3 Phase AC Voltage Sensor 5V to 500V, Output 4-20mA/RS485/0-10V

$91.58
This 3 Phase AC voltage sensor is designed for accurate and reliable measurement of three-phase AC voltages ranging from 5V to 500V. It provides versatile output options including 4-20mA current loop, 0-10V analog voltage, and RS485 digital communication, ensuring seamless integration into various monitoring and control systems. Featuring high isolation, excellent linearity, and robust protection against overloads and surges.
SKU: ATO-VOS-3AC500V
*
*
*
*
Free Shipping
Delivery date: 6-12 days

This 3 Phase AC voltage sensor is a high-performance device engineered for precise measurement and conversion of three-phase AC line voltages. It offers multiple isolated output signals, making it highly adaptable for diverse industrial automation and power system applications. Built with advanced electromagnetic isolation technology and comprehensive protective features, voltage level sensor ensures stable operation and long-term reliability in demanding environments.

Specification

ModelATO-KXT43U-VD
Installation MethodStandard DIN Rail + Flat Screw Fixation
Measurement RangeAC0-5V; AC0-50V; AC0-100V; AC0-150V; AC0-220V; AC0-250V; AC0-380V; AC0-450V; AC0-465V;AC0-500V
Output Form0~10V; RS485; 4-20mA
Auxiliary Power SupplyDC+5V, DC+12V, DC+15V, DC+24V; AC/DC 110V, AC/DC 220V; Wide Voltage: DC 6.5-36V, DC 12-36V, DC 15-36V; User Specifiable
Load CapacityVoltage Output: ≥5mA; Current Output: ≥6V
Linearity0.1%
Accuracy0.5%
Bandwidth20 Hz ~ 5 kHz
Overload Capacity2 times nominal input
Current Consumption<15mA + Output Current
Isolation Voltage1500V AC / 50Hz / 1min / 2mA
Offset Voltage≤10mV
Response TimeFollowing Output <1ms; DC Transmitting Output <250ms
Temperature Drift≤100 ppm/°C
Operating Temperature-20°C to +80°C
Storage Temperature-25°C to +85°C


Feature

  • Wide Voltage Measurement for Three-Phase Sensor: This 3 phase AC voltage measuring sensor accurately measures three-phase AC voltages from 5V up to 500V, catering to a broad spectrum of industrial power systems.
  • Versatile Output Options of the Voltage Sensor: 3 phase voltage sensor provides flexible output configurations including the standard 4-20mA current signal, 0-10V voltage signal, and RS485 digital interface for easy system integration.
  • High Isolation & Safety in the 3 Phase Sensor: This voltage measuring transducers incorporates triple-end isolation and electromagnetic isolation technology, enhancing safety and protecting connected equipment from high-voltage transients.
  • Robust Protection for the Voltage Sensor: 3 phase AC voltage transducer features 6-fold protection including input overload, output overcurrent, short-circuit, surge, overvoltage, and reverse connection protection for secure and durable operation.
  • High Accuracy & Stability of the Sensor: This voltage generating sensor achieves high measurement accuracy with low temperature drift, ensuring consistent and reliable performance across its operating temperature range.
  • Compact & Easy Installation of the 3 Phase Sensor: The compact design of this voltage sensor facilitates simple mounting via standard DIN rail or flat screw fixation, while terminal blocks allow for quick and easy wiring.

Dimension

3 phase ac voltage sensor dimensions

Wiring Diagram
3 phase ac voltage sensor wiring diagram

Signal KXT43U-VD (three-phase four-wire star connection / power supply DC24V)

3 phase ac voltage sensor wiring diagram

Signal KXT43U-VD (three-phase three-wire delta connection / power supply DC24V)

KXT43U-VD (three-phase three-wire star connection / power supply DC24V)

3 phase ac voltage sensor wiring diagram

Signal KXT43U-VD (three-phase four-wire star connection / power supply 220V)

3 phase ac voltage sensor wiring diagram

Signal KXT43U-VD (three-phase three-wire delta connection / power supply 220V)

KXT43U-VD (three-phase three-wire star connection / power supply 220V)

5 Tips for 3 Phase AC Voltage Sensor

  1. Ensure the selected voltage measurement range of the 3 Phase AC voltage sensor adequately covers the system's maximum operating voltage, including potential surges.
  2. For long-distance transmission, the 4-20mA output from the voltage sensor is generally preferred due to its inherent noise immunity.
  3. When using the RS485 interface on this voltage detection sensor, proper termination and adherence to communication protocol specifications are crucial for reliable data exchange.
  4. Verify that the auxiliary power supply voltage matches the 3 phase voltage generating sensor's requirements before energizing the device.
  5. For optimal performance and safety, install the voltage transducer in a well-ventilated environment within its specified operating temperature range.
Product reviews
Response time requirements
5
Aker
Avatar
5/25/2026 12:11 AM
I want to monitor the voltage drop of a 120VAC line within the first 200 milliseconds. The response time (subsequent output <1 millisecond) seems to meet our requirements. Can the ATO-KXY43-VD sensor achieve this function?
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, the response time of this product is within 200ms, which does not meet your requirement of less than 1ms.
No separate power supply required
5
Elsali
Avatar
10/16/2026 1:28 AM
Does the 3-phase AC voltage sensor support three-phase AC power supply and not require a separate power supply for metering functions?
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, this 3-phase AC voltage sensor requires an auxiliary power supply.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

This 3 Phase AC voltage sensor is a high-performance device engineered for precise measurement and conversion of three-phase AC line voltages. It offers multiple isolated output signals, making it highly adaptable for diverse industrial automation and power system applications. Built with advanced electromagnetic isolation technology and comprehensive protective features, voltage level sensor ensures stable operation and long-term reliability in demanding environments.

Specification

ModelATO-KXT43U-VD
Installation MethodStandard DIN Rail + Flat Screw Fixation
Measurement RangeAC0-5V; AC0-50V; AC0-100V; AC0-150V; AC0-220V; AC0-250V; AC0-380V; AC0-450V; AC0-465V;AC0-500V
Output Form0~10V; RS485; 4-20mA
Auxiliary Power SupplyDC+5V, DC+12V, DC+15V, DC+24V; AC/DC 110V, AC/DC 220V; Wide Voltage: DC 6.5-36V, DC 12-36V, DC 15-36V; User Specifiable
Load CapacityVoltage Output: ≥5mA; Current Output: ≥6V
Linearity0.1%
Accuracy0.5%
Bandwidth20 Hz ~ 5 kHz
Overload Capacity2 times nominal input
Current Consumption<15mA + Output Current
Isolation Voltage1500V AC / 50Hz / 1min / 2mA
Offset Voltage≤10mV
Response TimeFollowing Output <1ms; DC Transmitting Output <250ms
Temperature Drift≤100 ppm/°C
Operating Temperature-20°C to +80°C
Storage Temperature-25°C to +85°C


Feature

  • Wide Voltage Measurement for Three-Phase Sensor: This 3 phase AC voltage measuring sensor accurately measures three-phase AC voltages from 5V up to 500V, catering to a broad spectrum of industrial power systems.
  • Versatile Output Options of the Voltage Sensor: 3 phase voltage sensor provides flexible output configurations including the standard 4-20mA current signal, 0-10V voltage signal, and RS485 digital interface for easy system integration.
  • High Isolation & Safety in the 3 Phase Sensor: This voltage measuring transducers incorporates triple-end isolation and electromagnetic isolation technology, enhancing safety and protecting connected equipment from high-voltage transients.
  • Robust Protection for the Voltage Sensor: 3 phase AC voltage transducer features 6-fold protection including input overload, output overcurrent, short-circuit, surge, overvoltage, and reverse connection protection for secure and durable operation.
  • High Accuracy & Stability of the Sensor: This voltage generating sensor achieves high measurement accuracy with low temperature drift, ensuring consistent and reliable performance across its operating temperature range.
  • Compact & Easy Installation of the 3 Phase Sensor: The compact design of this voltage sensor facilitates simple mounting via standard DIN rail or flat screw fixation, while terminal blocks allow for quick and easy wiring.

Dimension

3 phase ac voltage sensor dimensions

Wiring Diagram
3 phase ac voltage sensor wiring diagram

Signal KXT43U-VD (three-phase four-wire star connection / power supply DC24V)

3 phase ac voltage sensor wiring diagram

Signal KXT43U-VD (three-phase three-wire delta connection / power supply DC24V)

KXT43U-VD (three-phase three-wire star connection / power supply DC24V)

3 phase ac voltage sensor wiring diagram

Signal KXT43U-VD (three-phase four-wire star connection / power supply 220V)

3 phase ac voltage sensor wiring diagram

Signal KXT43U-VD (three-phase three-wire delta connection / power supply 220V)

KXT43U-VD (three-phase three-wire star connection / power supply 220V)

5 Tips for 3 Phase AC Voltage Sensor

  1. Ensure the selected voltage measurement range of the 3 Phase AC voltage sensor adequately covers the system's maximum operating voltage, including potential surges.
  2. For long-distance transmission, the 4-20mA output from the voltage sensor is generally preferred due to its inherent noise immunity.
  3. When using the RS485 interface on this voltage detection sensor, proper termination and adherence to communication protocol specifications are crucial for reliable data exchange.
  4. Verify that the auxiliary power supply voltage matches the 3 phase voltage generating sensor's requirements before energizing the device.
  5. For optimal performance and safety, install the voltage transducer in a well-ventilated environment within its specified operating temperature range.
Product reviews
Response time requirements
5
Aker
Avatar
5/25/2026 12:11 AM
I want to monitor the voltage drop of a 120VAC line within the first 200 milliseconds. The response time (subsequent output <1 millisecond) seems to meet our requirements. Can the ATO-KXY43-VD sensor achieve this function?
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, the response time of this product is within 200ms, which does not meet your requirement of less than 1ms.
No separate power supply required
5
Elsali
Avatar
10/16/2026 1:28 AM
Does the 3-phase AC voltage sensor support three-phase AC power supply and not require a separate power supply for metering functions?
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, this 3-phase AC voltage sensor requires an auxiliary power supply.
Only registered users can write reviews
Customers who bought this item also bought

3 Phase AC Current Transducer 0.5A/1A/2A/5A/10A/20A/50A to 80A

ATO-CUS-3AC80
$161.39
AC current transducer is a special current sensor for 3 phase AC current measurement. Three phase current transducer adopts epoxy resin pouring sealant to ensure the stability of components, with 0.5%FS accuracy, three output signals 4-20mA/0-20mA/0-5V/0-10V, power supply DC 5V/12V/24V, fixed installation. 3 phase AC current transducer is widely used for real-time monitoring of power grid AC current.

3 Phase AC Voltage Transducer 10V to 500V, Output 0-5V/4-20mA/0-20mA

ATO-VOS-3AC500
$177.78
3 phase AC voltage transducer is a special voltage sensor for three-phase AC voltage measurement. Voltage transducer has a measuring range from AC 10V to 500V, supply voltage DC 12V/24V, output signal DC 0-5V/0-20mA/4-20mA. 3 phase voltage transducer is mainly used for power monitoring, power control and dispatching systems in petroleum, coal, metallurgy, railway and other industries.