3 hp/2.2kW three-phase induction motor features 2 poles, 2840rpm rated speed and 7.4Nm nominal torque, with working voltage of 380V 50Hz. Cheap 3-phase asynchronous motor has outstanding performance in the price, mantenance, reliability, durability and operation.
SKU: ATO-IM-22002P
Free Shipping
Delivery date: 6-12 days

This is a totally enclosed fan cooled 3-phase 4-pole induction motor with rated output 3 hp, rated speed 28740rpm in foot mounting. It can widely used in various kinds of general purpose machineries like fans, pumps, compressors, machine tools, transportation, etc.

3hp Induction Motor Specification

BasicsModelATO-Y2-90L-2
Design StandardIEC
Weight24kg
Frame Type90L
MountingHorizontal Foot Mounting (B3)
Wiring MethodOutput≤4hp (3kW), Y connection
Output≥5.5hp (4kW), Delta connection
Degree of protectionIP54/IP55
Insulation ClassClass F
CoolingTEFC (compliance to IC 411 code of IEC 60034-6)
Technical ParametersNominal Output3.0hp or 2.2kW
Pole Number2-pole
Nominal Speed2840rpm
Frequency50Hz
Nominal Voltage380V (Y connection by default) / 220V (Change Y to Δ connection on your own)
Nominal Current (full load)4.85A/8.4A
Efficiency81.0%
Power Factor( cosφ)0.85
Nominal Torque (Tn)7.4Nm
Locked Rotor Torque/Nominal Torque (TST/Tn)2.2
Maximum Torque/Nominal Torque (Tmax/Tn)2.3
Locked Rotor Current/Nominal Current (IST/In)7.0
Noise Level72dB/(A)
EnvironmentAmbient Temperature-15℃+40℃
AltitudeLess than 1000m above sea level

3-phase Induction Motor Dimensions
3-phase AC induction motor dimensions

Frame TypeMounting Dimensions (mm)Overall Dimensions
AA/2BCDEFGHKABACADHDL
90L140701255624508209010180195155250345

Wiring Diagrams (Three-phase squirrel-cage induction motor)
3 phase induction motor wiring connection diagram

Details

2200W AC Induction Motor Details

Tips: Three-phase induction motor’s speed control method
Three-phase induction motor speed is calculated: n = 60f (1-s) / p
It is seen from the above formula that changing power supply frequency f, motor pole pairs p and slips can achieve the purpose of changing the rotate speed. From the perspective of the nature of speed control, different speed control methods are nothing more than changing the synchronous speed of alternating current motor or not changing the synchronous speed. The speed control method of not changing the synchronous speed is widely used in manufacturing machinery including series resistance in the rotor of wound-type motor, chopper, cascade and electromagnetic slip clutch, hydraulic coupling, oil film clutch etc. Changing the synchronous speed consists of multi-speed motor of stator pole pairs, stator voltage and frequency conversion etc.
In views of energy consumed at speed control, there are two types including high-efficiency speed control and low-efficiency speed control. High-efficiency speed control refers to constant slip or non-slip loss, such as multi-speed motor, frequency control and control method of recovering the slip loss (for instance cascade speed control etc.). Slip loss speed control method is inefficient for example energy loss occur in the rotor circuit  by the speed control method of series resistance in the rotator; Energy loss happens in the clutch coil by the speed control method of electromagnetic clutch; energy loss takes place in the hydraulic couplers oil by the speed control method of hydrodynamic coupling. Generally speaking, the slip loss increases with the expansion of speed range. If the speed range is not large, the energy loss will be very small.

3 Phase Induction Motor Wiring

In this video, ATO takes a 1hp (0.75kW) 220V/380V induction motor as example to explain the motor wiring. ATO first changes the wiring of induction motor from star connection to delta connection. When the induction motor is connected in delta connection, the rated voltage of motor is 220V, and when connected in star connection, the rated voltage is 380V. To demonstrate this change clearly, the induction motor is also connected to ATO 1-phase in 3-phase out VFD and it runs normally under the control of VFD.

Three-phase Motor to Single-phase (380V to 220V)

If a frequency converter is beyond your budget or availability, one way to run a three-phase motor from single-phase power is to use capacitors. In this tutorial, the step-by-step process of adapting a motor for single-phase operation is demonstrated by showing the correct capacitor sizing and wiring configuration.

Two-wire Control Wiring of VFD Forward Motor with Push Button

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

Three-phase Motor Forward and Reverse Wiring and PLC Programming

To achieve forward and reverse rotation of a three-phase asynchronous motor, you only need to swap the positions of any two phase wires. (Single-phase asynchronous motors need to be wired according to the instructions to achieve forward and reverse rotation).

Product reviews
Purchased this 3 horse power induction motor to replace my old one
5
Arthur
Avatar
7/11/2019 7:26 PM
I purchased this 3 horse power induction motor to replace my old one. It is very easy to wire this motor via the diagram that comes with the motor. Fit my machine perfect. Runs really smooth.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

This is a totally enclosed fan cooled 3-phase 4-pole induction motor with rated output 3 hp, rated speed 28740rpm in foot mounting. It can widely used in various kinds of general purpose machineries like fans, pumps, compressors, machine tools, transportation, etc.

3hp Induction Motor Specification

BasicsModelATO-Y2-90L-2
Design StandardIEC
Weight24kg
Frame Type90L
MountingHorizontal Foot Mounting (B3)
Wiring MethodOutput≤4hp (3kW), Y connection
Output≥5.5hp (4kW), Delta connection
Degree of protectionIP54/IP55
Insulation ClassClass F
CoolingTEFC (compliance to IC 411 code of IEC 60034-6)
Technical ParametersNominal Output3.0hp or 2.2kW
Pole Number2-pole
Nominal Speed2840rpm
Frequency50Hz
Nominal Voltage380V (Y connection by default) / 220V (Change Y to Δ connection on your own)
Nominal Current (full load)4.85A/8.4A
Efficiency81.0%
Power Factor( cosφ)0.85
Nominal Torque (Tn)7.4Nm
Locked Rotor Torque/Nominal Torque (TST/Tn)2.2
Maximum Torque/Nominal Torque (Tmax/Tn)2.3
Locked Rotor Current/Nominal Current (IST/In)7.0
Noise Level72dB/(A)
EnvironmentAmbient Temperature-15℃+40℃
AltitudeLess than 1000m above sea level

3-phase Induction Motor Dimensions
3-phase AC induction motor dimensions

Frame TypeMounting Dimensions (mm)Overall Dimensions
AA/2BCDEFGHKABACADHDL
90L140701255624508209010180195155250345

Wiring Diagrams (Three-phase squirrel-cage induction motor)
3 phase induction motor wiring connection diagram

Details

2200W AC Induction Motor Details

Tips: Three-phase induction motor’s speed control method
Three-phase induction motor speed is calculated: n = 60f (1-s) / p
It is seen from the above formula that changing power supply frequency f, motor pole pairs p and slips can achieve the purpose of changing the rotate speed. From the perspective of the nature of speed control, different speed control methods are nothing more than changing the synchronous speed of alternating current motor or not changing the synchronous speed. The speed control method of not changing the synchronous speed is widely used in manufacturing machinery including series resistance in the rotor of wound-type motor, chopper, cascade and electromagnetic slip clutch, hydraulic coupling, oil film clutch etc. Changing the synchronous speed consists of multi-speed motor of stator pole pairs, stator voltage and frequency conversion etc.
In views of energy consumed at speed control, there are two types including high-efficiency speed control and low-efficiency speed control. High-efficiency speed control refers to constant slip or non-slip loss, such as multi-speed motor, frequency control and control method of recovering the slip loss (for instance cascade speed control etc.). Slip loss speed control method is inefficient for example energy loss occur in the rotor circuit  by the speed control method of series resistance in the rotator; Energy loss happens in the clutch coil by the speed control method of electromagnetic clutch; energy loss takes place in the hydraulic couplers oil by the speed control method of hydrodynamic coupling. Generally speaking, the slip loss increases with the expansion of speed range. If the speed range is not large, the energy loss will be very small.

Product reviews
Purchased this 3 horse power induction motor to replace my old one
5
Arthur
Avatar
7/11/2019 7:26 PM
I purchased this 3 horse power induction motor to replace my old one. It is very easy to wire this motor via the diagram that comes with the motor. Fit my machine perfect. Runs really smooth.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

3 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

GK3000-CT0022
$446.92
1-phase 220V to 3-phase 380V VFD, 3 hp variable frequency drive for AC motor speed control at 50Hz/ 60Hz input frequency. 5.1 amps rated current, three phase 400V/ 415V AC output are customized.

5 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

GK3000-CT0037
$473.54
Best 5 hp variable frequency drive at low price. Single phase 220 volt input to three phase 380 volt output VFD for AC motor speed control, IP20, RS485 enabled, V/F and sensorless vector control mode.

5 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0037
$294.31
5hp variable frequency drive, single phase to three phase VFD, 17 amps, RS485 enabled, shipping weight 4kg, manufacturer direct sale.