ATO 200A high voltage DC contactors with 12v or 24v coils, are widely used in the DC high voltage field, such as electric cars, hybrid electric vehicles, fuel cell vehicles, construction machinery, photovoltaic power generation, wind power generation, battery charging systems, DC power supply control system.
Features
- DC 1000V rated load voltage of contact circuit.
- Normally open type (SPST-NO) of contact form.
- The main contact voltage drops at 200A, not above 100mV.
- The connection of contact and coil needs to be nonpolarity.
- Efficient coil, retentive power is only 2-2.3W, counter electromotive force is 0V.
- The joint way of the coil is very convenient.
- The coil has no counterforce of electromagnetism.
- Compared to similar products, this product is the smallest and lightest.
Specifications
| Basics | Model | ATO-ADH200 |
| Dimension | 80 x 65 x 72 mm | |
| Weight | 480 g | |
| Main Contact Parameters | Contact Form | 1 NO |
| Leading-Out | M8 Internal thread | |
| Rated Load Current | 200 A | |
| Maximum Switching Voltage | 1000V DC | |
| Maximum Switching Current | 2000A 320V DC (≥1 times) | |
| Maximum Switching Power | 640 kW | |
| Auxiliary Contact Parameters | Aux. Contact Type | 1NO/1NC/1CO |
| Rated Current | 5A | |
| Maximum Breaking Voltage | 120V DC | |
| Coil Parameters | Standard Type Voltage | 12/24V DC |
| Work Voltage | 8~36V | |
| Max Voltage | 36 V | |
| Coil Resistance | 3.1Ω | |
| Average Holding Current | 0.14 A | |
| Steady State Power | 1.7~2 W | |
| Actuation Time | ≤30 ms | |
| Release Time | ≤10 ms | |
| Bounce Time | ≤5 ms | |
| Mechanical Specification | Stability | 196 m/s2 (20G) |
| Strength | 490 m/s2 (50G) | |
| Vibration | 80 ~2000Hz 98m/s2 (20G) | |
| IP Grade | IP67 | |
| Environment | Operating Temperature | -40℃~85℃ |
| Operating Humidity | 5~95% RH |
Installation Diagram (Unit: mm)
High Voltage DC Contactor Coil Schematic
Details

Tips: Why AC contactor and DC contactor can not be used interchangeably?
- AC contactor can be used to replace DC contactor in emergency, however, the pick-up time can't exceed 2 hours (Because the heat dissipation of AC coils is poorer than the DC coils, this is determined by their different structures.) If the AC contactor would be used for a long time, a resistance had better to be connect with the AC coil in series. Conversely, the DC contactor can’t be used to replace AC contactor.
- AC contactor has fewer turns while DC contactor has more, which can be distinguished from the volume of coils. If the current is too large in the main circuit (such as Ie>250), the contactor shall adopt a series duplex winding coil. The reactance of the coils of a DC contactor is large and the current is small. When it is connected with an AC, it will not break. However, coils of an AC contactor have small reactance and large current, so when the coils are connected with a DC, they will be damaged.
- AC contactor has fewer turns and smaller resistance, when the coils are connected with an AC, a larger inductance will be produced, which is far greater than the coil resistance, excitation current of the coils is mainly determined by the inductance. If the coils are connected with a DC, then the coils will become a pure resistance load, the current flowing through the coil will be quite large, which may heat the coils, or even burn the coils. So, the AC contactor can’t be used as a DC contactor.
Product reviews
My question about 200A DC contactor
Daveu
7/28/2021 12:11 AM
Is your 200A DC contactor driven with DC or PWM? Are both coils driven from 1 input, or are the 2 inputs separate?
Was this review helpful? (0/0)
Reliable DC contactor
Dean
8/11/2026 7:28 PM
We have been using this 200A high voltage DC contactor for our battery management system for several weeks. The switching is stable, the coil consumes very little power, and the sealed design helps protect it in a harsh environment. So far, it has performed well.
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
100A High Voltage DC Contactor, 12V/24V coil
ATO-DCCON-HV100
$118.92
The ATO-ADH100 contactor is specially design to meet the requirements of high voltage DC switching applications. Available with 12V or 24V coils, SPST-NO contact form, 100A rated load current of contact circuit, DC 12-900V rated load voltage.
600A DC Contactor, 12V/24V/48V
ATO-DCCON-C600
$185.32
High current contactor, designed for DC loads, contact circuit rated load current is 600A, normally open (NO) or normally closed (NC) contact form which has excellent conductivity. Single pole contactor, cheap price and manufacturer direct sale.
500A DC Contactor, single pole, 12V/24V/48V
ATO-DCCON-C500
$205.63
500A high current contactor with single pole, designed for direct current loads, IP 50 protection, good quality and long life. They are available with two optional auxiliary contacts, 2A/48V DC or 5A/24V DC.
100A DC Reversing Contactor, 2 pole, 12V/24V/48V
ATO-DCCON-R100
$126.46
Low cost reversing contacor with two interlocked contacts, to prevent the motor from running forwards and backwards simultaneously. 2 pole DC contactor with 2NO and 2NC (DPST-NO, DPST-NC) contact form, coil rated voltage with 12V/24V/48V DC for choice.
50A High Voltage DC Contactor, 12V/24V coil
ATO-DCCON-HV50
$111.85
High voltage DC contactor, normally open type (SPST-NO), 50 amps rated load current of contact circuit, available with 12V or 24V coils, the connection of contact and coil need to be nonpolarity. It is widely used in the DC high voltage field, such as electric car, wind power generation, DC power supply control system and so on.