100kVA 3-Phase 380v 50Hz/460v 60Hz Frequency Converter

$27,492.67
Reliable 100 kVA solid state (static) frequency converter, built-in step-up/step-down transformer, convert three phase 380V (e.g. Finland) to 460V (e.g. Brazil), change 50Hz to 60Hz, 400Hz and pure sine wave output for US and Europe appliances.
SKU: HZ-50-33100
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

100 kVA frequency converter for converting 50 Hz to 60 Hz, 400 Hz, 3 phase input, single phase or three phase output, compatible with 3 phase 208V, 220V, 380V, 415V, 480V power system.

Specification:

ModelHZ-50-33100
Capacity100 kVA
Dimension1500*860*1430 mm
Weight760 kg
InputVoltage3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V ±10% (option *)
3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% (option *)
3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10% (option *)
Frequency50 Hz, 60 Hz
OutputVoltage, current110V Setting (Low grade): 0-150V (phase voltage), 0-260V (line voltage) 277.6A
220V Setting (High grade): 0-300V (phase voltage), 0-520V (line voltage) 138.8A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
-When the output is 400Hz, the load capacity can only reach 50% of the rated capacity.
-When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
-You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months

How to Test a 9V Transformer Power Supply in a Frequency Converter?

This video shows you how to use a multimeter to test the IGBT in a frequency converter.

How to Use a Multimeter to Test the IGBT in a Frequency Converter?

This video shows you how to use a multimeter to test the IGBT in a frequency converter.

How to Check the Fuse of a Frequency Converter?

In this video, the steps on how to check the fuse of a frequency converter using a multimeter are shown.

Product reviews
Frequency converter recommended by ATO
5
Bindner
Avatar
7/28/2021 8:40 PM
We want to convert 1-phase, 230V, 50Hz "UK supply" to 1-phase, one hot line (L   N,G), 230V, 60Hz to feed AC/DC PSU modules with 12.6V output delivering 6 amps, what do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, and if your equipment is around 100-200W, then recommended frequency converter model: HZ-60-1101, 1kVA power capacity, input: 1ph, 230V (+/- 10%), 50/60Hz and output: 1ph (L ,N,G), adjustable (0-300V), adjustable (40-120Hz), 4.2A.
ATO recommends the model to me according to my needs
5
Sherri
Avatar
8/22/2021 9:39 PM
We need 100kVA converter 380Vac 50HZ (L1,L2,L3, N,G) to 440Vac 60Hz (L1,L2,L3, N,G), we have a 65kW (with VFD), in this case the inrush current is low. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, based on your choice, recommended frequency converter model: HZ-50-33100, 100kVA power capacity, input: 3ph, Wye (L1,L2,L3 + N,G), 380V (+/- 10%), 50/ 60Hz and output: 3ph, Wye/Delta (L1,L2,L3 + N,G), adjustable (0-520V), adjustable (40-120Hz), 138.8A.
Our new requirements for frequency converter
5
Wigginton
Avatar
9/22/2021 7:28 PM
Revising my request, the minimum frequency of 40 Hz can be modified to 48 Hz
Considering the performances is the converter equipped with output LOW PASS filter? If yes, could you please deliver a harmonic frequency spectrum of the output waveform?
The converter output transformer 3 phase is wye connected. could the converter be connected for single phase output switching by a selector the electronics firing control and manually modify the transformer connections?
The control of frequency and output voltage can be remotely managed by SW control or HW control (potentiometer for example)?
Please send an update formal offer for two versions 15 and 30 KVA with the same performances 48-120 Hz output 0-520 V to the following address.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for your prompt reply. According to your new requirements below, we need you to confirm again and then we will better quote.
1. We can add a LOW PASS filter to the output end of the converter, but for now we don't have measuring instrument, we cannot provide the output waveform to you.
2. Yes, the converter output transformer 3 phase is way connected. Our converter can customize the selector to modify the transformer connection manually.
3. We can remotely manage the frequency (only 2 digits) and output voltage control through software control or hardware control(such as potentiometer). At present, the remote control of our frequency can only reach 2 digits, which means that the output frequency of 48-99 Hz can be controlled remotely, and the frequency above 3 digits 100 Hz is not supported for now. Is that acceptable to you? Or what is the frequency range that you actually use?
Please kindly confirm the above three points, and then we will offer you a formal quotation.
I am looking for a frequency converter
5
Janice
Avatar
9/27/2021 7:08 PM
Hi, I am looking for a step-down transformer/ frequency converter. To go from 240v 50Hz to 120v 60Hz. Honestly, it is for some music equipment, a 5 watt amp, a 15 watt amp and a series of guitar pedals. The total power draw is quite low. In total, it is probably less than 50 watts peak.
These products look like they do exactly what I'd want, but is there anything available that matches my needs?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our frequency converter will convert 240V, 50Hz (supply) to 120V, 60Hz (load) perfectly.
In your case, recommend the converter model: HZ-60-500W.
We have these needs for frequency converter
5
Catma
Avatar
10/12/2021 7:37 PM
We would need product information for a frequency converter with these requirements:
Input: 440V – 60Hz – 3 phases   GND
Output: 230V – 50Hz – 1 phase   Neutral   GND
Peak Amp in output: 55A
Max continuous Amp in output: 13A
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, based on your specs, recommended frequency converter model: HZ-50-3115, 15kVA power capacity, input: 3ph, Delta (L1, L2, L3 + G), 440V (+/- 10%), 50/60Hz and output: 1ph, (L + N, G), adjustable (0-300V), adjustable (40-120Hz), 62.5A.
Which frequency converter do you recommend for us to use?
5
Albert
Avatar
12/8/2021 6:58 PM
We need a converter for complete machine supply for press brake. Our press brake total connected load 20kVA.
Input voltage is 400v 3 Phase and the required frequency is 50Hz. The full load current is 29A.
So we need the frequency converter to convert from 60Hz to 50Hz with the same 400V.
The system asks the machine to have hydraulic pumps and servo motors. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
If your Press Brake has only servo motors with connected drives, then it will Not be expected to see high inrush current of such motors, and in this case, recommended frequency converter model: HZ-50-3345, 45kVA power capacity, input: 3ph, Wye (L1,L2,L3 + N,G), 400V (+/- 10%), 50/60Hz and output: 3ph, Wye/Delta (L1,L2,L3 + N,G), adjustable (0-520V ), adjustable (40-120Hz), 62.5A.
Does the terminal of the frequency converter have a neutral wire?
5
Trabucco
Avatar
1/12/2022 6:17 PM
Your frequency converter input terminal or output terminals having neutral line?
Was this review helpful? Yes No (0/0)
ATO Responded
For converter input "your supply" configuration, it can be 3-phase, Wye (L1, L2, L3 + N, G) or 3-phase, Delta (L1, L2, L3 + G ). Which one do you need?
If the neutral is required "Wye", your supply must have this terminal.
If your supply is 3 phase 4 wire (3 wire for hot conductor, and the fourth one is for neutral), then you have to use 3-phase, Wye (L1, L2, L3 + N, G) converter config.
The converter output will be (L1, L2, L3 + N, G), and it works for both Delta and Wye configuration. We mean neutral can be used or not. It's up to you.
We currently own one of your frequency converters.
5
Lizard
Avatar
5/26/2022 3:26 AM
Frequency Converter Model HZ-50-33100, 100KVA.
We are looking at getting this unit serviced and checked. We are based in the UK (London) and was wondering if you had agents here that would be able to service it please.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, we don't have an agent repair service elsewhere, and we can only provide technical support via email currently. But please don’t worry, as the problem will be solved. Just keep answering our inquires accurately.
1. Please describe the fault of this converter to us in detail.
2. Now, open converter side covers and power on the converter, then take a video showing us the internal main circuit boards, especially the ones with red led indicators and beeping sound, and show us the converter display as well while the converter is running ..
3. Measure the converter output voltage at no load, applied on its terminals via external multi-meter >>> U, N -SN, -WN, and feedback measurements to us.
4. If the converter has an alarm sound and the output voltage is abnormal, please measure the fuse, IGBT module, and driver board according to the attached troubleshooting document, and feedback the measurement results to us.
Trouble in converter
5
Leo
Avatar
10/19/2023 9:39 PM
We currently own a GoHz Frequency converter model HZ-50-3310.
We are having an issue with unit not being able to obtain an output of 200V@400Hz while under load of 200A.
It recently worked just fine but does not seem to meet requirements now.
We need from 195V to 210V @400Hz for our testing requirements.

We have tried 2 known good units that we typically test with exact similar results.
One output leg (U) is good but the other 2 output legs (V&W) readings are reading 8-10 volts lower than leg “U”.
We cannot maintain the 200V required for the test.

I would also like a quote for a 2nd unit with the same specs.

I need to get the present unit up & running ASAP.

Is there any way to expedite a repair/troubleshooting here on site of our present unit and expediting of a new unit we are interested in purchasing.

Please advise your repair/troubleshoot and quickest purchase and ship on a new unit.
Was this review helpful? Yes No (0/0)
ATO Responded
1. First of all, the maximum output current of this 10KVA converter is only 27A. So the ""200V@400Hz while under load of 200A."" you mentioned below is the wrong number. It should be 20A, right?

2. Now, please remove the load connection, then run the converter with no load, use a multimeter to measure the phase voltages (U-N, V-N, W-N) of the output terminals and feedback the measurement results to us.

3. After completing step 2, you can measure the feedback capacitance of V-phase and W-phase according to the attached troubleshooting document and feedback the measurement results to us.
Technical support
5
Karl
Avatar
5/8/2024 3:56 AM
I purchased the 3-phase frequency converter last year. When turned on, a beeping is heard. I suspect 1 phase may be damaged or needs to be reset. Can you provide any technical support?
Was this review helpful? Yes No (0/0)
ATO Responded
At first, please do not worry, as the problem will be solved. Just keep answering our inquires accurately.
1. Now, open converter side covers and power on the converter, then take a video showing us the internal main circuit boards, especially the ones with red LED indicators and beeping sound, and show us the converter display as well while the converter is running. You can send us the large video file via wetransfer.com.
2. Measure the converter output voltage at no load, applied on its terminals via external multi-meter, and feedback measurements to us.
3. Please send a picture of the nameplate label of our converter and the specific specifications of the connected load (such as total load power, rated voltage and maximum current) to our email address support@ato.com.
Good Frequency Converter
5
Papma
Avatar
5/8/2024 4:03 AM
After a period of time, I think it is still very good, here I would like to share some operations that are useful in the process of using it. First, measuring the input terminals-all phases are present at approx. 120V @ 60Hz. Measuring the Output terminals-2 phases reads approx. 120V /400Hz. The third output terminal (with blue circle) reads 0 volts, and beeping at approx. 1x/ second. Then, the BC-4800 unit that caused the unit failure was operating at approx. 4kW, 60Hz , 3 phase, and unit had an internal short, which shorted one phase. The BC-4800 had a 50A/ 3 phase circuit breaker that tripped upon failure. The unit which was going into test (BC-15k), will requires 120V, 3 phase, 400Hz. Power Source loading on that model will be approximately 25kW when at max BC-15k overload condition.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for the update. The fuse and IGBT module seem to be normal, the driver board and contactor seem to be abnormal, but we still want to confirm when you measure the AC voltage and DC voltage of the driver board, is the converter powered on? Have you pressed the green start button to run the converter? Please confirm. Because when measuring the driver board, you must press the green start button switch to start the machine. The same goes for the contactor, you have to press the green push button switch to start operation, and then you can operate the knife switch (0-150V/ 0-300V) next to the output circuit breaker. You need to toggle the switch back and forth and then check if the contactor is closing properly.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

100 kVA frequency converter for converting 50 Hz to 60 Hz, 400 Hz, 3 phase input, single phase or three phase output, compatible with 3 phase 208V, 220V, 380V, 415V, 480V power system.

Specification:

ModelHZ-50-33100
Capacity100 kVA
Dimension1500*860*1430 mm
Weight760 kg
InputVoltage3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V ±10% (option *)
3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% (option *)
3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10% (option *)
Frequency50 Hz, 60 Hz
OutputVoltage, current110V Setting (Low grade): 0-150V (phase voltage), 0-260V (line voltage) 277.6A
220V Setting (High grade): 0-300V (phase voltage), 0-520V (line voltage) 138.8A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
-When the output is 400Hz, the load capacity can only reach 50% of the rated capacity.
-When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
-You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months

Product reviews
Frequency converter recommended by ATO
5
Bindner
Avatar
7/28/2021 8:40 PM
We want to convert 1-phase, 230V, 50Hz "UK supply" to 1-phase, one hot line (L   N,G), 230V, 60Hz to feed AC/DC PSU modules with 12.6V output delivering 6 amps, what do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, and if your equipment is around 100-200W, then recommended frequency converter model: HZ-60-1101, 1kVA power capacity, input: 1ph, 230V (+/- 10%), 50/60Hz and output: 1ph (L ,N,G), adjustable (0-300V), adjustable (40-120Hz), 4.2A.
ATO recommends the model to me according to my needs
5
Sherri
Avatar
8/22/2021 9:39 PM
We need 100kVA converter 380Vac 50HZ (L1,L2,L3, N,G) to 440Vac 60Hz (L1,L2,L3, N,G), we have a 65kW (with VFD), in this case the inrush current is low. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, based on your choice, recommended frequency converter model: HZ-50-33100, 100kVA power capacity, input: 3ph, Wye (L1,L2,L3 + N,G), 380V (+/- 10%), 50/ 60Hz and output: 3ph, Wye/Delta (L1,L2,L3 + N,G), adjustable (0-520V), adjustable (40-120Hz), 138.8A.
Our new requirements for frequency converter
5
Wigginton
Avatar
9/22/2021 7:28 PM
Revising my request, the minimum frequency of 40 Hz can be modified to 48 Hz
Considering the performances is the converter equipped with output LOW PASS filter? If yes, could you please deliver a harmonic frequency spectrum of the output waveform?
The converter output transformer 3 phase is wye connected. could the converter be connected for single phase output switching by a selector the electronics firing control and manually modify the transformer connections?
The control of frequency and output voltage can be remotely managed by SW control or HW control (potentiometer for example)?
Please send an update formal offer for two versions 15 and 30 KVA with the same performances 48-120 Hz output 0-520 V to the following address.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for your prompt reply. According to your new requirements below, we need you to confirm again and then we will better quote.
1. We can add a LOW PASS filter to the output end of the converter, but for now we don't have measuring instrument, we cannot provide the output waveform to you.
2. Yes, the converter output transformer 3 phase is way connected. Our converter can customize the selector to modify the transformer connection manually.
3. We can remotely manage the frequency (only 2 digits) and output voltage control through software control or hardware control(such as potentiometer). At present, the remote control of our frequency can only reach 2 digits, which means that the output frequency of 48-99 Hz can be controlled remotely, and the frequency above 3 digits 100 Hz is not supported for now. Is that acceptable to you? Or what is the frequency range that you actually use?
Please kindly confirm the above three points, and then we will offer you a formal quotation.
I am looking for a frequency converter
5
Janice
Avatar
9/27/2021 7:08 PM
Hi, I am looking for a step-down transformer/ frequency converter. To go from 240v 50Hz to 120v 60Hz. Honestly, it is for some music equipment, a 5 watt amp, a 15 watt amp and a series of guitar pedals. The total power draw is quite low. In total, it is probably less than 50 watts peak.
These products look like they do exactly what I'd want, but is there anything available that matches my needs?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our frequency converter will convert 240V, 50Hz (supply) to 120V, 60Hz (load) perfectly.
In your case, recommend the converter model: HZ-60-500W.
We have these needs for frequency converter
5
Catma
Avatar
10/12/2021 7:37 PM
We would need product information for a frequency converter with these requirements:
Input: 440V – 60Hz – 3 phases   GND
Output: 230V – 50Hz – 1 phase   Neutral   GND
Peak Amp in output: 55A
Max continuous Amp in output: 13A
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, based on your specs, recommended frequency converter model: HZ-50-3115, 15kVA power capacity, input: 3ph, Delta (L1, L2, L3 + G), 440V (+/- 10%), 50/60Hz and output: 1ph, (L + N, G), adjustable (0-300V), adjustable (40-120Hz), 62.5A.
Which frequency converter do you recommend for us to use?
5
Albert
Avatar
12/8/2021 6:58 PM
We need a converter for complete machine supply for press brake. Our press brake total connected load 20kVA.
Input voltage is 400v 3 Phase and the required frequency is 50Hz. The full load current is 29A.
So we need the frequency converter to convert from 60Hz to 50Hz with the same 400V.
The system asks the machine to have hydraulic pumps and servo motors. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
If your Press Brake has only servo motors with connected drives, then it will Not be expected to see high inrush current of such motors, and in this case, recommended frequency converter model: HZ-50-3345, 45kVA power capacity, input: 3ph, Wye (L1,L2,L3 + N,G), 400V (+/- 10%), 50/60Hz and output: 3ph, Wye/Delta (L1,L2,L3 + N,G), adjustable (0-520V ), adjustable (40-120Hz), 62.5A.
Does the terminal of the frequency converter have a neutral wire?
5
Trabucco
Avatar
1/12/2022 6:17 PM
Your frequency converter input terminal or output terminals having neutral line?
Was this review helpful? Yes No (0/0)
ATO Responded
For converter input "your supply" configuration, it can be 3-phase, Wye (L1, L2, L3 + N, G) or 3-phase, Delta (L1, L2, L3 + G ). Which one do you need?
If the neutral is required "Wye", your supply must have this terminal.
If your supply is 3 phase 4 wire (3 wire for hot conductor, and the fourth one is for neutral), then you have to use 3-phase, Wye (L1, L2, L3 + N, G) converter config.
The converter output will be (L1, L2, L3 + N, G), and it works for both Delta and Wye configuration. We mean neutral can be used or not. It's up to you.
We currently own one of your frequency converters.
5
Lizard
Avatar
5/26/2022 3:26 AM
Frequency Converter Model HZ-50-33100, 100KVA.
We are looking at getting this unit serviced and checked. We are based in the UK (London) and was wondering if you had agents here that would be able to service it please.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, we don't have an agent repair service elsewhere, and we can only provide technical support via email currently. But please don’t worry, as the problem will be solved. Just keep answering our inquires accurately.
1. Please describe the fault of this converter to us in detail.
2. Now, open converter side covers and power on the converter, then take a video showing us the internal main circuit boards, especially the ones with red led indicators and beeping sound, and show us the converter display as well while the converter is running ..
3. Measure the converter output voltage at no load, applied on its terminals via external multi-meter >>> U, N -SN, -WN, and feedback measurements to us.
4. If the converter has an alarm sound and the output voltage is abnormal, please measure the fuse, IGBT module, and driver board according to the attached troubleshooting document, and feedback the measurement results to us.
Trouble in converter
5
Leo
Avatar
10/19/2023 9:39 PM
We currently own a GoHz Frequency converter model HZ-50-3310.
We are having an issue with unit not being able to obtain an output of 200V@400Hz while under load of 200A.
It recently worked just fine but does not seem to meet requirements now.
We need from 195V to 210V @400Hz for our testing requirements.

We have tried 2 known good units that we typically test with exact similar results.
One output leg (U) is good but the other 2 output legs (V&W) readings are reading 8-10 volts lower than leg “U”.
We cannot maintain the 200V required for the test.

I would also like a quote for a 2nd unit with the same specs.

I need to get the present unit up & running ASAP.

Is there any way to expedite a repair/troubleshooting here on site of our present unit and expediting of a new unit we are interested in purchasing.

Please advise your repair/troubleshoot and quickest purchase and ship on a new unit.
Was this review helpful? Yes No (0/0)
ATO Responded
1. First of all, the maximum output current of this 10KVA converter is only 27A. So the ""200V@400Hz while under load of 200A."" you mentioned below is the wrong number. It should be 20A, right?

2. Now, please remove the load connection, then run the converter with no load, use a multimeter to measure the phase voltages (U-N, V-N, W-N) of the output terminals and feedback the measurement results to us.

3. After completing step 2, you can measure the feedback capacitance of V-phase and W-phase according to the attached troubleshooting document and feedback the measurement results to us.
Technical support
5
Karl
Avatar
5/8/2024 3:56 AM
I purchased the 3-phase frequency converter last year. When turned on, a beeping is heard. I suspect 1 phase may be damaged or needs to be reset. Can you provide any technical support?
Was this review helpful? Yes No (0/0)
ATO Responded
At first, please do not worry, as the problem will be solved. Just keep answering our inquires accurately.
1. Now, open converter side covers and power on the converter, then take a video showing us the internal main circuit boards, especially the ones with red LED indicators and beeping sound, and show us the converter display as well while the converter is running. You can send us the large video file via wetransfer.com.
2. Measure the converter output voltage at no load, applied on its terminals via external multi-meter, and feedback measurements to us.
3. Please send a picture of the nameplate label of our converter and the specific specifications of the connected load (such as total load power, rated voltage and maximum current) to our email address support@ato.com.
Good Frequency Converter
5
Papma
Avatar
5/8/2024 4:03 AM
After a period of time, I think it is still very good, here I would like to share some operations that are useful in the process of using it. First, measuring the input terminals-all phases are present at approx. 120V @ 60Hz. Measuring the Output terminals-2 phases reads approx. 120V /400Hz. The third output terminal (with blue circle) reads 0 volts, and beeping at approx. 1x/ second. Then, the BC-4800 unit that caused the unit failure was operating at approx. 4kW, 60Hz , 3 phase, and unit had an internal short, which shorted one phase. The BC-4800 had a 50A/ 3 phase circuit breaker that tripped upon failure. The unit which was going into test (BC-15k), will requires 120V, 3 phase, 400Hz. Power Source loading on that model will be approximately 25kW when at max BC-15k overload condition.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for the update. The fuse and IGBT module seem to be normal, the driver board and contactor seem to be abnormal, but we still want to confirm when you measure the AC voltage and DC voltage of the driver board, is the converter powered on? Have you pressed the green start button to run the converter? Please confirm. Because when measuring the driver board, you must press the green start button switch to start the machine. The same goes for the contactor, you have to press the green push button switch to start operation, and then you can operate the knife switch (0-150V/ 0-300V) next to the output circuit breaker. You need to toggle the switch back and forth and then check if the contactor is closing properly.
Only registered users can write reviews
Customers who bought this item also bought

60kVA 3-Phase 220v 60Hz/380v 50Hz Frequency Converter

HZ-50-3360
$17,904.31
60 kVA three phase 220V to 400V frequency converter, also change 415V 380V to 208V 240V in one step, output 50Hz / 60Hz up to 400Hz adjustable, provide both voltage and frequency conversion in the same unit.