30A High Voltage DC Contactor, 12V/24V coil

$87.23
Cheap Price DC contactor relay, normally open (SPST-NO) type, 30 amps rated load current of contact circuit, available with 12V or 24V coils. Magnetic contactor is widely used in the DC 12-900V high voltage field, offers exceptional performance in an extremely small and lightweight device.
SKU: ATO-DCCON-HV30
*
Free Shipping
Delivery date: 6-12 days

Features

  • 30A DC contactor adopts high-strength epoxy resin sealing with nitrogen-based gas filling, eliminating arc leakage risks, preventing contact oxidation, and ensuring safe operation without fire or explosion during its service life.
  • It provides reliable performance with 30A continuous current at 85℃, IP67 contact protection, insulation resistance up to 100MΩ (1000V DC), and dielectric strength of 2.2kV between contacts and coil.
  • High voltage DC contactor meets IEC 60664-1, GB/T14048.1, GB/T14048.4 standards, complies with RoHS (2015/863/EU) and REACH (1907/2006/EC), and is certified by CE, CCC, and RoHS.

Specifications

ModelATO-ADH-30
Main Contact Specification
Contact Arrangement1K (1NO)
Contact PolarityNon-polarity
Contact Resistance≤0.5mΩ (at 200A)
Max. Switching Voltage1,000V DC
Max. Breaking Current250A (320V DC) 1 Ops
Electrical Endurance (Resistive Load)10,000 Ops (1,500V DC, 30A)
6,000 Ops (1,000V DC, 50A)
20,000 Ops (750V DC, 30A)
25,000 Ops (450V DC, 30A)
Mechanical Endurance300,000 Ops
Withstand Current30A, Continuous
45A, 60min
60A, 20min
120A, 30s
Performance Parameter (at 23℃)
Pickup VoltageSee Coil Parameter Tables
Dropout VoltageSee Coil Parameter Tables
Pickup Time≤30ms
Contact Bounce Period≤5ms
Dropout Time≤10ms
Dielectric StrengthBetween Main Contacts10,000V DC 10s
Between Main Contact and Coil3,500V DC 1min
Insulation ResistanceInitial State1,000MΩ
After Electrical Life50MΩ 1min
ShockStability20g (Power On)
Strength50g
Vibration10g, 10~500Hz, 1/2 Sine Wave (Power On)
Relative Humidity5%~95%RH
Temperature-40℃~85℃
Load TerminalM4 Internal Thread
WeightAbout 115g
Dimension51.7x36x46mm
Auxiliary Contact Parameter
Aux. Contact Arrangement/
Aux. Contact Rated Current/
Aux. Contact Max. Breaking Voltage/


Coil Parameter

Coil VoltagePickup Voltage (VDC)Dropout Voltage (VDC)Coil ResistanceCoil Power Consumption
12V≤70%Us5-40%Us≤0.33A≤5W
24V≤70%Us5-40%Us≤0.17A≤5W
36V≤70%Us5-40%Us≤0.12A≤5W
48V≤70%Us5-40%Us≤0.09A≤5W
60V≤70%Us5-40%Us≤0.07A≤5W
72V≤70%Us5-40%Us≤0.06A≤5W


Dimension (Unit: mm)

30A high voltage DC contactor dimension

Wiring Diagram

30A high voltage dc contactor wiring diagram

Tips: Reasons for the contacts of contactor being unable to close after powering on

  1. Power supply circuit of the coil shorts.
  2. Coil circuit breaks.
  3. Coil's control voltage is too low.
  4. The contactor's coil has burnt out, thermal deformation of coil skeleton makes the iron core
  5. unable to be sucked to a proper place, thus the contact can't close.
  6. Adhesion of main contact.
  7. A foreign body or hard spots in the armature.
  8. Main contact dislocates (mainly for large contactor, bridge type contact).
  9. Auxiliary contact is not well installed.
Product reviews
Provide 30A high voltage DC contactor with 12V/24V coil
5
Sarah
Avatar
2/25/2021 8:18 PM
I found a suitable factory-use in the ATO.com online store. 24V coils is what I need, and the coil connection method is also very convenient. We use it in the DC high voltage field to provide excellent performance in a lightweight device.
Was this review helpful? Yes No (0/0)
Questions about 30A high voltage DC contactor
5
Sandie
Avatar
11/7/2021 11:02 PM
Is your 30A high voltage DC contactor driven with DC or PWM? Are both coils driven from 1 input, or are the 2 inputs separate?
Was this review helpful? Yes No (0/0)
ATO Responded
Our DC contactor is DC driven, and 1 coil controls 1NO contact.
Could DC contactor handle 120V AC?
5
janaya
Avatar
7/24/2023 8:26 PM
I am looking at the 30A High Voltage DC contactor, 12V/24V coil.
I would like to know if this device can handle AC loads.
I see that the device is rated for 12-900V DC. Could it handle 120V AC?
All amps will be well below 30A.
Was this review helpful? Yes No (0/0)
ATO Responded
Our 30A High Voltage DC contactor can withstand 120V AC.
The coil voltage can be selected from 12/24V.
Will the contactor work well with a load of 12-900V DC?
5
reut
Avatar
7/24/2023 9:28 PM
Thank you for your response.
Can you clarify further, please?
Will the device work well with a load of 12-900V DC, and will it work for AC loads as well? Is there a range on what voltage load I can use with AC?
For example, would it work with a 220V AC load as well as a 120V AC load? Additionally, the main contact has female M5 threading.
Does the bolt come with the product, or would one need to buy one separately?
Was this review helpful? Yes No (0/0)
ATO Responded
The device can work normally with a load of 12-900V DC, the rated load voltage range is 12-900V DC, it cannot work with 220V AC load and 120V AC load.
The main contacts do not have female M5 threads, and the fixing bolts need to be purchased additionally.
The control end needs to use a DC power supply, and the load end can use an AC load, and the device can work under 120V AC and 220VAC loads.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Features

  • 30A DC contactor adopts high-strength epoxy resin sealing with nitrogen-based gas filling, eliminating arc leakage risks, preventing contact oxidation, and ensuring safe operation without fire or explosion during its service life.
  • It provides reliable performance with 30A continuous current at 85℃, IP67 contact protection, insulation resistance up to 100MΩ (1000V DC), and dielectric strength of 2.2kV between contacts and coil.
  • High voltage DC contactor meets IEC 60664-1, GB/T14048.1, GB/T14048.4 standards, complies with RoHS (2015/863/EU) and REACH (1907/2006/EC), and is certified by CE, CCC, and RoHS.

Specifications

ModelATO-ADH-30
Main Contact Specification
Contact Arrangement1K (1NO)
Contact PolarityNon-polarity
Contact Resistance≤0.5mΩ (at 200A)
Max. Switching Voltage1,000V DC
Max. Breaking Current250A (320V DC) 1 Ops
Electrical Endurance (Resistive Load)10,000 Ops (1,500V DC, 30A)
6,000 Ops (1,000V DC, 50A)
20,000 Ops (750V DC, 30A)
25,000 Ops (450V DC, 30A)
Mechanical Endurance300,000 Ops
Withstand Current30A, Continuous
45A, 60min
60A, 20min
120A, 30s
Performance Parameter (at 23℃)
Pickup VoltageSee Coil Parameter Tables
Dropout VoltageSee Coil Parameter Tables
Pickup Time≤30ms
Contact Bounce Period≤5ms
Dropout Time≤10ms
Dielectric StrengthBetween Main Contacts10,000V DC 10s
Between Main Contact and Coil3,500V DC 1min
Insulation ResistanceInitial State1,000MΩ
After Electrical Life50MΩ 1min
ShockStability20g (Power On)
Strength50g
Vibration10g, 10~500Hz, 1/2 Sine Wave (Power On)
Relative Humidity5%~95%RH
Temperature-40℃~85℃
Load TerminalM4 Internal Thread
WeightAbout 115g
Dimension51.7x36x46mm
Auxiliary Contact Parameter
Aux. Contact Arrangement/
Aux. Contact Rated Current/
Aux. Contact Max. Breaking Voltage/


Coil Parameter

Coil VoltagePickup Voltage (VDC)Dropout Voltage (VDC)Coil ResistanceCoil Power Consumption
12V≤70%Us5-40%Us≤0.33A≤5W
24V≤70%Us5-40%Us≤0.17A≤5W
36V≤70%Us5-40%Us≤0.12A≤5W
48V≤70%Us5-40%Us≤0.09A≤5W
60V≤70%Us5-40%Us≤0.07A≤5W
72V≤70%Us5-40%Us≤0.06A≤5W


Dimension (Unit: mm)

30A high voltage DC contactor dimension

Wiring Diagram

30A high voltage dc contactor wiring diagram

Tips: Reasons for the contacts of contactor being unable to close after powering on

  1. Power supply circuit of the coil shorts.
  2. Coil circuit breaks.
  3. Coil's control voltage is too low.
  4. The contactor's coil has burnt out, thermal deformation of coil skeleton makes the iron core
  5. unable to be sucked to a proper place, thus the contact can't close.
  6. Adhesion of main contact.
  7. A foreign body or hard spots in the armature.
  8. Main contact dislocates (mainly for large contactor, bridge type contact).
  9. Auxiliary contact is not well installed.
Product reviews
Provide 30A high voltage DC contactor with 12V/24V coil
5
Sarah
Avatar
2/25/2021 8:18 PM
I found a suitable factory-use in the ATO.com online store. 24V coils is what I need, and the coil connection method is also very convenient. We use it in the DC high voltage field to provide excellent performance in a lightweight device.
Was this review helpful? Yes No (0/0)
Questions about 30A high voltage DC contactor
5
Sandie
Avatar
11/7/2021 11:02 PM
Is your 30A high voltage DC contactor driven with DC or PWM? Are both coils driven from 1 input, or are the 2 inputs separate?
Was this review helpful? Yes No (0/0)
ATO Responded
Our DC contactor is DC driven, and 1 coil controls 1NO contact.
Could DC contactor handle 120V AC?
5
janaya
Avatar
7/24/2023 8:26 PM
I am looking at the 30A High Voltage DC contactor, 12V/24V coil.
I would like to know if this device can handle AC loads.
I see that the device is rated for 12-900V DC. Could it handle 120V AC?
All amps will be well below 30A.
Was this review helpful? Yes No (0/0)
ATO Responded
Our 30A High Voltage DC contactor can withstand 120V AC.
The coil voltage can be selected from 12/24V.
Will the contactor work well with a load of 12-900V DC?
5
reut
Avatar
7/24/2023 9:28 PM
Thank you for your response.
Can you clarify further, please?
Will the device work well with a load of 12-900V DC, and will it work for AC loads as well? Is there a range on what voltage load I can use with AC?
For example, would it work with a 220V AC load as well as a 120V AC load? Additionally, the main contact has female M5 threading.
Does the bolt come with the product, or would one need to buy one separately?
Was this review helpful? Yes No (0/0)
ATO Responded
The device can work normally with a load of 12-900V DC, the rated load voltage range is 12-900V DC, it cannot work with 220V AC load and 120V AC load.
The main contacts do not have female M5 threads, and the fixing bolts need to be purchased additionally.
The control end needs to use a DC power supply, and the load end can use an AC load, and the device can work under 120V AC and 220VAC loads.
Only registered users can write reviews
Customers who bought this item also bought

RTD Sensor with transmitter, Pt100, 2 Wire

ATO-RTD-T2W
$112.31
RTD sensor built-in small transmitter. It converts temperature to 4-20mA standard signal proportional to the electrical signals of thermistor, and outputs to display instrument or DCS system in control room. Transmitter adopts silicone rubber seal structure, good anti-interference ability, shock and humidity, apply to harsh environments. Measuring temperature range -200~+420 ℃.

Voltage Monitoring Relay, Under/Over Voltage, 1 Phase, 110-240V AC/DC

ATO-MR-SVR1000
$115.67
Single phase voltage monitoring relay, suitable for undervoltage and overvoltage monitoring of DC 12V, AC/DC 24-48V or AC/DC 110V-240V, adjustable delay time, compact size relay with 1 CO & 1 NC contacts, real-time LCD for voltage, operation and fault status display, DIN rail mounting, high quality and low cost.

IP66 Aluminum Waterproof Junction Box

ATO-WJB-67
$52.46
The series of waterproof junction box is made of aluminum alloy die-casting, waterproof rating is IP66. Adopting silicone sealing strip, good sealing performance, waterproof, dustproof, corrosion-resistant, anti-radio frequency interference, easy to process. Aluminum waterproof junction box is very suitable as electrical junction box for indoor and outdoor electrical engineering.