ModelATO-ADC500-I
Coil Rated Voltage (Optional)12V/24V/48V
Rated Current12A
Contact Form (Optional)2NO, 2NC
Pole2 Pole
Contact Resistance≤30mΩ
Contact Voltage Drop≤80mV (at 80A)
Insulation Resistance≥50mΩ
Overload Current≤4le, >1s
Pull-in Voltage≤70%Us
Release Voltage5%-40%Us
Load Terminal TypeM6 External Thread
Working StyleShort Term
Load Endurance (Resistive) α≥20000 Times
Load Wiring Torque8-10N.m
Coil Wiring Torque0.5-0.8N.m
Vibration3.5g, 10~200Hz, 1/2 Sine Wave (Energized)
Temperature-40℃~85℃
Humidity5%~95%RH
Contact Bounce Time≤5ms
Pick-up Time≤30ms
Release Time≤30ms
Medium Pressure ResistanceBetween Main Contact50Hz/60Hz, 1500VAC/1min
Between Main Contact and Coil50Hz/60Hz, 1500VAC/1min
Insulation ResistanceInitial State100mΩ, 1min
After Electrical Life50mΩ, 1min
ImpactStability20g (power on)
Strength50g
Mechanical Durability≥1000000 Times
Dimension86mm*5Imm*78mm


Coil Parameter

Coil VoltagePull-in VoltageRelease VoltageCoil ResistanceCoil Power Consumption
12V≤70%Us5%-40%Us6Ω±10%24W±10%
24V≤70%Us5%-40%Us24Ω±10%24W±10%
36V≤70%Us5%-40%Us54Ω±10%24W±10%
48V≤70%Us5%-40%Us96Ω±10%24W±10%
60V≤70%Us5%-40%Us150Ω±10%24W±10%
72V≤70%Us5%-40%Us216Ω±10%24W±10%


Dimension (Unit: mm)

500A DC reversing contactor dimension

Wiring Diagram

500A DC reversing contactor wiring diagram

Applications

DC reversing contactor applications

Tips: DC reverse contactor applications

DC reverse contactors are widely used in many fields, mainly where the direction of DC motors needs to be controlled. Common application areas include:

  • Electric vehicles and rail transit: In electric vehicles and electric vehicles, reverse contactors are used to control the forward and reverse rotation of the motor to achieve the forward and reverse functions of the vehicle. Trains in rail transit also use reverse contactors to control their running direction.
  • Industrial automation: In industrial production lines, DC reverse contactors are used to drive and control various DC motors to achieve forward and reverse motion of mechanical equipment, such as conveyor belts, elevators, etc.
  • Renewable energy systems: In solar and wind power generation systems, reverse contactors are used to control the direction of current flow to optimize power transmission and storage efficiency.
  • Battery management system: In large-scale energy storage systems and battery management, reverse contactors are used to switch the direction of current, manage the charge and discharge process, and improve system reliability.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

500A 2 pole DC reversing contactor is used to change the direction of rotation in alternating current motors, start them gently and monitor their load, widely used in auto electric winches, telecommunication equipment, engineering machinery and other electric control systems.

Specification

ModelATO-ADC500-I
Coil Rated Voltage (Optional)12V/24V/48V
Rated Current12A
Contact Form (Optional)2NO, 2NC
Pole2 Pole
Contact Resistance≤30mΩ
Contact Voltage Drop≤80mV (at 80A)
Insulation Resistance≥50mΩ
Overload Current≤4le, >1s
Pull-in Voltage≤70%Us
Release Voltage5%-40%Us
Load Terminal TypeM6 External Thread
Working StyleShort Term
Load Endurance (Resistive) α≥20000 Times
Load Wiring Torque8-10N.m
Coil Wiring Torque0.5-0.8N.m
Vibration3.5g, 10~200Hz, 1/2 Sine Wave (Energized)
Temperature-40℃~85℃
Humidity5%~95%RH
Contact Bounce Time≤5ms
Pick-up Time≤30ms
Release Time≤30ms
Medium Pressure ResistanceBetween Main Contact50Hz/60Hz, 1500VAC/1min
Between Main Contact and Coil50Hz/60Hz, 1500VAC/1min
Insulation ResistanceInitial State100mΩ, 1min
After Electrical Life50mΩ, 1min
ImpactStability20g (power on)
Strength50g
Mechanical Durability≥1000000 Times
Dimension86mm*5Imm*78mm


Coil Parameter

Coil VoltagePull-in VoltageRelease VoltageCoil ResistanceCoil Power Consumption
12V≤70%Us5%-40%Us6Ω±10%24W±10%
24V≤70%Us5%-40%Us24Ω±10%24W±10%
36V≤70%Us5%-40%Us54Ω±10%24W±10%
48V≤70%Us5%-40%Us96Ω±10%24W±10%
60V≤70%Us5%-40%Us150Ω±10%24W±10%
72V≤70%Us5%-40%Us216Ω±10%24W±10%


Dimension (Unit: mm)

500A DC reversing contactor dimension

Wiring Diagram

500A DC reversing contactor wiring diagram

Applications

DC reversing contactor applications

Tips: DC reverse contactor applications

DC reverse contactors are widely used in many fields, mainly where the direction of DC motors needs to be controlled. Common application areas include:

  • Electric vehicles and rail transit: In electric vehicles and electric vehicles, reverse contactors are used to control the forward and reverse rotation of the motor to achieve the forward and reverse functions of the vehicle. Trains in rail transit also use reverse contactors to control their running direction.
  • Industrial automation: In industrial production lines, DC reverse contactors are used to drive and control various DC motors to achieve forward and reverse motion of mechanical equipment, such as conveyor belts, elevators, etc.
  • Renewable energy systems: In solar and wind power generation systems, reverse contactors are used to control the direction of current flow to optimize power transmission and storage efficiency.
  • Battery management system: In large-scale energy storage systems and battery management, reverse contactors are used to switch the direction of current, manage the charge and discharge process, and improve system reliability.
Only registered users can write reviews
Customers who bought this item also bought

25A SSR Solid State Relay, 3-32V DC to DC, Din Rail Mount

ATO-SSR-DS25DD
$72.73
25A Single phase slim SSR solid state relay with heat sink, DC to DC control, din rail mount, input 3-32VDC, output 3-75VDC. High reliability, high efficiency and long lifespan. Widely used in many automatic control systems.