80A DC Contactor, single pole, 12V/24V/48V

$114.36
80A rated current DC contactor has one normally open contact (SPST-NO), single pole, available anyway to install, coil rated voltage with 12V/24V/48V DC for choice.
SKU: ATO-DCCON-C80
*
Free Shipping
Delivery date: 6-12 days

ATO-ANR80 single pole DC contactor with normal open contact (SPST-NO), used for battery, rectification power supply, pump motor, and other electronic vehicles.

80A DC Contactor Features

  • 80 amps rated load current of contact circuit.
  • 12V, 24V, 48V DC coil-rated voltage for selection.
  • The allowed range of coil voltage is ±20%.
  • 2A/48VDC and 5A/24VDC auxiliary contact-rated load to choose.
  • Mechanical life up to 300 thousand times.

80A DC Contactor Specifications

BasicsModelATO-ANR80
Body Size75*55*82 mm
Weight210 g
Technical ParametersCoil Rated Voltage12V/24V/48V
Rated Load Voltage12~72V DC
Contact Circuit Rated Load Current80 A
Contact Form1 NO
Overload Current≤7 le
Coil Power4-10 W
Main Contact Voltage Drop at 100A Load≤100 mV
The Allowed Range of Coil Voltage±20%
Pull-In Time (N/O Contacts to Open)≤30 ms
Drop-Out Time (N/O Contact to Close)≤20 ms
Insulation Resistance≥50 MΩ
Dielectric Withstanding Voltage50Hz/60Hz 1500VAC/Min
Electric LifeContinuous 20000 times
Mechanical Life300 thousand times
EnvironmentOperating Temperature-25℃~55℃
Operating Humidity5~95% RH
International ProtectionIP 50

80A DC Contactor Installation Diagram (Unit: mm)

80A DC contactor dimension

Tips: The contactor coil is overheated or burned down

Possible causes of the fault:

  • The supply voltage is too high.
  • The contactor is frequently operated.
  • At high ambient temperature, the end face of the contactor's iron core is not smooth.
  • There's a mechanical failure on the contactor's movable iron core, which makes the iron core unable to suck, turn-to-turn short circuit.

Maintenance method:

  1. Measure whether the working voltage on the contactor conforms to the rated voltage of the contactor coil, if it's too high or too low, adjust it to the normal voltage value.
  2. Improve the temperature of the working environment, and strengthen heat dissipation.
  3. Clean and wipe the end face of the contactor iron core, replace the iron core when necessary.
  4. Check if the mechanical part of the contactor moves flexibly, replace a same type coil after repairing if the coil has been burned out.
  5. Eliminate the reasons for causing mechanical damage of the contactor coil, replace the coil.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Contactor worked great
5
Cory Kent
Avatar
1/7/2020 6:44 PM
I ordered two of these contactors for a project and they both worked great. Thanks for quick delivery and I would buy again from the same vendor.
Was this review helpful? Yes No (0/0)
Satisfied with its quality
5
Mina
Avatar
3/10/2026 7:24 PM
The 80A DC contactor is robust and reliable, easy to install, and handles high currents smoothly. Six months in, not a single instance of contact welding.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

ATO-ANR80 single pole DC contactor with normal open contact (SPST-NO), used for battery, rectification power supply, pump motor, and other electronic vehicles.

80A DC Contactor Features

  • 80 amps rated load current of contact circuit.
  • 12V, 24V, 48V DC coil-rated voltage for selection.
  • The allowed range of coil voltage is ±20%.
  • 2A/48VDC and 5A/24VDC auxiliary contact-rated load to choose.
  • Mechanical life up to 300 thousand times.

80A DC Contactor Specifications

BasicsModelATO-ANR80
Body Size75*55*82 mm
Weight210 g
Technical ParametersCoil Rated Voltage12V/24V/48V
Rated Load Voltage12~72V DC
Contact Circuit Rated Load Current80 A
Contact Form1 NO
Overload Current≤7 le
Coil Power4-10 W
Main Contact Voltage Drop at 100A Load≤100 mV
The Allowed Range of Coil Voltage±20%
Pull-In Time (N/O Contacts to Open)≤30 ms
Drop-Out Time (N/O Contact to Close)≤20 ms
Insulation Resistance≥50 MΩ
Dielectric Withstanding Voltage50Hz/60Hz 1500VAC/Min
Electric LifeContinuous 20000 times
Mechanical Life300 thousand times
EnvironmentOperating Temperature-25℃~55℃
Operating Humidity5~95% RH
International ProtectionIP 50

80A DC Contactor Installation Diagram (Unit: mm)

80A DC contactor dimension

Tips: The contactor coil is overheated or burned down

Possible causes of the fault:

  • The supply voltage is too high.
  • The contactor is frequently operated.
  • At high ambient temperature, the end face of the contactor's iron core is not smooth.
  • There's a mechanical failure on the contactor's movable iron core, which makes the iron core unable to suck, turn-to-turn short circuit.

Maintenance method:

  1. Measure whether the working voltage on the contactor conforms to the rated voltage of the contactor coil, if it's too high or too low, adjust it to the normal voltage value.
  2. Improve the temperature of the working environment, and strengthen heat dissipation.
  3. Clean and wipe the end face of the contactor iron core, replace the iron core when necessary.
  4. Check if the mechanical part of the contactor moves flexibly, replace a same type coil after repairing if the coil has been burned out.
  5. Eliminate the reasons for causing mechanical damage of the contactor coil, replace the coil.
Product reviews
Contactor worked great
5
Cory Kent
Avatar
1/7/2020 6:44 PM
I ordered two of these contactors for a project and they both worked great. Thanks for quick delivery and I would buy again from the same vendor.
Was this review helpful? Yes No (0/0)
Satisfied with its quality
5
Mina
Avatar
3/10/2026 7:24 PM
The 80A DC contactor is robust and reliable, easy to install, and handles high currents smoothly. Six months in, not a single instance of contact welding.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews