150kVA 3-Phase 400v 50Hz/208v 60Hz Frequency Converter

$34,716.39
150 kVA static frequency converter, step up & step down 3-phase 208v/220v/380v/415v/480v power source, easy converting 50Hz to 60Hz (vice versa), make international 50/60 Hz power system compatible easily.
SKU: HZ-50-33150
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

150 kVA 3 phase 220V 60 Hz to 400V, 380V 50 Hz static frequency converter, adjustable output Hertz (40.0 Hz - 400 Hz) and Volt (0 - 520V), convert fixed power supply to variable-frequency and variable-voltage.

Specification:

ModelHZ-50-33150
Capacity150 kVA
Dimension1500*860*1430 mm
Weight800 kg
InputVoltage3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V ±10% (option *)
3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% (option *)
3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10% (option *)
Frequency50 Hz, 60 Hz
OutputVoltage, current110V Setting (Low grade): 0-150V (phase voltage), 0-260V (line voltage) 418A
220V Setting (High grade): 0-300V (phase voltage), 0-520V (line voltage) 209A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
-When the output is 400Hz, the load capacity can only reach 50% of the rated capacity.
-When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
-You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months

How to Test a 9V Transformer Power Supply in a Frequency Converter?

This video shows you how to use a multimeter to test the IGBT in a frequency converter.

How to Use a Multimeter to Test the IGBT in a Frequency Converter?

This video shows you how to use a multimeter to test the IGBT in a frequency converter.

How to Check the Fuse of a Frequency Converter?

In this video, the steps on how to check the fuse of a frequency converter using a multimeter are shown.

Product reviews
Failure analysis of 150kVA frequency converter
5
Thien
Avatar
4/12/2021 9:43 PM
What will happen to the 150kVA frequency converter if it got sudden high inrush/surge current?
Was this review helpful? Yes No (1/0)
ATO Responded
If the frequency converter got a sudden high inrush current, its internal protection trips, so you just need to reset and run again, not an issue.
I want a frequency converter that meets our requirements
5
Nycgal
Avatar
8/31/2021 12:15 AM
We need your brief specs for GoHz model HZ-50-1310 frequency converter with 1ph, 230V input, and 3-phase, 115V, 400Hz output?
Was this review helpful? Yes No (1/0)
ATO Responded
Ok, frequency converter model: HZ-50-1310, 10kVA power capacity, input: 1ph, 230V (+/- 10%), 50/60Hz and output: 3ph, Wye/Delta (L1,L2,L3 + N,G ), adjustable (0-260V), adjusted (40-499.9Hz), 27.6A.
I am interested in your frequency converter
5
Smiel
Avatar
9/23/2021 7:05 PM
20kVA 3-Phase 380v 50Hz/220v 60Hz Frequency Converter
1) From your description I found that it has 3-phase 400V (3x230V)/50Hz input and 3-phase 220V(3x120V)/60Hz output. So on the output there are L1, L2, L3 (3x120V) and N available? Please confirm..
2) Do you have any office sales in Europe? What is the cost of delivery to Poland?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Yes, as listed on the aforementioned specs.
2. Do not have office sales in Europe, but we are used to shipping to Poland Airport >>> Shipping cost (by Air): 681.01USD.
Frequency converter performance and use
5
Gotta
Avatar
9/26/2021 7:10 PM
Hi, I have a site in Australia. We build air conditioning units for other countries and want to test the units. Looking for a converter that can convert 240v 50Hz to 120v 60Hz but also gave a variant on the 120v side, so the voltage can be varied. Is this something you could assist with?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can.
Our converter output voltage and frequency can be adjusted in the range (0-150V) & (40-120Hz).
What is the tested air conditioning unit rated current (Amps), and power capacity? Also, what is its expected increase in current at the starting period?
Clarification: When the motor starts to spin up, it pulls high inrush current that may reach 6 times its rated value and lasts from few milliseconds to 1-3 seconds unless the motor is attached to starting controller like soft starter or VFD.
Which frequency converter would you recommend to us?
5
Fredrik
Avatar
10/11/2021 8:16 PM
We build boats and ship them to Europe regularly and they need to test the systems on the boats. We need to go from 120V 60Hz to 240V 50Hz. Currently they are using a generator to obtain the 50Hz, but it has been unreliable at best. They estimate the range to be between 30-50 Amps, possibly less. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your specs, recommended frequency converter model: HZ-50-1120, 20kVA power capacity, input: 1ph, 120V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable ( 0-300V), adjustable (40-120Hz), 83.2A.
I need a frequency converter. Do you have any recommendations?
5
Denali
Avatar
10/20/2021 8:11 PM
I need a frequency converter with:
Input: 400V, 50hz, three phase.
Output: 220V/110V 60Hz. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, recommended frequency converter model: HZ-50-3320, 20kVA power capacity, input: 3ph, Wye (L1, L2, L3 + N, G), 400V (+/- 10%), 50/60Hz and output: 3ph, Wye/Delta (L1, L2, L3 + N, G), adjustable (0-260V), adjustable (40-120Hz), 55.6A.
We need the following frequency converter specs
5
Lhaas
Avatar
1/11/2022 6:17 PM
We need the following converter specs: frequency converter, 400V/3phase/50Hz to 230v/3phase/60Hz and the capacity must be 40 kW and 100 Amps. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your specs, recommended frequency converter model: HZ-50-3360, 60kVA power capacity, input: 3ph, Wye (L1, L2, L3 + N, G), 400V (+/- 10%), 50/60Hz and output: 3ph, Wye/Delta (L1, L2, L3 + N, G), adjustable (0-260V), adjustable (40-120Hz), 166.4A.
Can you reproduce the documentation for this frequency converter?
5
berg
Avatar
6/13/2023 2:04 AM
I hope you have been well. I am reaching out because we are starting to use the equipment from this order in short order after some unforeseen delays.
Unfortunately, during the delay the manuals/documents and CE declaration of conformity seem to have been misplaced.
Is there any way you could reproduce the documentation for this unit for us? I would really appreciate it.
Thank you very much.
Was this review helpful? Yes No (0/0)
ATO Responded
Please check the attached user manual and factory test report.
You can refer to our demo video, please see on: https://www.youtube.com/watch?v=xRDzC1vHtIw
High efficiency converter
5
Phillip
Avatar
5/7/2024 3:17 AM
The company recently purchased a number of converters, management took this purchase quite seriously and asked a couple questions. The first was whether there were any lower voltage range converters available? For example: One rated 0-150V per phase instead of 0-300V. Also, would this converter be able to help couple the converter with a power conditioner, or use a harmonic filter after the converter?
Was this review helpful? Yes No (0/0)
ATO Responded
1.Is the rated 0-150V per phase you mentioned phase voltage or line voltage? Our converter's low-end voltage 0-150V is the phase voltage, and the corresponding line voltage range is 0-260VAC. It can be understood as you want the line voltage 0-260V?
2.Regarding the problem of harmonic interference, the vibration problem of the motor can Not be solved by adding a filter to the output end of the converter. Because we have tested similar loads, this is related to the motor speed and can Not be solved by simply adding a filter. We are still looking for ways to solve the vibration problem of this motor at low voltage and high speed.
Thanks for the question.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

150 kVA 3 phase 220V 60 Hz to 400V, 380V 50 Hz static frequency converter, adjustable output Hertz (40.0 Hz - 400 Hz) and Volt (0 - 520V), convert fixed power supply to variable-frequency and variable-voltage.

Specification:

ModelHZ-50-33150
Capacity150 kVA
Dimension1500*860*1430 mm
Weight800 kg
InputVoltage3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V ±10% (option *)
3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% (option *)
3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10% (option *)
Frequency50 Hz, 60 Hz
OutputVoltage, current110V Setting (Low grade): 0-150V (phase voltage), 0-260V (line voltage) 418A
220V Setting (High grade): 0-300V (phase voltage), 0-520V (line voltage) 209A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
-When the output is 400Hz, the load capacity can only reach 50% of the rated capacity.
-When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
-You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months

Product reviews
Failure analysis of 150kVA frequency converter
5
Thien
Avatar
4/12/2021 9:43 PM
What will happen to the 150kVA frequency converter if it got sudden high inrush/surge current?
Was this review helpful? Yes No (1/0)
ATO Responded
If the frequency converter got a sudden high inrush current, its internal protection trips, so you just need to reset and run again, not an issue.
I want a frequency converter that meets our requirements
5
Nycgal
Avatar
8/31/2021 12:15 AM
We need your brief specs for GoHz model HZ-50-1310 frequency converter with 1ph, 230V input, and 3-phase, 115V, 400Hz output?
Was this review helpful? Yes No (1/0)
ATO Responded
Ok, frequency converter model: HZ-50-1310, 10kVA power capacity, input: 1ph, 230V (+/- 10%), 50/60Hz and output: 3ph, Wye/Delta (L1,L2,L3 + N,G ), adjustable (0-260V), adjusted (40-499.9Hz), 27.6A.
I am interested in your frequency converter
5
Smiel
Avatar
9/23/2021 7:05 PM
20kVA 3-Phase 380v 50Hz/220v 60Hz Frequency Converter
1) From your description I found that it has 3-phase 400V (3x230V)/50Hz input and 3-phase 220V(3x120V)/60Hz output. So on the output there are L1, L2, L3 (3x120V) and N available? Please confirm..
2) Do you have any office sales in Europe? What is the cost of delivery to Poland?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Yes, as listed on the aforementioned specs.
2. Do not have office sales in Europe, but we are used to shipping to Poland Airport >>> Shipping cost (by Air): 681.01USD.
Frequency converter performance and use
5
Gotta
Avatar
9/26/2021 7:10 PM
Hi, I have a site in Australia. We build air conditioning units for other countries and want to test the units. Looking for a converter that can convert 240v 50Hz to 120v 60Hz but also gave a variant on the 120v side, so the voltage can be varied. Is this something you could assist with?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can.
Our converter output voltage and frequency can be adjusted in the range (0-150V) & (40-120Hz).
What is the tested air conditioning unit rated current (Amps), and power capacity? Also, what is its expected increase in current at the starting period?
Clarification: When the motor starts to spin up, it pulls high inrush current that may reach 6 times its rated value and lasts from few milliseconds to 1-3 seconds unless the motor is attached to starting controller like soft starter or VFD.
Which frequency converter would you recommend to us?
5
Fredrik
Avatar
10/11/2021 8:16 PM
We build boats and ship them to Europe regularly and they need to test the systems on the boats. We need to go from 120V 60Hz to 240V 50Hz. Currently they are using a generator to obtain the 50Hz, but it has been unreliable at best. They estimate the range to be between 30-50 Amps, possibly less. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your specs, recommended frequency converter model: HZ-50-1120, 20kVA power capacity, input: 1ph, 120V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable ( 0-300V), adjustable (40-120Hz), 83.2A.
I need a frequency converter. Do you have any recommendations?
5
Denali
Avatar
10/20/2021 8:11 PM
I need a frequency converter with:
Input: 400V, 50hz, three phase.
Output: 220V/110V 60Hz. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, recommended frequency converter model: HZ-50-3320, 20kVA power capacity, input: 3ph, Wye (L1, L2, L3 + N, G), 400V (+/- 10%), 50/60Hz and output: 3ph, Wye/Delta (L1, L2, L3 + N, G), adjustable (0-260V), adjustable (40-120Hz), 55.6A.
We need the following frequency converter specs
5
Lhaas
Avatar
1/11/2022 6:17 PM
We need the following converter specs: frequency converter, 400V/3phase/50Hz to 230v/3phase/60Hz and the capacity must be 40 kW and 100 Amps. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your specs, recommended frequency converter model: HZ-50-3360, 60kVA power capacity, input: 3ph, Wye (L1, L2, L3 + N, G), 400V (+/- 10%), 50/60Hz and output: 3ph, Wye/Delta (L1, L2, L3 + N, G), adjustable (0-260V), adjustable (40-120Hz), 166.4A.
Can you reproduce the documentation for this frequency converter?
5
berg
Avatar
6/13/2023 2:04 AM
I hope you have been well. I am reaching out because we are starting to use the equipment from this order in short order after some unforeseen delays.
Unfortunately, during the delay the manuals/documents and CE declaration of conformity seem to have been misplaced.
Is there any way you could reproduce the documentation for this unit for us? I would really appreciate it.
Thank you very much.
Was this review helpful? Yes No (0/0)
ATO Responded
Please check the attached user manual and factory test report.
You can refer to our demo video, please see on: https://www.youtube.com/watch?v=xRDzC1vHtIw
High efficiency converter
5
Phillip
Avatar
5/7/2024 3:17 AM
The company recently purchased a number of converters, management took this purchase quite seriously and asked a couple questions. The first was whether there were any lower voltage range converters available? For example: One rated 0-150V per phase instead of 0-300V. Also, would this converter be able to help couple the converter with a power conditioner, or use a harmonic filter after the converter?
Was this review helpful? Yes No (0/0)
ATO Responded
1.Is the rated 0-150V per phase you mentioned phase voltage or line voltage? Our converter's low-end voltage 0-150V is the phase voltage, and the corresponding line voltage range is 0-260VAC. It can be understood as you want the line voltage 0-260V?
2.Regarding the problem of harmonic interference, the vibration problem of the motor can Not be solved by adding a filter to the output end of the converter. Because we have tested similar loads, this is related to the motor speed and can Not be solved by simply adding a filter. We are still looking for ways to solve the vibration problem of this motor at low voltage and high speed.
Thanks for the question.
Only registered users can write reviews