400A DC Reversing Contactor, 2 pole, 12V/24V/48V

$257.08
2 pole reversing contactor has been designed for direct current load, 2NO and 2NC ( DPST-NO, DPST-NC) contact form, rated load current is 400A. IP 50 protection, easy and quick installation, manufacturer direct sale.
SKU: ATO-DCCON-R400
*
Free Shipping
Delivery date: 10-20 days

ATO ASW400 reversing contactor is used to change the direction of rotation in alternating current motors, start them gently and to monitor their load. Widely used in auto electric winch, telecommunication equiment, engineering machinery and other electric control system.

Features

  • 400 amps rated load current of contact circuit.
  • 2NO and 2NC contact form.
  • 12V, 24V, 48V DC coil rated voltage for selection.
  • Main contact voltage drop at 100A, not above 100mV.
  • Mechanical life up to 300 thousand times.

400A DC Reversing Contactor Specifications

BasicsModelATO-ASW400-2Z
Body Size51*114*160 mm
Weight3150 g
Technical ParametersCoil Rated Voltage12V/24V/48V
Rated Load Voltage12~60V DC
Contact Circuit Rated Load Current400 A
Contact Form2NO and 2NC
Overload Current≤7 le
Coil Power≤24 W
Main Contact Voltage Drop at 100A Load≤100 mV
The Allowed Range of Coil Voltage±20%
Pull-In Time (N/O Contacts to Open)≤30 ms
Drop-Out Time (N/O Contact to Close)≤20 ms
Insulation Resistance≥50 MΩ
Dielectric Withstanding Voltage50Hz/60Hz 1000VAC/Min
Auxiliary Contact Rated Load (Option)2A/48VDC, 5A/24VDC
Electric LifeContinuous 20000 times
Mechanical Life300 thousand times
EnvironmentEnvironmental ProctectionIP 50
Operating Temperature-25℃~55℃
Operating Humidity5~95% RH

DC Reversing Contactor Circuit Diagram
dc reversing contactor circuit diagramInstallation Diagram (Unit: mm)

dc reversing contactor 400a dimension

Details

400A DC Reversing Contactor Details

Tips: Reasons for the contacts of contactor being unable to separate after powering off

  1. Control line of the coil is too long, the residual voltage is too large due to the influence of lead capacitance, which is enough to maintain a close situation for the iron core. As a result, the contacts can't be separated.
  2. Coil of the contactor has burnt out, deformed coil skeleton seizes the movable iron core, which makes it unable to move, thus the contacts can't be separated.
  3. The contact has been fused.
  4. The contactor has auto-lock function, and the function is normal.

DC Reversing Contactor for DC Motor Forward/Reverse Control
The reversing type of DC contactor has been designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks. In this video, ATO will show you how to use a DC reversing contactor for the DC motor forward and reverse control.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Best price, work perfectly
5
Stephen
Avatar
5/21/2018 7:54 PM
I purchased three of these contacors, they work perfectly for my projects. Best price as well, will buy again as needed.
Was this review helpful? Yes No (0/0)
Very impressed with the quality of this 400 amp dc contactor
5
Arlo Hopkins
Avatar
10/9/2018 7:24 PM
Very impressed with the quality of this 400 amp dc contactor. It easy to use and dose not take up much room, has lasted a long time with no problems.
Was this review helpful? Yes No (0/0)
400A DC reversing contactor worked fine
5
Darel Palm
Avatar
11/27/2018 2:02 AM
The DC reversing contactor worked fine, but after replacing it, my winch still didn't work. Found out it was corroded battery terminals that was causing the problem. Cleaned them up and it worked. Only complaint would be that it is a little pricey.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

ATO ASW400 reversing contactor is used to change the direction of rotation in alternating current motors, start them gently and to monitor their load. Widely used in auto electric winch, telecommunication equiment, engineering machinery and other electric control system.

Features

  • 400 amps rated load current of contact circuit.
  • 2NO and 2NC contact form.
  • 12V, 24V, 48V DC coil rated voltage for selection.
  • Main contact voltage drop at 100A, not above 100mV.
  • Mechanical life up to 300 thousand times.

400A DC Reversing Contactor Specifications

BasicsModelATO-ASW400-2Z
Body Size51*114*160 mm
Weight3150 g
Technical ParametersCoil Rated Voltage12V/24V/48V
Rated Load Voltage12~60V DC
Contact Circuit Rated Load Current400 A
Contact Form2NO and 2NC
Overload Current≤7 le
Coil Power≤24 W
Main Contact Voltage Drop at 100A Load≤100 mV
The Allowed Range of Coil Voltage±20%
Pull-In Time (N/O Contacts to Open)≤30 ms
Drop-Out Time (N/O Contact to Close)≤20 ms
Insulation Resistance≥50 MΩ
Dielectric Withstanding Voltage50Hz/60Hz 1000VAC/Min
Auxiliary Contact Rated Load (Option)2A/48VDC, 5A/24VDC
Electric LifeContinuous 20000 times
Mechanical Life300 thousand times
EnvironmentEnvironmental ProctectionIP 50
Operating Temperature-25℃~55℃
Operating Humidity5~95% RH

DC Reversing Contactor Circuit Diagram
dc reversing contactor circuit diagramInstallation Diagram (Unit: mm)

dc reversing contactor 400a dimension

Details

400A DC Reversing Contactor Details

Tips: Reasons for the contacts of contactor being unable to separate after powering off

  1. Control line of the coil is too long, the residual voltage is too large due to the influence of lead capacitance, which is enough to maintain a close situation for the iron core. As a result, the contacts can't be separated.
  2. Coil of the contactor has burnt out, deformed coil skeleton seizes the movable iron core, which makes it unable to move, thus the contacts can't be separated.
  3. The contact has been fused.
  4. The contactor has auto-lock function, and the function is normal.
Product reviews
Best price, work perfectly
5
Stephen
Avatar
5/21/2018 7:54 PM
I purchased three of these contacors, they work perfectly for my projects. Best price as well, will buy again as needed.
Was this review helpful? Yes No (0/0)
Very impressed with the quality of this 400 amp dc contactor
5
Arlo Hopkins
Avatar
10/9/2018 7:24 PM
Very impressed with the quality of this 400 amp dc contactor. It easy to use and dose not take up much room, has lasted a long time with no problems.
Was this review helpful? Yes No (0/0)
400A DC reversing contactor worked fine
5
Darel Palm
Avatar
11/27/2018 2:02 AM
The DC reversing contactor worked fine, but after replacing it, my winch still didn't work. Found out it was corroded battery terminals that was causing the problem. Cleaned them up and it worked. Only complaint would be that it is a little pricey.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

200A DC Reversing Contactor, 2 pole, 12V/24V/48V

ATO-DCCON-R200
$164.46
Contact circuit rated current 200 amps, 2 pole DC contactor with 12V/24V/48V coil for choice, DPST-NO, DPST-NC contact form, two interlocked contacts are designed to prevent the motor from running forwards and backwards simultaneously.

DC-DC Buck Converter, 24V to 12V

ATO-DCDC-2412
$102.58
24V to 12V mini DC-DC buck converter series is a compact size high reliability power converter with low price. This buck module features wide input voltage 18V to 36V, wide range power from 18 watts to 1200 watts, low power consumption. Industry grade step down converter, efficiency up to 97%.