200A DC Reversing Contactor, 2 pole, 12V/24V/48V

$164.46
Contact circuit rated current 200 amps, 2 pole DC contactor with 12V/24V/48V coil for choice, DPST-NO, DPST-NC contact form, two interlocked contacts are designed to prevent the motor from running forwards and backwards simultaneously.
SKU: ATO-DCCON-R200
*
Free Shipping
Delivery date: 6-12 days

ATO ADC200 reversing contactor is used to change the direction of rotation in alternating current motors, start them gently and to monitor their load. Widely used in auto electric winch, telecommunication equiment, engineering machinery and other electric control system.

Features

  • 200 amps rated load current of contact circuit.
  • 2NO and 2NC contact form.
  • 12V, 24V, 48V DC coil rated voltage for selection.
  • Main contact voltage drop at 100A, not above 100mV.
  • Mechanical life up to 300 thousand times.

Specifications

BasicsModelATO-ADC200
Body Size127*73*120 mm
Weight1760 g
Technical ParametersCoil Rated Voltage12V/24V/48V
Rated Load Voltage12~60V DC
Contact Circuit Rated Load Current200 A
Contact Form2NO and 2NC
Starting Current≤4 A
Overload Current≤7 le
Coil Power≤11 W
Main Contact Voltage Drop at 100A Load≤100 mV
The Allowed Range of Coil Voltage±20%
Pull-In Time (N/O Contacts to Open)≤30 ms
Drop-Out Time (N/O Contact to Close)≤20 ms
Insulation Resistance≥50 MΩ
Dielectric Withstanding Voltage50Hz/60Hz 1500VAC/Min
Electric LifeContinuous 20000 times
Mechanical Life300 thousand times
EnvironmentEnvironmental ProctectionIP 50
Operating Temperature-25℃~55℃
Operating Humidity5~95% RH

DC Reversing Contactor Circuit Diagram
dc reversing contactor circuit diagramInstallation Diagram (Unit: mm)
dc reversing contactor 200a dimension

Details

200A DC Reversing Contactor Details

Tips: Differences between AC contactor and DC contactor

  1. Different iron core: The iron core of an AC contactor is laminated by the insulated silicon steel sheets, which is in a double E shape; The iron core of an DC contactor is made from a whole soft iron, which is in a U shape.
  2. Different arc-extinguishing system: The AC contactor mainly adopts a splitter arc-extinguishing while the DC contactor adopts a magnetic quenching device.
  3. Different turns: AC contactor has fewer turns that are connected with the AC while DC contactor has more turns that are connected with DC. On-off of AC contactor is controlled by AC while that of DC contactor is controlled by DC. Highest operation frequency of AC contactor is 600 times per hour, the cost is low; while that of DC contactor could be as high as 2000 times per hour, the cost is high.

DC Reversing Contactor for DC Motor Forward/Reverse Control
The reversing type of DC contactor has been designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks. In this video, ATO will show you how to use a DC reversing contactor for the DC motor forward and reverse control.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Would like to buy 50A and 200A DC Reversing Contactors
5
Hendry
Avatar
6/27/2019 9:42 PM
We have forwarded the requirement to our purchase team, they will contact you for purchase of ADC50 and ADC200. Do you supply any arrangement for providing isolation between the terminals of the contactor (ADC50 and ADC200)? So that the lugs connected to the terminals never come in contact with each other.
Was this review helpful? Yes No (0/0)
ATO Responded
Don't provide isolation protection between terminals. But We recommend to cover your terminals with protective silicone.
Good price contactor, delivered earlier than expected
5
Evadman
Avatar
12/23/2020 6:23 PM
I bought 2 of these 200A  DC reversing contactor, they were delivered earlier than expected. Exact original replacement part for my Toro Mower. Easy to install and works great. I will be using this company for all my Toro Mower replacement parts from now on.
Was this review helpful? Yes No (0/0)
Can the 200A DC reversing contactor work continuously?
5
Melo
Avatar
7/19/2021 9:42 PM
Can your DC reversing contactor be used for continuous duty?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can be used for continuous duty.
Choosing contactor
5
Adela
Avatar
7/22/2024 3:09 AM
I have a DC 150AMP power supply for plating purpose. The highest load is 70Amp for 3 minutes. What contactor can be used?
Was this review helpful? Yes No (0/0)
ATO Responded
According to what you said, the highest load is 70Amp for 3 minutes. You can use our ADC200 contactor normally.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

ATO ADC200 reversing contactor is used to change the direction of rotation in alternating current motors, start them gently and to monitor their load. Widely used in auto electric winch, telecommunication equiment, engineering machinery and other electric control system.

Features

  • 200 amps rated load current of contact circuit.
  • 2NO and 2NC contact form.
  • 12V, 24V, 48V DC coil rated voltage for selection.
  • Main contact voltage drop at 100A, not above 100mV.
  • Mechanical life up to 300 thousand times.

Specifications

BasicsModelATO-ADC200
Body Size127*73*120 mm
Weight1760 g
Technical ParametersCoil Rated Voltage12V/24V/48V
Rated Load Voltage12~60V DC
Contact Circuit Rated Load Current200 A
Contact Form2NO and 2NC
Starting Current≤4 A
Overload Current≤7 le
Coil Power≤11 W
Main Contact Voltage Drop at 100A Load≤100 mV
The Allowed Range of Coil Voltage±20%
Pull-In Time (N/O Contacts to Open)≤30 ms
Drop-Out Time (N/O Contact to Close)≤20 ms
Insulation Resistance≥50 MΩ
Dielectric Withstanding Voltage50Hz/60Hz 1500VAC/Min
Electric LifeContinuous 20000 times
Mechanical Life300 thousand times
EnvironmentEnvironmental ProctectionIP 50
Operating Temperature-25℃~55℃
Operating Humidity5~95% RH

DC Reversing Contactor Circuit Diagram
dc reversing contactor circuit diagramInstallation Diagram (Unit: mm)
dc reversing contactor 200a dimension

Details

200A DC Reversing Contactor Details

Tips: Differences between AC contactor and DC contactor

  1. Different iron core: The iron core of an AC contactor is laminated by the insulated silicon steel sheets, which is in a double E shape; The iron core of an DC contactor is made from a whole soft iron, which is in a U shape.
  2. Different arc-extinguishing system: The AC contactor mainly adopts a splitter arc-extinguishing while the DC contactor adopts a magnetic quenching device.
  3. Different turns: AC contactor has fewer turns that are connected with the AC while DC contactor has more turns that are connected with DC. On-off of AC contactor is controlled by AC while that of DC contactor is controlled by DC. Highest operation frequency of AC contactor is 600 times per hour, the cost is low; while that of DC contactor could be as high as 2000 times per hour, the cost is high.
Product reviews
Would like to buy 50A and 200A DC Reversing Contactors
5
Hendry
Avatar
6/27/2019 9:42 PM
We have forwarded the requirement to our purchase team, they will contact you for purchase of ADC50 and ADC200. Do you supply any arrangement for providing isolation between the terminals of the contactor (ADC50 and ADC200)? So that the lugs connected to the terminals never come in contact with each other.
Was this review helpful? Yes No (0/0)
ATO Responded
Don't provide isolation protection between terminals. But We recommend to cover your terminals with protective silicone.
Good price contactor, delivered earlier than expected
5
Evadman
Avatar
12/23/2020 6:23 PM
I bought 2 of these 200A  DC reversing contactor, they were delivered earlier than expected. Exact original replacement part for my Toro Mower. Easy to install and works great. I will be using this company for all my Toro Mower replacement parts from now on.
Was this review helpful? Yes No (0/0)
Can the 200A DC reversing contactor work continuously?
5
Melo
Avatar
7/19/2021 9:42 PM
Can your DC reversing contactor be used for continuous duty?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can be used for continuous duty.
Choosing contactor
5
Adela
Avatar
7/22/2024 3:09 AM
I have a DC 150AMP power supply for plating purpose. The highest load is 70Amp for 3 minutes. What contactor can be used?
Was this review helpful? Yes No (0/0)
ATO Responded
According to what you said, the highest load is 70Amp for 3 minutes. You can use our ADC200 contactor normally.
Only registered users can write reviews
Customers who bought this item also bought

50A DC Reversing Contactor, 2 pole, 12V/24V/48V

ATO-DCCON-R50
$74.31
Two pole DC reversing contacor with 2 sets of switching contacts, 2NO and 2NC form, 50 amps rated load current of contact circuit, coil rated voltage with 12V/24V/48V DC for selection. Cheap price and manufacturer direct sale.

125A DC Reversing Contactor, 2 pole, 12V/24V/48V

ATO-DCCON-R125
$132.41
Excellent conductivity reversing contacor is designed for demanding forward/reverse control of the motors. 2 pole DC contactor with 12V/24V/48V coil, 2NO and 2NC contact form, and is available with two optional auxiliary contacts.

400A DC Reversing Contactor, 2 pole, 12V/24V/48V

ATO-DCCON-R400
$257.08
2 pole reversing contactor has been designed for direct current load, 2NO and 2NC ( DPST-NO, DPST-NC) contact form, rated load current is 400A. IP 50 protection, easy and quick installation, manufacturer direct sale.

2 Position 20A Rotary Switch, 4 Pole

ATO-LW26GS20
$59.13
Selector switch 2 position for sale, 20 amp samll rotary cam switch, 4 pole, rated voltage 440V, mainly applied to AC 50 Hz, rotary switch is ideal for power switches in power lines, rotary selector switch design, easy to control, easy to install square plate.