/28/2021 3:07 AM
This 125hp (90kW) soft starter works well on fans and pumps. Moreover, its starting current is small, which reduces the trip probability of my car. It is highly recommended that you buy this 125 hp (90kW) soft starter from the ATO.com online store.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

200 hp (150 kW) Soft starter, 300 A, 3ph 240v/400v/480v

GS-150
$1,379.53
Low price 200 hp soft starter, 150 kW 3 phase 240v, 400v, 480v, 690v motor starter, control AC induction motor in soft start & soft stop, buy from China manufacturer directly.