3 Pole Molded Case Circuit Breaker, 100A/ 150A/ 200A/ 250A

$139.14
3 pole molded case circuit breaker at lower price, easy to install. Mccb breaker is capable of protecting the system against short circuit current up to 50kA. It has 1500 times' electrical life and 8500 times' mechanical life. Molded circuit breaker is used to distribute electric energy and protect circuits and electrical equipment from overload or short circuit.
SKU: ATO-MCCB-2503P
*
Free Shipping
Delivery date: 6-12 days

Max. rated current 250 amp mccb with 380/415V AC, 50Hz/ 60Hz rated voltage, 100A/ 150A/ 200A/ 250A rated current are optional. 3 pole mccb offers stable and reliable function, beautiful appearance, small size and long service life.

Molded Case Circuit Breaker Information

  • Model: ATO-MCCB-ABE-203b
  • Rated Current: 250 amp
  • Rated Voltage: 380/415V AC, 50Hz/ 60Hz
  • Number of poles: Three pole
  • 50 kA short circuit interrupting capacity

Specification

Standard CertificationsIEC60947GB14048
Electrical ParametersModelATO-ABE-203b
Rated Current100A, 125A, 150A, 175A, 200A, 225A, 250A (contact us, the current can be chosen)
Numbers of Poles3 Pole
Rated Operating Voltage400V
Rated Insulated Voltage (Ui)800V
Rated Frequency50Hz/ 60Hz
Ultimate Short Circuit Breaking Capacity, IcuDC125V15kA
250V10kA
AC 50Hz/ 60Hz230V35kA
380V18kA
415V18kA
440V18kA
480V10kA
600V7.5kA
Mechanical ParametersElectrical Life1500 times
Mechanical Life8500 times
Protection DegreeIP20
Operating Temperature-25℃~+50℃
Weight1.5kg

Dimension (Unit: mm)

Diemension of molded case circuit breaker      Diemension of molded case circuit breaker 1 Diemension of molded case circuit breaker 2

ModelDimensionsMounting Dimensions
CC1EFGG1HH1H2H3H4H5LL1L2WW1W2ABΦd
ATO-ABE-203b102154502223108611024544.516521514412042140381687

Details

3 Pole Molded Case Circuit Breaker,100A-250A Details

Tips:  The Characteristics of Molded Case Circuit Breaker.

1. Current limiting and breaking capacity

When the circuit breaker is short-circuited, the contacts quickly open to produce an arc, which is equivalent to inserting a rapidly increasing arc resistance in the line, thus limiting the increase of the fault current. The shorter the opening time of the circuit breaker, the closer Ics is to Icu, and the better the current limiting effect. It can also greatly reduce the electromagnetic effect, electric effect and thermal effect caused by short-circuit current on the circuit breaker and electrical equipment, and prolong the circuit breaker's service life.

2. Short circuit protection
Short-circuit protection is the instantaneous tripping of short-circuit. Pay attention to adjusting the protection setting value in time after the load changes, to prevent the setting value from being too small and frequent tripping that affects the quality of power supply, or the setting value is too high to prevent effective protection of lines and equipment.

3. Overload delay protection
Overload delay protection means that the load current exceeds the limit of the equipment and there is a danger of burning the equipment. The protection device can cut off the power supply within a certain period of time. Overload has a process of heat accumulation, and the protection action does not need to be too fast. For short-time overcurrent, the protection should not act.

4. Isolation function
The isolation function is to require that the leakage current after the circuit breaker is disconnected will not cause harm to people and equipment. After multiple short-circuit trips, the performance of the switch will decrease and the leakage current will increase. For the human body, a leakage current of less than 30mA is a safe leakage current, and in a harsh environment, a leakage current exceeding 300mA for more than 2 hours may cause a phase-to-ground short circuit due to insulation damage and cause a fire.

5. Leakage Protection
There are two types of leakage devices, thermal magnetic type and electronic type. In comparison, electronic leakage devices have the advantages of small size, high precision and high sensitivity, but their anti-interference ability is poor. At present, electronic leakage protectors dominate the mainstream. When the leakage current reaches the set value, the executive circuit receives the induced voltage signal on the secondary side of the zero-sequence current transformer, drives the conversion contact to output the leakage protection signal, and causes the trip unit to act and cut off the power supply.

Types of Circuit Breakers

In this video, we'll take a closer look at the meaning behind these abbreviations and explain the types of circuit breakers they represent. By understanding the different types of circuit breakers on the market, you can make an informed decision and choose the right type for your specific requirements, thereby enhancing the protection of your electrical infrastructure.

Isolator vs Circuit Breaker

Although isolators and circuit breakers have similar functions in a circuit, they are two separate entities. This video explains you the difference between the two devices in terms of working, features, operation, affordability, etc. You can choose between them based on your specific requirements.

Product reviews
Is this circuit breaker reversible?
5
Joe
Avatar
4/27/2022 8:04 PM
Is this circuit breaker reversible? Or is there a positive and a negative end? I'm unsure which end I should connect to the positive battery terminal. I will appreciate you if you answer my questions.
Was this review helpful? Yes No (0/0)
ATO Responded
It's an inline fuse block, either direction will work. Positive in one end, positive out of the other.
Extremely satisfied
5
Sapello
Avatar
5/30/2022 1:12 AM
This 3P mcccb is exactly as ordered and worked flawlessly, with great price and excellent delivery service!
Was this review helpful? Yes No (0/0)
3-pole mccb performing well
5
appyshoer
Avatar
3/27/2023 9:36 PM
I bought these 3p molded case circuit breakers for my new system. So far so good.  It does what it is supposed to do. Worked perfectly!
Was this review helpful? Yes No (0/0)
The user experience is quite good
5
Wenzel
Avatar
11/26/2024 1:26 AM
The circuit breaker operates stably without any abnormalities under high load conditions. Its design meets the quality requirements of industrial grade. The indicator lights displayed on the panel are clear and easy to understand, making fault indication and reset operations very convenient.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Max. rated current 250 amp mccb with 380/415V AC, 50Hz/ 60Hz rated voltage, 100A/ 150A/ 200A/ 250A rated current are optional. 3 pole mccb offers stable and reliable function, beautiful appearance, small size and long service life.

Molded Case Circuit Breaker Information

  • Model: ATO-MCCB-ABE-203b
  • Rated Current: 250 amp
  • Rated Voltage: 380/415V AC, 50Hz/ 60Hz
  • Number of poles: Three pole
  • 50 kA short circuit interrupting capacity

Specification

Standard CertificationsIEC60947GB14048
Electrical ParametersModelATO-ABE-203b
Rated Current100A, 125A, 150A, 175A, 200A, 225A, 250A (contact us, the current can be chosen)
Numbers of Poles3 Pole
Rated Operating Voltage400V
Rated Insulated Voltage (Ui)800V
Rated Frequency50Hz/ 60Hz
Ultimate Short Circuit Breaking Capacity, IcuDC125V15kA
250V10kA
AC 50Hz/ 60Hz230V35kA
380V18kA
415V18kA
440V18kA
480V10kA
600V7.5kA
Mechanical ParametersElectrical Life1500 times
Mechanical Life8500 times
Protection DegreeIP20
Operating Temperature-25℃~+50℃
Weight1.5kg

Dimension (Unit: mm)

Diemension of molded case circuit breaker      Diemension of molded case circuit breaker 1 Diemension of molded case circuit breaker 2

ModelDimensionsMounting Dimensions
CC1EFGG1HH1H2H3H4H5LL1L2WW1W2ABΦd
ATO-ABE-203b102154502223108611024544.516521514412042140381687

Details

3 Pole Molded Case Circuit Breaker,100A-250A Details

Tips:  The Characteristics of Molded Case Circuit Breaker.

1. Current limiting and breaking capacity

When the circuit breaker is short-circuited, the contacts quickly open to produce an arc, which is equivalent to inserting a rapidly increasing arc resistance in the line, thus limiting the increase of the fault current. The shorter the opening time of the circuit breaker, the closer Ics is to Icu, and the better the current limiting effect. It can also greatly reduce the electromagnetic effect, electric effect and thermal effect caused by short-circuit current on the circuit breaker and electrical equipment, and prolong the circuit breaker's service life.

2. Short circuit protection
Short-circuit protection is the instantaneous tripping of short-circuit. Pay attention to adjusting the protection setting value in time after the load changes, to prevent the setting value from being too small and frequent tripping that affects the quality of power supply, or the setting value is too high to prevent effective protection of lines and equipment.

3. Overload delay protection
Overload delay protection means that the load current exceeds the limit of the equipment and there is a danger of burning the equipment. The protection device can cut off the power supply within a certain period of time. Overload has a process of heat accumulation, and the protection action does not need to be too fast. For short-time overcurrent, the protection should not act.

4. Isolation function
The isolation function is to require that the leakage current after the circuit breaker is disconnected will not cause harm to people and equipment. After multiple short-circuit trips, the performance of the switch will decrease and the leakage current will increase. For the human body, a leakage current of less than 30mA is a safe leakage current, and in a harsh environment, a leakage current exceeding 300mA for more than 2 hours may cause a phase-to-ground short circuit due to insulation damage and cause a fire.

5. Leakage Protection
There are two types of leakage devices, thermal magnetic type and electronic type. In comparison, electronic leakage devices have the advantages of small size, high precision and high sensitivity, but their anti-interference ability is poor. At present, electronic leakage protectors dominate the mainstream. When the leakage current reaches the set value, the executive circuit receives the induced voltage signal on the secondary side of the zero-sequence current transformer, drives the conversion contact to output the leakage protection signal, and causes the trip unit to act and cut off the power supply.

Product reviews
Is this circuit breaker reversible?
5
Joe
Avatar
4/27/2022 8:04 PM
Is this circuit breaker reversible? Or is there a positive and a negative end? I'm unsure which end I should connect to the positive battery terminal. I will appreciate you if you answer my questions.
Was this review helpful? Yes No (0/0)
ATO Responded
It's an inline fuse block, either direction will work. Positive in one end, positive out of the other.
Extremely satisfied
5
Sapello
Avatar
5/30/2022 1:12 AM
This 3P mcccb is exactly as ordered and worked flawlessly, with great price and excellent delivery service!
Was this review helpful? Yes No (0/0)
3-pole mccb performing well
5
appyshoer
Avatar
3/27/2023 9:36 PM
I bought these 3p molded case circuit breakers for my new system. So far so good.  It does what it is supposed to do. Worked perfectly!
Was this review helpful? Yes No (0/0)
The user experience is quite good
5
Wenzel
Avatar
11/26/2024 1:26 AM
The circuit breaker operates stably without any abnormalities under high load conditions. Its design meets the quality requirements of industrial grade. The indicator lights displayed on the panel are clear and easy to understand, making fault indication and reset operations very convenient.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

100 hp (75 kW) Soft starter, 150 A, 3ph 240v/400v/480v

GS-075
$619.62
High quality 100 hp soft starter, 75 kW three phase 240v, 400v, 480v for selection, control motor in soft start & soft stop, direct sale by manufacturer.

150 hp (110 kW) Soft starter, 230 A, 3ph 240v/415v/480v

GS-110
$1,219.51
Affordable 150 hp soft starter, 110 kW three phase 240v, 415v, 480v, control motor in soft start & soft stop, selling by manufacturer directly with wholesale price.

330 amp 3 phase AC Magnetic Contactor, 24V/110V/220V Coil

ATO-ACCON-330A
$685.65
Favorable price 3 pole 3 phase AC magnetic contactor with rated current up to 330A, 24V/110V/220V coils, is suitable for switching and controlling electric motors for industrial applications. This AC contactor relay has a wide selection of contact form to choose from.