50A DC Contactor, 12V/24V/48V

$102.61
High quality DC contactor with 12V, 24V, 36V and 48V coil voltage for choice, normally open or normally closed type, contact circuit rated load current of 50A, offers exceptional performance in an extremely small and lightweight device.
SKU: ATO-DCCON-C50
*
*
Availability: In stock
Free Shipping
Delivery date: 2-12 days

50A DC contactor with normally open and normally closed main contact, designed for direct current loads, particularly for electric vehicles, telecommunication equipment, car batteries, trains, ships, and electronic control systems.

Features

  • The DC contactor has the characteristics of small size, large load capacity, long service life and simple maintenance, and is very popular among users.
  • 50 amps contactor complies with the requirements of the ministry standards JB2286-78, JB3974-85, YD/585-92, YD/T512-92. It has been tested in the factory and by relevant testing units and meets the requirements of the ministry standards. It has been used by users for many years to satisfy users to the maximum extent. Needed, reliable quality.
  • 50A DC contactors are suitable for electric forklifts, battery trucks, tractors, excavators, brick making machines, cleaning vehicles, automotive air conditioners, communication power supplies, switch control of electronic control circuits of uninterruptible power supplies, electroplating power supplies and other systems.

Specifications

ModelATO-SZJB50A-DATO-SZJ50A-D
Contact FormNormally Closed (NC)Normally Open (NO)
Coil Rated Voltage (DC V)12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V
Contact Rated Voltage (DC V)≤60V
Contact 48V Circuit Rated Load Current (DC-1)50A
Main Contact Contact Voltage Drop Under 100A Load≤80mV
Cooling pull-in voltage (V), (20±5)℃≤70%
Cooling release operating voltage (V), (20±5)℃≤35%, ≥5%
40℃ Coil Operating Voltage Range0.8-1.2Us
Power-on Action Time10ms15ms
Power-off Release Time25ms5ms
Maximum Bounce Time of Contact Connection10ms
Maximum Bounce Time of Contact Disconnection3ms
Insulation Resistance20MΩ
Dielectric Strength50Hz/60Hz 1000VAC 1minute
Maximum Breaking Capacity of Main Contact (Power on for 5ms)1000A/5ms at 48V DC600A/5ms at 48V DC
Coil Power Consumption (W)7-154-9
Coil Temperature Rise (K)≤80≤60
Terminal Temperature Rise (K)≤65
Electrical Life20000 times
Mechanical Life300,000 times
Work SpecificationsContinuous
Contact MaterialSilver Alloy
Load Terminal TypeM5 Screw
Coil Terminal TypeM4 Screw
Testing Agency CertificationCCC, CE, FCC, RoHS


Load Characteristic Curve

50A load characteristic curve

Installation Dimension Diagram

50A DC contactor installation dimension drawing

Wiring Diagram & Temperature Rise Curve Graph

50A DC contactor wiring diagram

50A DC contactor temperature rise curve graph

Mechanical Capabilities and Usage Environment

Contact Terminal M8 Tightening Torque (Nm)≯4.5 is appropriate
Coil Lead-out M4 Tightening Torque (Nm)≯1.2 is appropriate
Ambient Temperature-25~+70℃
Relative Humidity+20℃ 98%
Vibration Frequency at Fixed Location3G, 1~50Hz, amplitude 0.5mm
Impact(60~100) times/min, acceleration ≤4g
Altitude2000 meters
Installation DirectionArbitrary
Protection LevelIP40 (equivalent to IEC60947)

Tips: Different Functions between contactor and relay

The primary function of a relay is to detect, transmit, convert, or dispose of the signal, it's on-off current is generally small. The relay is usually used in a control circuit to control the weak signal.
The primary function of a contactor is to connect or disconnect the main circuit. The main circuit refers to the one whose working situation is determined by the connection of this circuit. The concept of main circuit corresponds to the control circuit, generally, the current of a main circuit is larger than that of a control circuit.
In general, a contactor with a large capacity is equipped with an arc chute. The contact capacity of a relay will not exceed 5A, that of a midget relay may be 1A or 2A. However, the minimum contact capacity of a contactor could be 9A. Contacts of the contactor usually have three pairs of main contacts (the main contacts are normally open contacts), it also has several pairs of auxiliary contacts.
However, contacts of a relay is generally not divided into main contacts or auxiliary contacts. Sometimes, contacts of a relay are set in pairs, namely the normally open contacts and normally closed contacts are combined, while those of a contactor are not in pairs. As for specific needs, the relay will combine with other equipment into a time relay, a counter, or a pressure relay, which has additional functions, but a contactor doesn't have.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Good contactor, Fast delivery
5
Ricky
Avatar
6/13/2018 3:10 AM
Thank you for delivering in time. I am very satisfied with this 50A 24V DC contactor as well as the customer service.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

50A DC contactor with normally open and normally closed main contact, designed for direct current loads, particularly for electric vehicles, telecommunication equipment, car batteries, trains, ships, and electronic control systems.

Features

  • The DC contactor has the characteristics of small size, large load capacity, long service life and simple maintenance, and is very popular among users.
  • 50 amps contactor complies with the requirements of the ministry standards JB2286-78, JB3974-85, YD/585-92, YD/T512-92. It has been tested in the factory and by relevant testing units and meets the requirements of the ministry standards. It has been used by users for many years to satisfy users to the maximum extent. Needed, reliable quality.
  • 50A DC contactors are suitable for electric forklifts, battery trucks, tractors, excavators, brick making machines, cleaning vehicles, automotive air conditioners, communication power supplies, switch control of electronic control circuits of uninterruptible power supplies, electroplating power supplies and other systems.

Specifications

ModelATO-SZJB50A-DATO-SZJ50A-D
Contact FormNormally Closed (NC)Normally Open (NO)
Coil Rated Voltage (DC V)12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V
Contact Rated Voltage (DC V)≤60V
Contact 48V Circuit Rated Load Current (DC-1)50A
Main Contact Contact Voltage Drop Under 100A Load≤80mV
Cooling pull-in voltage (V), (20±5)℃≤70%
Cooling release operating voltage (V), (20±5)℃≤35%, ≥5%
40℃ Coil Operating Voltage Range0.8-1.2Us
Power-on Action Time10ms15ms
Power-off Release Time25ms5ms
Maximum Bounce Time of Contact Connection10ms
Maximum Bounce Time of Contact Disconnection3ms
Insulation Resistance20MΩ
Dielectric Strength50Hz/60Hz 1000VAC 1minute
Maximum Breaking Capacity of Main Contact (Power on for 5ms)1000A/5ms at 48V DC600A/5ms at 48V DC
Coil Power Consumption (W)7-154-9
Coil Temperature Rise (K)≤80≤60
Terminal Temperature Rise (K)≤65
Electrical Life20000 times
Mechanical Life300,000 times
Work SpecificationsContinuous
Contact MaterialSilver Alloy
Load Terminal TypeM5 Screw
Coil Terminal TypeM4 Screw
Testing Agency CertificationCCC, CE, FCC, RoHS


Load Characteristic Curve

50A load characteristic curve

Installation Dimension Diagram

50A DC contactor installation dimension drawing

Wiring Diagram & Temperature Rise Curve Graph

50A DC contactor wiring diagram

50A DC contactor temperature rise curve graph

Mechanical Capabilities and Usage Environment

Contact Terminal M8 Tightening Torque (Nm)≯4.5 is appropriate
Coil Lead-out M4 Tightening Torque (Nm)≯1.2 is appropriate
Ambient Temperature-25~+70℃
Relative Humidity+20℃ 98%
Vibration Frequency at Fixed Location3G, 1~50Hz, amplitude 0.5mm
Impact(60~100) times/min, acceleration ≤4g
Altitude2000 meters
Installation DirectionArbitrary
Protection LevelIP40 (equivalent to IEC60947)

Tips: Different Functions between contactor and relay

The primary function of a relay is to detect, transmit, convert, or dispose of the signal, it's on-off current is generally small. The relay is usually used in a control circuit to control the weak signal.
The primary function of a contactor is to connect or disconnect the main circuit. The main circuit refers to the one whose working situation is determined by the connection of this circuit. The concept of main circuit corresponds to the control circuit, generally, the current of a main circuit is larger than that of a control circuit.
In general, a contactor with a large capacity is equipped with an arc chute. The contact capacity of a relay will not exceed 5A, that of a midget relay may be 1A or 2A. However, the minimum contact capacity of a contactor could be 9A. Contacts of the contactor usually have three pairs of main contacts (the main contacts are normally open contacts), it also has several pairs of auxiliary contacts.
However, contacts of a relay is generally not divided into main contacts or auxiliary contacts. Sometimes, contacts of a relay are set in pairs, namely the normally open contacts and normally closed contacts are combined, while those of a contactor are not in pairs. As for specific needs, the relay will combine with other equipment into a time relay, a counter, or a pressure relay, which has additional functions, but a contactor doesn't have.

Product reviews
Good contactor, Fast delivery
5
Ricky
Avatar
6/13/2018 3:10 AM
Thank you for delivering in time. I am very satisfied with this 50A 24V DC contactor as well as the customer service.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

50A DC Reversing Contactor, 2 pole, 12V/24V/48V

ATO-DCCON-R50
$74.31
Two pole DC reversing contacor with 2 sets of switching contacts, 2NO and 2NC form, 50 amps rated load current of contact circuit, coil rated voltage with 12V/24V/48V DC for selection. Cheap price and manufacturer direct sale.

100A DC Contactor, 12V/24V/48V

ATO-DCCON-C100
$103.63
High performance 100A DC contactor with normally open or normally closed main contact type, and available with two optional auxiliary contacts. Coil rated voltage with 12V/24V/48V for selection, main contact voltage drop at 100A, not above 100mV.